5.5 Checking Operation after Installation and Preparing the IDD for Use
C141-E133-02EN
5-13
5.
The saved value of the MODE SELECT parameter is assumed as the initial
value of each parameter after the power-on, the RESET condition, or the
BUS DEVICE RESET message. The INIT can change the parameter value
temporary (actively) at any timing by issuing the MODE SELECT or
MODE SELECT EXTENDED command with specifying "0" to the SP bit in
the CDB.
(1)
Error recovery parameter
The following parameters are used to control operations such as IDD internal error recovery:
a.
Read/write error recovery parameters (page code = 1)
Parameter
Default value
• AWRE:
• ARRE:
• TB:
• EER:
• PER:
• DCR:
Automatic alternate block allocation at Write
operation
Automatic alternate block allocation at read
operation
Uncorrectable data transfer to the INIT
Immediate correction of correctable error
Report of recovered error
Suppression of ECC error correction
1 (enabled)
1 (enabled)
1 (enabled)
1 (enabled)
0 (disabled)
0 (Correction is
enabled.)
• Retry count at read operation
• Retry count at write operation
• Recovery time limit
63
63
30 sec
b. Verify error recovery parameters (page code = 7)
Parameter
Default value
• ERR:
• PER:
• DTE:
• DCR:
Immediate correction of recoverable error
Report of recovered error
Stop of command processing at successful
error recovery
Suppression of ECC error correction
1 (enabled)
0 (disabled)
0 (Processing is
continued.)
0 (Correction is
enabled.)
• Retry count at verification
63
c.
Additional error recovery parameters (page code = 21)
Parameter
Default value
• Retry count at seek error
15
Содержание MAN3367FC - Enterprise 36.7 GB Hard Drive
Страница 1: ...C141 E133 02EN MAN3735FC SERIES MAN3367FC SERIES DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 4: ......
Страница 6: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 21: ...Contents C141 E133 02EN xv Glossary GL 1 Abbreviations AB 1 Index IN 1 ...
Страница 24: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 66: ...Installation Requirements 4 10 C141 E133 02EN Figure 4 10 SCA2 type connector ...
Страница 110: ...Principle of Operation 8 8 C141 E133 02EN Figure 8 3 Block diagram of read write circuit ...
Страница 116: ...This page is intentionally left blank ...
Страница 132: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 144: ...This page is intentionally left blank ...
Страница 146: ...This page is intentionally left blank ...
Страница 147: ......
Страница 148: ......