C141-E128-01EN
5 - 2
(2)
Unpackaging
a) Use a flat work area. Check that the "This Side Up" sign side is up. Handle the package on
soft material such as a rubber mat, not on hard material such as a desk.
b) Be careful not to give excess pressure to the internal unit when removing cushions.
c) Be careful not to give excess pressure to the PCAs and interface connector when removing the
drive from the antistatic bag.
d) Do not remove the sealing label or cover of the DE and screws.
(3)
Installation/removal/replacement
a) Do not attempt to connect or disconnect connections when power is on. The only pin settings
that may be altered are pins 9, 10 (Write Protect) in CN2. (MP model)
b) Do not move the drive when power is turned on or until the drive completely stops (for 30
seconds) after power is turned off.
c) Place and keep removed screws and other parts where they will not get lost or damaged.
d) Keep a record of all maintenance work for replacing.
(4)
Packaging
a) Store the drive in an antistatic vinyl pack.
b) It is recommended to use the same cushions and packages as those at delivery. If those at
delivery cannot be used, use a package with shock absorption so that the drive is free from
direct shocks. In this case, fully protect the PCAs and interface connector so that they are not
damaged.
c) Indicate "This Side Up" and "Handle With Care" on the outside of the package so that it is not
turned over.
(5)
Delivery
a) When delivering the drive, provide packaging and do not turn it over.
b) Minimize the delivery distance after unpacking and avoid shocks and vibrations with
cushions. For the carrying direction at delivery, use one of the mount allowable directions in
Subsection 4.2.2 (vertical direction is recommended).
(6)
Storage
a) Provide vaporproof packaging for storage.
b) The storage environment must satisfy the requirements specified in Subsection 2.1.3 when the
drive is not operating.
Содержание MAN3184MC - Enterprise 18.4 GB Hard Drive
Страница 18: ...This page is intentionally left blank ...
Страница 28: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 52: ...This page is intentionally left blank ...
Страница 66: ...C141 E128 01EN 4 14 Figure 4 17 External operator panel connector CN2 ...
Страница 88: ...C141 E128 01EN 5 14 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A 60 ...
Страница 124: ...8 8 C141 E128 01EN Figure 8 3 Block diagram of read write circuit ...
Страница 130: ...This page is intentionally left blank ...
Страница 134: ...This page is intentionally left blank ...
Страница 140: ...This page is intentionally left blank ...
Страница 145: ......