En-30
• When the lamp reaches the end of its service life, the image becomes dark and the colors lose their vividness. When this
happens, change the lamp unit.
• When the “Approaching Recommended Lamp Life!” message appears, change the lamp unit.
• After removing the old lamp unit, handle with care to avoid breakage. Dispose of as industrial waste.
• Be sure to initialize the lamp timer after changing the lamp unit.
WARNING
• Do not remove any screws other than those specified ( mark).
The high voltage and high temperature inside the projector may lead to electric shock or burns if touched.
• When changing the lamp unit, be sure to replace with a new lamp unit. Use of a used or second-hand lamp unit may lead
to breakage or failure of the lamp.
Changing the Lamp
Allow the lamp to cool for more than 1 hour after switching off the power before changing.
Remove the 1 screw ( mark)
and remove the lamp cover
from the projector.
For safety reasons, the safety devices are enabled
when changing the lamp to shut off the power.
Press the POWER button and
remove the power connector
from the power terminal.
1
2
Remove power connector
Changing the Lamp