En-13

CLEANING THE PLASMA AIR CLEANING FILTER

 CAUTION!

 WARNING!

Make sure the plasma filter unit is properly mounted before cleaning or performing other tasks
on it. If the unit is not properly mounted, it could fall off and cause damage or injury.

You can be injured if you touch the heat exchanger when removing or installing the plasma filter
unit. Do not insert your fingers between the plasma filter unit and the heat exchanger.

Before cleaning the plasma filter unit, be sure to turn off the power supply to the air conditioner.
Electric shock may result.

Regarding the Air Cleaning check function

 This function is illustrated by the flashing of the AIR CLEAN Indicator Lamp (orange), indicating that the unit requires

maintenance.

After Air Cleaning Mode has been in use for approximately 400 hours, the AIR CLEAN Indicator Lamp (orange) will begin
to slowly flash (approximately once every 7 seconds). When this occurs, the unit requires maintenance.

After Air Cleaning Mode has been in use for approximately 500 hours, the AIR CLEAN Indicator Lamp (orange) will begin
to flash quickly (approximately once every 3 seconds). At this point, Air Cleaning will cease functioning. Please carry out
appropriate maintenance for the unit.

Please carry out unit maintenance every 6 months.

If a squeaking or chirping sound is heard,  unit maintenance needs to be carried out, even if the AIR CLEAN Indicator Lamp
(orange) is not flashing.

Cleaning the dust collection unit

1. Open the intake grille and remove the air

filter on the right.

Please consult the instructions for cleaning the air
filter on page 12.

4. Wash with water and dry.

1

Soak the plasma filter unit in warm water (104 to
113˚F) for 10 to 15 minutes. If the plasma filter unit is
extremely dirty, extremely dilute a mild synthetic laun-
dry detergent (low alkalinity or isotope detergent) to
15 times the standard concentration and allow the
plasma filter unit to soak in it.

2

Gently move up and down and to the right and left. A
soft sponge can also be used to wipe the surface.

3

Rinse with clean water.

4

Shake the plasma filter unit to drain off the water. (If
the plasma filter unit is extremely dirty, repeat Steps

1

 through 

4

 two or three more times.)

5

Place the plasma filter unit in the shade and allow it
to dry completely.

 Only use a mild synthetic laundry detergent (low

alkalinity or isotope detergent).

● 

Never disassemble the plasma filter unit.

● 

Never soak the plasma filter unit in hot water.

● 

Never wipe the plasma filter unit with a scrub brush

or other hard or abrasive items. This will damage
the honey comb filter.

 Never insert a brush into the inside of plasma filter

unit for washing. This will damage the internal parts
and cause malfunctioning of the plasma filter unit.

 Never use dryer or other device to blow hot air on

the plasma filter unit. This will cause deformation
or other damage.

 Before re-installing the unit, please wait until it is

completely dry. If the unit is installed when still wet
and then put into operation, the OPERATION Indi-
cator Lamp (red) and the TIMER Indicator Lamp
(green) will flash and Air Cleaning will stop.

handle

2. Remove the dust collection unit.

Securely grasp the dust collection unit by the handle and
pull it out (as shown by the arrow).
(The above figure is only for reference, so the intake grille
is not included).

3. Remove the air cleaning & deodorizing fil-

ter from the cleaning unit.

1

Open the filter case at the rear of cleaning unit.

2

Remove the air cleaning & deodorizing filter.

Claw

Claw

Filter case

Air cleaning &
deodorizing filter

Содержание Inverter Halcyon AOU24RLQ

Страница 1: ...ERENCE FUJITSU GENERAL LIMITED P N9315345073 01 OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO English Français Español Indoor Unit ASU24RLQ Outdoor Unit AOU24RLQ HEAT COOLING MODEL REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE ...

Страница 2: ...Y T U V W Q X d c e _ f Z WIRED REMOTE CONTROL UNIT OPTION The optional wired remote control unit model No UTB UUB can be used When you use wired remote control unit there are following different points as compared with using wireless remote control unit The additional functions for wired ones Weekly timer Temperature set back timer The restricted functions for wired ones QUIET can t be selected i...

Страница 3: ...SANCE ABSORBÉE 2 31 kW INTENSITÉ 10 1 A CHAUFFAGE PUISSANCE FRIGORIFIQUE 27 600 BTU h PUISSANCE ABSORBÉE 2 47 kW INTENSITE 10 8 A SPECIFICATIONS POWER SUPPLY 208 230 V 60 Hz COOLING CAPACITY 24 200 BTU h INPUT POWER 2 31 kW CURRENT 10 1 A HEATING CAPACITY 27 600 BTU h INPUT POWER 2 47 kW CURRENT 10 8 A MODEL INDOOR UNIT MODÈLE UNIDAD INTERIOR MODELO UNITÉ INTÉRIEURE OUTDOOR UNIT UNIDAD EXTERIOR UN...

Страница 4: ...t authorized service personnel Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands...

Страница 5: ...ration HORIZONTAL AIRFLOW COOLING DOWNWARD AIRFLOW HEATING For cooling use horizontal airflow so the cool air does not blow directly on the occupants in the room For heating use downward airflow to send powerful warm air to the floor and create a comfortable environment OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possi ble through dual use of bot...

Страница 6: ...Fan Speed Display b Temperature SET Display c AIR CLEAN Display d COIL DRY Display e SLEEP Display f SWING Display NAME OF PARTS Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time...

Страница 7: ...e direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 Y Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 Q to adjust the clock to the current time button Press to advance the time bu...

Страница 8: ...TROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperat...

Страница 9: ...ut 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defros...

Страница 10: ...he operation install the intake filter and then use the START STOP button to restart the operation Use the FAN CONTROL button to change the fan speed Refer to page 5 The plasma filter unit operates most effectively at the highest fan speed The AIR CLEAN Indicator Lamp orange will flash to inform you that the periodic cleaning of the plasma filter unit is required Refer to page 13 14 AIR CLEANING O...

Страница 11: ...econds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operat...

Страница 12: ...ps During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty minutes When the thermo stat has been raised a total of 4 F the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the ...

Страница 13: ...cally return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 T Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Co...

Страница 14: ...ot get rid of the existed mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using the following range according to the current airflow direc tion Airflow dir...

Страница 15: ...ille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and ...

Страница 16: ...4 to 113 F for 10 to 15 minutes If the plasma filter unit is extremely dirty extremely dilute a mild synthetic laun dry detergent low alkalinity or isotope detergent to 15 times the standard concentration and allow the plasma filter unit to soak in it 2 Gently move up and down and to the right and left A soft sponge can also be used to wipe the surface 3 Rinse with clean water 4 Shake the plasma f...

Страница 17: ...nts the two ends of its lower side as well as two center points of the lower side as shown in the figure to close it If after cleaning the dust collection unit the operation indicator lamp and the timer indicator lamp flash during Air Cleaning please ensure that the unit is not damp and that the intake grille is properly closed If after having checked that the unit is fully dry and that the intake...

Страница 18: ...aned once every six months Please only install filters that are licensed by our company Regarding storage and care of the filter please avoid exposing it to high temperatures and high humidity Also use it as soon as possible after opening its packaging Hook Filter case Filter Case Hook Hook Hook Click When removing the filter please follow these steps backwards How to install or remove the Air cle...

Страница 19: ...rted fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the thermostat for a higher setting During Heating operation the unit will temporarily stop opera tion between 7 and 15...

Страница 20: ...s If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Autom...

Страница 21: ... used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip o...

Отзывы: