En-4

PREPARATION

 

 CAUTION!

Take care to prevent infants from
accidentally swallowing batteries.

When not using the Remote Control Unit
for an extended period, remove the
batteries to avoid possible leakage and
damage to the unit.

If leaking battery fluid comes in contact
with your skin, eyes, or mouth, immedi-
ately wash with copious amounts of
water, and consult your physician.

Dead batteries should be removed
immediately and disposed of properly,
either in a battery collection receptacle
or to the appropriate authority.

Do not attempt to recharge dry batteries.

Never mix new and used batteries, or
batteries of different types.
Batteries should last about one year
under normal use. If the Remote Con-
trol Unit’s operating range becomes ap-
preciably reduced, replace the batteries
and press the RESET button with the tip
of a ballpoint pen or other small object.

Load Batteries (AAA/R03/LR03 

×

 2)

1

Press and slide the battery compartment lid on the re-
verse side to open it.

Slide in the direction of the arrow while pressing the 

 mark.

2

Insert batteries.

Be sure to align the battery polarities (

) correctly.

3

Close the battery compartment lid.

Set the Current time

1

Press the CLOCK ADJUST button (Fig. 6 

X

).

Use the tip of a ball-point pen or other small object to press the button.

2

Use the TIMER SET ( 

 / 

 ) buttons (Fig. 6 

P

) to

adjust the clock to the current time.

 button:

Press to advance the time.

 button:

Press to reverse the time.

(Each time the buttons are pressed, the time will be advanced/reversed in
one-minute increments; hold the buttons depressed to change the time
quickly in ten-minute increments.)

3

Press the CLOCK ADJUST button  (Fig. 6 

X

) again.

This completes the time setting and starts the clock.

To Use the Remote Control Unit

The Remote Control Unit must be pointed at signal receiver (Fig. 1 

4

) to operate

correctly.

Operating Range: About 7 meters.

When a signal is properly received by the air conditioner, a beeping sound will
be heard.

If no beep is heard, press the Remote Control Unit button again.

Remote Control Unit Holder

3

To remove the Remote
Control Unit (when use at
hand).

1

Mount the Holder.

2

Set the Remote Control
Unit.

Screws

Insert

Press in

Slide up

Pull out

Содержание Inverter Halcyon AOU24RL

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ... BTU h UISSANCE ABSORBÉE 2 31 kW NTENSITÉ 10 1 A UFFAGE UISSANCE FRIGORIFIQUE 27 600 BTU h UISSANCE ABSORBÉE 2 47 kW NTENSITE 10 8 A PECIFICATIONS ER SUPPLY 208 230 V 60 Hz LING APACITY 24 200 BTU h NPUT POWER 2 31 kW URRENT 10 1 A ING APACITY 27 600 BTU h NPUT POWER 2 47 kW URRENT 10 8 A EL INDOOR UNIT ÈLE UNIDAD INTERIOR ELO UNITÉ INTÉRIEURE OUTDOOR UNIT UNIDAD EXTERIOR UNITÉ EXTÉRIEURE ASU24RL ...

Страница 5: ...n the room For heating use downward airflow to send powerful warm air to the floor and create a comfortable environment OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possi ble through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the oper ating...

Страница 6: ...splay Fan Speed Display a Temperature SET Display b COIL DRY Display c SLEEP Display d SWING Display NAME OF PARTS Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installati...

Страница 7: ...e direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 X Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 P to adjust the clock to the current time button Press to advance the time bu...

Страница 8: ...TROL button Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperat...

Страница 9: ...ut 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defros...

Страница 10: ...econds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operat...

Страница 11: ...ps During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty minutes When the thermo stat has been raised a total of 4 F the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the ...

Страница 12: ...cally return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 S Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Co...

Страница 13: ...ot get rid of the existed mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using the following range according to the current airflow direc tion Airflow dir...

Страница 14: ...ille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and ...

Страница 15: ...disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the use...

Страница 16: ...condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor ...

Страница 17: ...s If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Autom...

Страница 18: ... used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip o...

Страница 19: ......

Отзывы: