En-8

TIMER OPERATION

To Use the ON timer or OFF timer

1

Press the START/STOP button (Fig. 6 b8)
(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a4) will light.

2

Press the TIMER MODE button (Fig. 6 b6) to select the
OFF timer or ON timer operation.

Each time the button is pressed the timer function changes in the follow-
ing order:

       CANCEL

OFF

ON

PROGRAM(OFF 

 ON, OFF 

 ON)

The indoor unit’s TIMER Indicator Lamp (orange)(Fig. 3 a5) will light.

3

Use the TIMER SET buttons (Fig. 6 b13) to adjust the
desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue
for about five seconds).

 button:

Press to advance the time.

 button:

Press to reverse the time.

About five seconds later, the entire display will reappear.

To Use the Program timer

1

Press the START/STOP button (Fig. 6 b8).
(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 a4) will light.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON timer or OFF timer” to set the desired
mode and times.
About three seconds later, the entire display will reappear.
The indoor unit’s TIMER Indicator Lamp (orange) (Fig. 3 a5) will light.

3

Press the TIMER MODE button (Fig. 6 b6) to select the
PROGRAM timer operation (OFF   ON or OFF 

 ON

will display).

The display will alternately show “OFF timer” and “ON timer”, then change
to show the time setting for the operation to occur first.

The program timer will begin operation. (If the ON timer has been se-
lected to operate first, the unit will stop operating at this point.)

About five seconds later, the entire display will reappear.

About the Program timer

The program timer allows you to integrate OFF timer and ON timer operations in
a single sequence. The sequence can involve one transition from OFF timer to
ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

The first timer function to operate will be the one set nearest to the current time.
The order of operation is indicated by the arrow in the Remote Control Unit’s
Display (OFF 

 ON, or OFF 

 ON).

One example of Program timer use might be to have the air conditioner auto-
matically stop (OFF timer) after you go to sleep, then start (ON timer) automati-
cally in the morning before you arise.

s

Before using the timer function, be sure that the Remote Control Unit is set to the correct current time (

 P. 5).

To Cancel the Timer

Use the TIMER MODE button to select
“CANCEL”.
The air conditioner will return to normal
operation.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the
timer setting wait until the entire display
reappears, then press the appropriate
buttons to change the operating condition
desired.

s

s

t

To Cancel the Timer

Use the TIMER MODE button to select
“CANCEL”.
The air conditioner will return to normal
operation.

To Change the Timer Settings

1. Follow the instructions given in the section

“To Use the ON Timer or OFF Timer” to se-
lect the timer setting you wish to change.

2. Press the TIMER MODE button to select

either OFF 

 ON or OFF 

 ON.

To Stop Air Conditioner Operation
while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions
(Mode, Fan Speed, Thermostat Setting,
SUPER QUIET mode), after making the timer
setting wait until the entire display reap-
pears, then press the appropriate buttons to
change the operating condition desired.

Содержание Inverter Halcyon AOU12RLS

Страница 1: ...Français MODE D EMPLOI MANUAL ASU9RLS ASU12RLS AOU9RLS AOU12RLS CONSERVEZ CE MODE D EMPLOI POUR RÉFÉRENCE ULTÉRIEUR 9314969034 ...

Страница 2: ...e replaced by the authorized service personal since special purpose tools and specified cord are required Provide occasional ventilation during use Do not direct airflow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air condi...

Страница 3: ...ir direction swing is possi ble through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the oper ating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy clean ing and maintenance MILDEW RESIS...

Страница 4: ...g 1 Fig 6 c7 c8 c9 c10 c2 c4 c5 c6 c3 c1 b1 b2 b4 b3 b5 b6 b13 b8 b9 b10 b11 b12 b7 b16 b15 b14 Fig 7 To facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current op eration ...

Страница 5: ... DRY Display c5 SLEEP Display c6 Transmit Indicator c7 Fan Speed Display c8 SWING Display c9 Timer Mode Display c10 Clock Display Fig 1 Indoor Unit a1 Operating Control Panel Fig 2 a2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized se...

Страница 6: ...ction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 b14 Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 b13 to adjust the clock to the current time button Press to advance the time butt...

Страница 7: ...tton Fig 6 b7 Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature ap...

Страница 8: ...r about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic D...

Страница 9: ...egrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Control Unit s Display OFF ON or OFF ON One example of Progra...

Страница 10: ...uring Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically...

Страница 11: ...oom with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 b9 Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow Direction Setting For better heating cooling effect it is recommended to s...

Страница 12: ...he COIL DRY button again during COIL DRY Operation COIL DRY Opera tion can be reset The COIL DRY Operation cannot get rid of the existed mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down...

Страница 13: ...rogress the following opera tions features cannot be used TIMER SLEEP FAN SPEED SWING How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 a2 on the main unit control panel To stop operation press the MANUAL AUTO button Fig 2 a2 once again Controls are located inside the Open Panel MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or o...

Страница 14: ...he panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Open Panel In the above figure the open panel is omitted for the expla nation Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of neutral detergent and warm water If you wash the filter be sure to allow it to dry thorough...

Страница 15: ...ackage The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy designed air cleaning filters UTR FC03 2 Sold separately to exchange the used dirty air cleaning filter Negative air ions deodorizing filter one sheet light blue The filter should be exchanged about every three years so as to maintai...

Страница 16: ...densation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor uni...

Страница 17: ...ps If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Auto...

Страница 18: ...for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 80 or more If the outdoor temperature is lower than the temperature scope in the list above in order to keep safe...

Страница 19: ......

Страница 20: ......

Отзывы: