FINISHING

(1) Insulate between pipes.

For rear, right, and bottom piping, overlap the connection pipe
heat  insulation  and  indoor  unit  pipe  heat  insulation  and  bind
them with vinyl tape so that there is no gap.

For left and left rear piping, butt the connection pipe heat insula-
tion and indoor unit pipe heat insulation together and bind them
with and vinyl tape so that there is no gap.

For left and left rear piping, wrap the area which accommodates
the rear piping housing section with cloth tape.

For left and left rear piping, bind the connection cord to the top
of the pipe with vinyl tape.

For left and left rear piping, bundle the piping and drain hose
together by wrapping them with cloth tape over the range within
which they fit into the rear piping housing section.

(2) Temporarily fasten the connection cord along the connection pipe

with vinyl tape. (Wrap to about 1/3 the width of the tape from the
bottom of the pipe so that water does not enter.)

(3) Fasten the connection pipe to the outside wall with a saddle, etc.
(4) Fill the gap between the outside wall pipe hole and the pipe with

sealer so that rain water and wind cannot blow in.

(5) Fasten the drain hose to the outside wall, etc.

Fig. 16

Pipe

(Saddle)

(Outside wall cap)

(Sealer putty)

(Outdoors)

Fig. 15

Connection pipe
(heat insulation)

Bind the pipes together
to that there is no gap.

Overlap the insulation

Indoor unit pipe
(heat insulation)

Vinyl tape

Pipe

Drain hose

Cloth tape

Wrap with cloth tape

Wall

Check the following:

View from indoors

Left piping

Connection cord

Pipe

Drain hose

GOOD

Lifted up

Saddle

Wave

End in water

BAD

Drain hose

BAD

BAD

For connection from the left rear

Connection cord

Drain hose

Wall pipe

Connection pipe

FRONT PANEL REMOVAL AND INSTALLATION

THE INTAKE GRILLE REMOVAL

(1) Open the intake grille.
(2) Pull down the knob.
(3) Lift the intake grille upward, until the axle at the top of the intake

grille is removed.

THE INTAKE GRILLE INSTALLATION

(1) The fixing axle of the intake grille is installed on the Panel.
(2) Lay down the intake grille.

THE FRONT PANEL REMOVAL

(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove four screws.
(3) The thumb is hung on the lower part as shown in the figure, and it

pulls to the front, pushing [-] mark , and bottom hooks (two posi-
tion) is removed from wall hook bracket.

(4) The front panel bottom is pulled to the front, and bottom hooks is

removed indoor unit.

(5) The  front  panel  is  pulled  to  the  front,  raising  the  upper  surface,

and a front panel is removed.

THE FRONT PANEL INSTALLATION

(1) Firstly, fit the lower part of the front panel, and insert top and bot-

tom hooks. (Three top sides, six bottom sides)

(2) Four screws is attached.
(3) The intake grille is attached.

Fig. 4

Top holes (two sides)

Top hole (center)

Top hook (center)

Front panel

Top hooks

(two sides)

Indoor unit

Wall hook bracket

Front panel

Push

[-] mark

Push

Front panel

Bearing

Mounting shaft

Intake grille

Intake grille

Knob

Front panel

Screws

(4 position)

Bottom hole

(six position)

Front panel

Indoor unit

Bottom hooks

(six position)

Содержание Inverter Halcyon AOU12R2

Страница 1: ... Connect all wiring tightly Loose wiring may cause overheating at con nection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or thin aluminum fins on the air conditioner can cut your fingers When Installing In a Ceiling or Wall Mak...

Страница 2: ...an air conditioner using R410A incurs pressure higher than when using R22 it is necessary to choose adequate materials Thicknesses of copper pipes used with R410A are as shown in Table1 Never use copper pipes thinner than 0 8mm even when it is available on the market Contents of change Pressure is high and cannot be measured with a conventional gauge To prevent erroneous mixing of other refrigeran...

Страница 3: ... and must be purchased separately CAUTION 9000 BTU h 12000 BTU h MINIMUM CIRCUIT AMPACITY 12 A 15 A MAXIMUM OVERCURRENT PROTECTION 15 A 20 A TIME DELAY FUSE OR HACR TYPE CIRCUIT BREAKER Cut each pipe to the appropriate length 12 30 cm to16 40 cm to dampen vibration between units B Foamed polyethylene insulation for copper pipes as required to precise length of piping Wall thickness of the insulati...

Страница 4: ... noise 5 Provide the space shown in Fig 2 so that the air flow is not blocked Also for efficient operation leave open three of the four direc tions front rear and both sides WARNING Install at a place that can withstand the weight of the indoor and outdoor units and install positively so that the units will not topple or fall CAUTION 1 Do not install where there is the danger of com bustible gas l...

Страница 5: ...e is not used the cord interconnecting the indoor and outdoor units may touch metal and cause electric leakage CAUTION Install the wall hook bracket horizontally and perpen dicularly Fig 2 Wall hook bracket Tapping screw Center notch String Rear piping Right piping Bottom piping Install the indoor unit piping in the direction of the wall hole and bind the drain hose and pipe together with vinyl ta...

Страница 6: ...ut Indoor unit pipe Connection pipe To prevent gas leakage coat the flare surface with refrigerator oil BENDING PIPES The pipes are shaped by your hands Be careful not to collapse them Do not bend the pipes in an angle more than 90 When pipes are repeatedly bent or stretched the material will harden making it difficult to bend or stretch them any more Do not bend or stretch the pipes more than thr...

Страница 7: ...ecurely 10 Fully open the valve stems of the 2 way valve and 3 way valve using a hexagon wrench After the valve stem begins to turn turn it with a torque of less than 2 17ft lbs 30 kgf cm until it stops turning 11 Firmly tighten the 2 way valve and 3 way valve blank cap and the charging port cap Fig 9 Tapping screw Rear hook Connector cover Always use the screws as shown above Do not select the to...

Страница 8: ...st Therefore be sure all wiring is tightly connected Connect wires to the matching numbers of terminals NOTE Connector trade size for this unit is 1 2 12 7 mm The connec tor can be bought at a hardware store Refer to How to connect wiring to the terminals for instructions on connecting depend ing on the wire type you are using The fuse located in the outdoor unit provides power supply pro tection ...

Страница 9: ...to the terminal Refer to the wiring diagram 3 Use the screws to install the cord clamp Connection cord Screw Cord clamp There is a terminal block inside Connection cord Screw Cord clamp A For solid core wiring or F cable 1 Cut the wire end with a wire cutter or wire cutting pliers then strip the insulation to about 15 16 25 mm to expose the solid wire 2 Using a screwdriver remove the terminal scre...

Страница 10: ...ape Pipe Drain hose Cloth tape Wrap with cloth tape Wall Check the following View from indoors Left piping Connection cord Pipe Drain hose GOOD Lifted up Saddle Wave End in water BAD Drain hose BAD BAD For connection from the left rear Connection cord Drain hose Wall pipe Connection pipe FRONT PANEL REMOVAL AND INSTALLATION THE INTAKE GRILLE REMOVAL 1 Open the intake grille 2 Pull down the knob 3 ...

Страница 11: ... button on the remote control unit while the air conditioner is running use a melallic object to short the two metal contacts under the battery compartment lid and send the TEST RUN sig nal from the remote control unit To end test operation press the remote control unit START STOP button When the air conditioner is run by pressing the test run button the OP ERATION indicator lamp and TIMER indicat...

Страница 12: ...er unit wire harness to the terminal correctly please refer to fig 20 to adjust the length of the part of Inter unit Wire har ness ahead from conduit holder 5 1 2 140mm 15 16 25mm 15 16 25mm 4 3 16 105mm 1 1 14AWG EARTH WIRE CONDUIT PLATE CONDUIT CONNECTOR Fig 20 ...

Страница 13: ...ting the cooling operation by the remote control unit Refer to TEST RUNNING The operation indicator lamp and timer indicator lamp will begin to flash simultaneously during test run 4 Close the valve stem of 3 way valve when the reading on the compound pressure gage becomes 0 05 0 Mpa 0 5 0 kg cm2 5 Stop the operation Press the START STOP button of the remote control unit to stop the operation CAUT...

Отзывы: