TIMER OPERATION

Before using the timer function, be sure that the Remote Controller is set to the correct current time (

 P. 5).

To Use the ON timer or OFF timer

1

  Press the START/STOP button (Fig. 5 

M

)

 

(if the indoor unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 

5

) will light.

2

  Press the TIMER MODE button (Fig. 5 

K

) to select the 

OFF timer or ON timer operation.

 

Each time the button is pressed the timer function changes in the following 
order:

 

       CANCEL  

OFF  

ON

 PROGRAM 

(OFF 

o

 ON, OFF 

m

 ON)

 

The indoor unit’s TIMER Indicator Lamp (orange) (Fig. 3 

6

) will light.

3

  Use the TIMER SET buttons (Fig. 5 

Q

) to set the de-

sired OFF time or ON time.

 

Set the time while the time display is  ashing (the  ashing will continue for 
about 5 seconds).

 button: 

Press to advance the time.

 button: 

Press to reverse the time.

 

About 5 seconds later, the entire display will reappear.

To Use the Program timer

1

  Press the START/STOP button (Fig. 5 

M

)

 

(if the indoor unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (green) (Fig. 3 

5

) will light.

2

  Set the desired times for OFF timer and ON timer.

 

See the section “To Use the ON timer or OFF timer” to set the desired mode 
and times.

 

About 3 seconds later, the entire display will reappear.

 

The indoor unit’s TIMER Indicator Lamp (orange) (Fig. 3 

6

) will light.

3

  Press the TIMER MODE button (Fig. 5 

K

) to select the 

PROGRAM timer operation (OFF   ON or OFF   ON

 

will display).

 

The display will alternately show “OFF timer” and “ON timer”, then change to 
show the time setting for the operation to occur  rst.

  The program timer will begin operation. (If the ON timer has been selected 

to operate  rst, the indoor unit will stop operating at this point.)

 

About 5 seconds later, the entire display will reappear.

About the Program timer

  The program timer allows you to integrate OFF timer and ON timer operations in a 

single sequence. The sequence can involve 1 transition from OFF timer to ON timer, 
or from ON timer to OFF timer, within a 24 hour period.

  The  rst timer function to operate will be the 1 set nearest to the current time. The 

order of operation is indicated by the arrow in the Remote Controller's Display 
(OFF  ON, or OFF  ON).

  One example of Program timer use might be to have the air conditioner automati-

cally stop (OFF timer) the operation after you go to sleep, then start (ON timer) the 
operation automatically in the morning before you arise.

To Cancel the Timer

Use the TIMER button to select “CANCEL”.
The indoor unit will return to normal operation.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation while 
the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions 
(Mode, Fan Speed, Thermostat Setting, 
SUPER QUIET mode), after making the timer 
setting and waiting until the entire display 
reappears, then press the appropriate buttons 
to change the operating condition desired.

To Cancel the Timer

Use the TIMER MODE button to select “CAN-
CEL”.
The air conditioner will return to normal opera-
tion.

To Change the Timer Settings

1.  Follow the instructions given in the section “To 

Use the ON Timer or OFF Timer” to select 
the timer setting you wish to change.

2.  Press the TIMER MODE button to select 

either OFF 

 ON or OFF 

 ON.

To Stop Air Conditioner Operation while 
the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions 
(Mode, Fan Speed, Thermostat Setting, SUPER 
QUIET mode), after making the timer setting 
and waiting until the entire display reappears, 
then press the appropriate buttons to change 
the operating condition desired.

9318657012_OM_EN.indd   9

7/31/2012   10:36:51 AM

Содержание Inverter 9318657012

Страница 1: ...MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this product ...

Страница 2: ... event of a malfunction burning smell etc immediately stop operation turn off the breaker and consult authorized service personnel In the event of refrigerant leakage be sure to keep away from re or any ammables consult an autho rized service personnel Provide occasional ventilation during use Do not direct air ow at replaces or heating apparatus Do not climb on or place objects on the air conditi...

Страница 3: ...eaner use and easier care Anti Bacterial Air Cleaning Filter The lter catches airborne fungi bacteria and smell The components in the lter suppress the growth of the fungi and bacteria that have been caught Remote controller WIRELESS REMOTE CONTROLLER The Wireless Remote Controller allows convenient control of indoor unit operation WIRED REMOTE CONTROLLER OPTION The optional wired remote controlle...

Страница 4: ...facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current operation Fig 6 Fig 2 Fig 3 Fig 4 ...

Страница 5: ...w Direction Louver C Right Left Louver behind Air ow Direction Louver D Drain Hose E Air Cleaning Filter F Remote Controller Wired Option Fig 5 Remote Controller G Signal Transmitter H MODE button I ECONOMY button J SLEEP button K TIMER MODE button L FAN button M START STOP button N SET button Vertical O SWING button P SET TEMP button Q TIMER SET button R CLOCK ADJUST button S TEST RUN button This...

Страница 6: ... arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 5 R Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 5 Q to adjust the clock to the current time button Press to advance the time button Press to reve...

Страница 7: ...idered a standard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN button Fig 5 L Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermostat setting the fan speed becomes ...

Страница 8: ...temperature setting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling Use to cool your room Dry Use for gently cooling while dehumidifying your room During Dry mode the indoor unit will operate at low speed in order to ad just room humidity the indoor unit s fan may stop from time to time Also the fan may ...

Страница 9: ...ater the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve 1 transition from OFF timer to ON timer or from ON timer to OFF timer within a 24 hour period The rst timer function to operate will be the 1 set nearest to the current time The order of operation is indicated by the...

Страница 10: ...e About 5 seconds later the entire display will reappear To Cancel the Timer Use the TIMER MODE button to select CAN CEL The air conditioner will return to normal opera tion To Stop the Air Conditioner During Timer Operation Press the START STOP button About the SLEEP Timer To prevent excessive cooling during sleep the SLEEP timer function automatically modi es the thermostat setting in accordance...

Страница 11: ...justments start air conditioner operation and be sure that the vertical air direction louvers are stopped DANGER Never place ngers or foreign objects inside the outlet ports since the internal fan operates at high speed and personal injury could be caused Always use the Remote Controller s SET button to adjust the vertical air ow louvers Attempting to move them manually could result in improper op...

Страница 12: ...g the ECONOMY operation button When ECONOMY operation mode is operated the room temperature will be little higher than the set temp under cooling mode Therefore the ECONOMY mode is able to save more energy than other normal mode SWING OPERATION Begin air conditioner operation before performing this procedure To select SWING Operation Press the SWING button Fig 5 O The SWING Display Fig 6 will ligh...

Страница 13: ...the unit is used under higher temperature conditions than those noted here the automatic protection circuit may operate interrupting the operation If the unit is used under lower temperature conditions than those noted here the heat exchanger may freeze causing water leakage or other malfunction Do not use the air conditioner for any purpose other than cooling or drying room or fan AUTO Restart In...

Страница 14: ...nd warm water If you wash the lter be sure to allow it to dry thoroughly in a shady place before reinstalling If dust is allowed to accumulate on the air lter air ow will be reduced lowering operating ef ciency and increasing noise During periods of normal use the Air Filters should be cleaned every two weeks Don t operate the air conditioner with being opened the intake grille When used for exten...

Страница 15: ...eaning effect please clean the lter in the follow way once six months 1 Remove the air cleaning lter 2 Clean with water and dry in the air 1 Flush the lter with fresh or warm water Please ush with diluted neutral detergent when extremely dirty Never wash by reaming or rubbing otherwise it will damage the deodorizing effect 2 Rinse with water ow 3 Dry in shade 3 Reinstall the air cleaning lter Air ...

Страница 16: ...rom the sudden Cooling of room air by the cool air emitted from the indoor unit resulting in con densation and misting Air ow is weak or stops During Dry mode the indoor unit will operate at low speed in or der to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity 8 During SUPER QUIET operation the fan will ...

Отзывы: