En-3

 NOTES

•  Attempting to move up/down air direction 

fl

 aps manu-

ally could result in improper operation; in this case, stop 
operation and restart. The louvers should begin to operate 
properly again.

•  When used in a room with infants, children, elderly or sick 

persons, the air direction and room temperature should be 
considered carefully when making settings.

Horizontal air direction adjustment

The function cannot be used.

 Swing operation

The type of operation

Range of swing

Cooling/Heating/Dry/Fan

1

 to 

4

The swing operation may stop temporarily when the air con-
ditioner’s fan is not operating, or when operating at very low 
speeds.

Hot start*

The indoor unit prevents cold drafts when Heating operation 
begins.
The indoor unit fan will not operate or it will operate at a very low 
speed until the heat exchanger reaches the set temperature. 

Low ambient cooling

When the outdoor temperature drops, the outdoor unit’s fans 
may switch to low speed, or one of the fans may stop inter-
mittently.

Mode operation

Auto

Cooling model:

•  When AUTO (auto changeover) operation 

fi

 rst selected, 

the fan will operate at very low speed for about a few 
minutes, during which time the indoor unit detects the 
room conditions and selects the proper mode.
Room temperature is higher than the de

fi

 ned temperature 

in temperature setting 

 Cooling mode

Room temperature is close to or lower than the de

fi

 ned 

temperature in temperature setting 

 Monitor operation

Cooling mode

Monitor operation

De

fi

 ned tem-

perature in 
temperature 
setting 

•  When the indoor unit has adjusted your room’s tempera-

ture to near the temperature setting, it will begin monitor 
operation. In the monitor operation mode, the fan will 
operate at low speed. If the room temperature subse-
quently changes, the indoor unit will once again select 
the appropriate operation (cooling) to adjust the tempera-
ture to the value set in the temperature setting.

•  If the mode automatically selected by the unit is not what 

you wish, select one of the mode operation (Cooling, 
Dry, Fan).

OPERATING TIPS

Instructions relating to heating (*) are applicable only to 
Heating and Cooling model (Reverse Cycle).

Heating performance*

•  This air conditioner operates on the heat-pump principle, 

absorbing heat from outdoor air and transferring that heat 
indoors. As a result, the operating performance is reduced 
as outdoor air temperature drops. Also, please consult with 
your installation technician to ensure the unit is correctly 
sized for the room space required.

•  Heat-pump air conditioners heat your entire room by recir-

culating air throughout the room, with the result that some 
time may be required after 

fi

 rst starting the air conditioner 

until the room is heated.

When indoor and outdoor temperatures are high*

When both indoor and outdoor temperatures are high during use 
of the Heating mode, the outdoor unit’s fan may stop at times.

Microcomputer-controlled automatic defrosting*

•  When using the Heating mode under conditions of low 

outdoor temperature and high humidity, frost may form on 
the outdoor unit, reducing the operating performance.
In order to prevent this reduced performance, this product 
is equipped with a microcomputer-controlled automatic 
defrosting function. During the defrost cycle, the indoor fan 
will shut down, and the defrost mode will be indicated. It 
will take maximum of 15 minutes before the air conditioner 
starts up again.

•  After Heating operation stops, if frost forms on the outdoor 

unit, the unit will start Automatic defrosting operation. 
At this time, the outdoor unit will automatically stop after 
operating for a few minutes.

Flow direction setting

Vertical air direction adjustment

Air

fl

 ow direction setting:

1

2

3

4

: During cooling/heat-

ing/dry mode

•  The vertical air

fl

 ow direction is set automatically as shown, 

in accordance with the type of operation selected.

During cooling/dry mode:  Horizontal 

fl

 ow 

2

During heating mode*: 

Downward 

fl

 ow  

4

(36 type or smaller capacity model)

3

(42 type or larger capacity model)

•  During AUTO mode operation, for the 

fi

 rst minute after 

beginning operation, air

fl

 ow will be horizontal 

2

; the air 

direction cannot be adjusted during this period.
Even if the 

fl

 ow direction is set, it may operate at a dif-

ferent position at the start of heating operation, during 
defrost, or when AUTO(auto changeover) is selected.

9381622061-02_OM_3L.indb   3

9381622061-02_OM_3L.indb   3

11/2/2018   11:31:08 AM

11/2/2018   11:31:08 AM

Содержание Halcyon AUU18RGLX

Страница 1: ...PARA FUTURA REFERENCIA OPERATING MANUAL Cassette type English MODE D EMPLOI Type cassette Français MANUAL DE FUNCIONAMIENTO Tipo casete Español PART No 9381622061 02 AUU18RGLX AUU24RGLX AUU30RGLX AUU36RGLX AUU42RGLX AUU48RGLX 9381622061 02_OM_3L indb i 9381622061 02_OM_3L indb i 11 2 2018 11 31 07 AM 11 2 2018 11 31 07 AM ...

Страница 2: ... Do not start or stop the operation of this product by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into the outlet port or inlet port Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate this product w...

Страница 3: ...he Operating manual of the remote controller NAME OF PARTS Indoor unit 2 1 2 2 2 3 2 4 1 3 1Air filter in air intake grille 2Airflow direction outlet Individual airflow direction control 1 2 3 4 3Air intake grille 4Remote controller For detailed instructions on how to operate please refer to the Operating manual of the remote controller CLEANING AND CARE CAUTION Before cleaning the unit be sure to...

Страница 4: ...and Cooling model Reverse Cycle Heating performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops Also please consult with your installation technician to ensure the unit is correctly sized for the room space required Heat pump air conditio...

Страница 5: ...erate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity The fan speed cannot be changed manually when Dry mode has been selected Fan Use to circulate the air throughout your room NOTES During Heating mode Set the thermostat to a temperature setting that is higher than the current ro...

Страница 6: ...ell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop...

Страница 7: ...or door open In the case of Cooling operation is a window allowing bright sunlight to enter Close the curtains In the case of Cooling operation are there heating ap paratus and computers inside the room or are there too many people in the room Is the unit set for Quiet operation Is the air conditioner in Economy mode If the problem persists after performing these checks or if you notice burning sm...

Страница 8: ...9381622061 02_OM_3L indb 7 9381622061 02_OM_3L indb 7 11 2 2018 11 31 10 AM 11 2 2018 11 31 10 AM ...

Отзывы: