background image

En-3

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

CAUTION

• To prevent malfunction or damage of the remote controller:

 

- Place remote controller at where will not be exposed to 

direct sunlight or excessive heat.

 

- Remove batteries if the product is not going to be used for 

an extended period.

 

- Exhausted batteries must be removed immediately, and 

be disposed according to the local laws and regulations of 
your region.

• If leaking battery 

fl

 uid comes in contact with your skin, eyes, 

or mouth, immediately rinse with plenty of clean water, and 
consult your physician.

• Obstacles such as a curtain or wall between the remote 

controller and the indoor unit may affect the appropriate 
signal transmission.

• Do not apply strong shocks to the remote controller.
• Do not pour water on the remote controller.
• Do not attempt to recharge dry batteries.

Remote controller holder installation

Slide up

Pull out

3

Insert

Press in

2

Screws

1

You can quickly start the operation with following 3 steps:

1 START/STOP 

button

2 MODE 

button

Switches operation mode in following order.

AUTO  

COOL  

DRY  

FAN  

HEAT

Notes in HEAT mode:

• At the beginning of the operation, the indoor unit operates at very 

low fan speed for about 3–5 minutes for preparation, and then 
switches to the selected fan speed.

• Automatic defrosting operation overrides the heating operation when 

it is necessary.

3  

SET TEMP. (temperature) buttons

Set desired temperature. 

Temperature setting range

AUTO

64–88 °F (18–30 °C)

COOL/DRY

64–88 °F (18–30 °C)

HEAT

60–88 °F (16–30 °C)

*:Temperature control is not available in FAN mode.

 

4 FAN 

button

Controls the fan speed.

AUTO  

HIGH  

MED  

LOW  

QUIET

• When AUTO is selected, the fan speed is automatically adjusted 

according to the operation mode.

5 SET 

button

Adjusts the vertical air

fl

 ow direction.

6 SWING 

button

Starts or stops automatic swing of the vertical air

fl

 ow direction louver.

• Each time you press the button, the vertical air

fl

 ow direction louver 

swings as follows:

1

2

3

7

6

5

4 4

COOL or DRY mode

HEAT mode

1

2

3

4

5

6 7

Note:

SWING operation may stop temporarily when the fan in the unit is 
rotating at very low speed or stopping.

Remote Controller Overview and Operations

5

6

15

12

11

13

14

2

3

16

4

10

7

1

9

8

7 RESET 

button

When you press the RESET button, press it gently by using the tip of 
a ballpoint pen or other small object in correct direction as shown in 
this 

fi

 gure.

RESET

8  TIMER CANCEL button

Cancels the set timer.

9  

ON TIMER button

Each time you press the button, the time changes as follows:

hours

0.5

1.0

1.5

2.0

...

9.0

9.5

10

11

12

• Set the time while the 

 indicator on the remote controller display 

is blinking.

10  OFF TIMER button

Each time you press the button, the time changes as follows:

hours

0.5

1.0

1.5

2.0

...

9.0

9.5

10

11

12

• Set the time while the 

 indicator on the remote controller display 

is blinking.

:  

The setting must be done within about 3 seconds during the indi-
cator stays solid.

 :  The button is controllable only when the air conditioner is on.

(continued)

9332621013_OM.indb   3

9332621013_OM.indb   3

9/21/2012   1:23:45 PM

9/21/2012   1:23:45 PM

Содержание Halcyon ASVG09LLCA

Страница 1: ...r plug or by turning on or off the circuit breaker Do not use inflammable gases near the unit Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAUTION Provide occasional ventilation during use Always operate the unit with air filters installed Ensure that ...

Страница 2: ...UTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal may not be transmitted properly In such a case consult the store that you purchased the product 7 ECONOMY in...

Страница 3: ...uttons Set desired temperature Temperature setting range AUTO 64 88 F 18 30 C COOL DRY 64 88 F 18 30 C HEAT 60 88 F 16 30 C Temperature control is not available in FAN mode 4 FAN button Controls the fan speed AUTO HIGH MED LOW QUIET When AUTO is selected the fan speed is automatically adjusted according to the operation mode 5 SET button Adjusts the vertical airflow direction 6 SWING button Starts...

Страница 4: ...tarts POWERFUL operation that enables quick cooling down or warming up of the room When you press the button to start the POWERFUL operation the indoor unit emits 3 short beeps POWERFUL operation is automatically turned off in the following situations Adjusted room temperature reached to the defined temperature in temperature setting in COOL DRY or HEAT mode 20 minutes have passed after finishing ...

Страница 5: ...he intake grille b b b a a 4 Press 4 places on the intake grille to close it completely Care and Cleaning Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the air...

Страница 6: ...operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 4 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUIET th...

Отзывы: