ELECTRIC CHARACTERISTICS
9.
Model name
AOU9RLS2H
AOU12RLS2H
AOU15RLS2H
Power supply
Voltage
V
208 / 230 ~
Frequency
Hz
60
MCA
A
14.5
18.2
Starting Current
A
3.7
5.5
6.1
*1) Wiring Spec.:
MAX. CKT. BKR
A
15
20
Power Cable
AWG
14
12
*2) Limited wiring length :
ft. (m)
60 (18)
75 (22)
*1) Wiring Spec.:
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E0005)
*2) Limited wiring length :
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.
MCA : Min Circuit Amp (Calculation based on UL1995)
MAX. CKT. BKR : Maximum Circuit Breaker