SAFETY DEVICES
10.
Protection form
Model
AOU9RLS2
AOU12RLS2
AOU15RLS2
Circuit protection
Current fuse
(NEAR THE TERMINAL)
20A 250V
25A 250V
5A 250V
Current fuse
(MAIN PRINTED CIRCUIT
BOARD)
15A 250V
10A 250V
3.15A 250V
3.15A 250V
Fan motor protection
Thermal protection
program
OFF : 212±18 °F (100±10 °C)
ON : 203±18 °F (95±10 °C)
Compressor protection
Thermal protection
program
(DISCHARGE TEMP.)
OFF : 230 °F (110 °C)
ON : After 7 minutes