background image

En-5

PREPARATION

 

 CAUTION!

 Take care to prevent infants from acciden-

tally swallowing batteries.

 When not using the Remote Controller for 

an extended period, remove the batteries to 
avoid possible leakage and damage to the 
unit.

 If leaking battery fluid comes in contact 

with your skin, eyes, or mouth, imme-
diately wash with copious amounts of 
water, and consult your physician.

 Dead batteries should be removed imme-

diately and disposed of properly, either in a 
battery collection receptacle or to the appro-
priate authority.

 Do not attem pt to recharge dry batteries.

Never mix new and used batteries, or 
batteries of different types.
Batteries should last about 1 year under 
normal use. If the Remote Controller’s 
operating range becomes appreciably 
reduced, replace the batteries and press 
the RESET button with the tip of a ball-
point pen or other small object.

Turn on the Power

1

  Turn on the circuit breaker.

Load Batteries (AAA/R03/LR03 

×

 2)

1

  Press and slide the battery compartment lid on the 

reverse side to open it.

 

Slide in the direction of the arrow while pressing the   mark.

2

 Insert 

batteries.

 

Be sure to align the battery polarities (

) correctly.

3

  Close the battery compartment lid.

Set the Current time

1

  Press the CLOCK ADJUST button.

 

Use the tip of a ball-point pen or other small object to press the button.

2

  Use the TIMER SET ( 

 / 

 ) buttons to adjust the 

clock to the current time.

 

   button: 

Press to advance the time.

 

   button: 

Press to reverse the time.

 

(Each time the buttons are pressed, the time will be advanced/reversed in 
1-minute increments; hold the buttons depressed to change the time quickly 
in 10-minute increments.)

3

  Press the CLOCK ADJUST button again.

 

This completes the time setting and starts the clock.

To Use the Remote Controller

  The Remote Controller must be pointed at signal receiver to operate correctly.

  Operating Range: About 7 meters.

 When a signal is properly received by the air conditioner, a beeping sound will be 

heard.

  If no beep is heard, press the Remote Controller button again.

Remote Controller Holder

3

  To remove the Remote 

Controller (when use at hand).

1

  Mount the Holder.

2

  Set the Remote Controller.

Screws

Insert

Press in

Slide up

Pull out

9374379446_OM.indb   5

9374379446_OM.indb   5

1/12/2553   14:51:04

1/12/2553   14:51:04

Содержание Floor/Ceiling Type

Страница 1: ...HEAT COOL MODEL REVERSE CYCLE AIR CONDITIONER Floor Ceiling Type OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE P N9374379446 ...

Страница 2: ...ith care When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precisio...

Страница 3: ...unction PROGRAM TIMER The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can in volve 1 transition from OFF timer to ON timer or from ON timer to OFF timer within a 24 hour period SLEEP TIMER When the SLEEP timer button is pressed during Heating mode the air conditioner s thermostat setting is gradually lowered during the pe riod of operat...

Страница 4: ... any chance press the START STOP button to stop the operation Please press the button at Filter Reset 3 Remote Controller Signal Receiver 4 OPERATION Indicator Lamp green 5 TIMER Indicator Lamp orange TIMER Indicator lamp lights when the timer is set from wireless remote control 6 ECONOMY Indicator Lamp green ECONOMY indicator lamp lights when ECONOMY OPERATION and 10 C HEAT OPERATION is operating...

Страница 5: ...ir conditioner s thermostat function to operate incorrectly If this button is pressed during normal opera tion the unit will switch to test operation mode and the Indoor Unit s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation mode press the START STOP button to stop the air conditioner F Signal Transmitter G Temperature SET Display H O...

Страница 6: ...id on the reverse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time button...

Страница 7: ... button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches t...

Страница 8: ...te at very low fan speed for about 3 to 5 minutes after which it will switch to the se lected fan setting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the outdoor temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle f...

Страница 9: ...st the desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION Indicator Lamp ...

Страница 10: ... hour 1 C 2 C 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automati cally raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is main tained until the set time has elapsed at which time the air condi tioner automatically turns off SLEEP timer...

Страница 11: ...h the AIR DIRECTION buttons on the Remote Controller Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow Direction Setting 1 2 3 4 During Cooling Dry...

Страница 12: ... not operating or when operating at very low speeds To select Up down swing operation ECONOMY OPERATION Begin Air Conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator Lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY Indicator Lamp green will go out No...

Страница 13: ...ble When two or more air conditioners are installed in a room please contact your retailer to set the individual air conditioner signal codes Selecting the Remote Controller Signal Code Indicator Lamp Lighting OFF If no buttons are pressed within 30 seconds after the signal code is displayed the system returns to the original clock dis play In this case start again from step 1 The air conditioner ...

Страница 14: ...lace before reinstalling If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increasing noise Filter Reset ECONOMY Indicator Lamp flashing The special setting Can be used if set correctly during installation Please consult authorized serviceman when using this function It lights on when it is time to clean the air filters After turning the ...

Страница 15: ... room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be se...

Страница 16: ...room by recir culating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high dur ing use of the heating mode the outdoor unit s fan may stop at times Microcomputer controlled Automatic Defrosting When using the Heating mo...

Страница 17: ...ated simultaneously but when 2 or more indoor units of the same group are operated simul taneously the heating and cooling efficiency will be less than when a single indoor unit is used alone Accordingly when you wish to use more than 1 indoor unit for cooling at the same time the use should be concentrated at night and other times when less output is required In the same way when multiple units a...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: