CLEANING AND CARE

Cleaning the Air Filter

1. Pull out both sides and the center of the 

intake grille.

About 30 mm

Side Panel

Intake Grille

Notch

Arm

Hook

Arm

2. Pull the air 

fi

 lters upward to remove them.

 

Push the air 

fi

 lter handles away from the intake grille in di-

rection [A], then pull out the air 

fi

 lters.

Handle

Intake Grille

Base

[A]

Air Filter

Bracket

3. Clean the air 

fi

 lters.

 

Remove the dust from the air 

fi

 lters by vacuuming or wash-

ing them. After washing, allow the air filters to dry thor-
oughly in an area protected from sunlight.

4. Re-attach the air 

fi

 lters to the intake grille.

(1) The air 

fi

 lters 

fi

 t onto the inside of the intake grille. (Figure 1)

(2) The bottom edges of the air 

fi

 lters should 

fi

 t into the 

fi

 lter 

brackets. (Figure 1)

(3) The  air 

fi

 lters should be pushed down so that their top 

edges 

fi

 t under the projections at the top of the intake 

grille. (Figure 2)

(Figure 1)

Filter bracket

Air Filter

(Figure 2)

5. Push in both sides and the center of the 

intake grille.

  Dust can be cleaned from the air 

fi

 lter either with a vacuum 

cleaner, or by washing the 

fi

 lter in a solution of mild deter-

gent and warm water. If you wash the 

fi

 lter, be sure to allow 

it to dry thoroughly in a shady place before reinstalling.

 If dirt is allowed to accumulate on the air 

fi

 lter,  air 

fl

 ow  will 

be reduced, lowering operating efficiency and increasing 
noise.

Filter Reset (ECONOMY Indicator Lamp 

fl

 ashing/ The special setting)

  

Can be used if set correctly during installation. 

Please consult authorized serviceman when using this function.

•  It lights on when it is time to clean the air 

fi

 lters.

After turning the power on, press the MANUAL AUTO button 
for 2 seconds or less on the indoor unit.

: Flashing

: OFF

  Before cleaning the air conditioner, be sure to turn it off and disconnect the power supply cable.

  Be sure the intake grille is installed securely.

 When removing and replacing the air 

fi

  lters, be sure not to touch the heat exchanger, as personal 

injury may result.

 CAUTION!

  When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the unit 

be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service personnel.

  When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like benzene or thinner.

  Do not expose the unit body to liquid insecticides or hairsprays.

● 

If the unit will not be operated for a period of 1 month or more, be sure to allow the inner parts of the unit to dry thoroughly, 
in advance, by operating the unit in fan mode for half a day.

9374379446_OM.indb   13

9374379446_OM.indb   13

1/12/2553   14:51:06

1/12/2553   14:51:06

Содержание Floor/Ceiling Type

Страница 1: ...HEAT COOL MODEL REVERSE CYCLE AIR CONDITIONER Floor Ceiling Type OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE P N9374379446 ...

Страница 2: ...ith care When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precisio...

Страница 3: ...unction PROGRAM TIMER The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can in volve 1 transition from OFF timer to ON timer or from ON timer to OFF timer within a 24 hour period SLEEP TIMER When the SLEEP timer button is pressed during Heating mode the air conditioner s thermostat setting is gradually lowered during the pe riod of operat...

Страница 4: ... any chance press the START STOP button to stop the operation Please press the button at Filter Reset 3 Remote Controller Signal Receiver 4 OPERATION Indicator Lamp green 5 TIMER Indicator Lamp orange TIMER Indicator lamp lights when the timer is set from wireless remote control 6 ECONOMY Indicator Lamp green ECONOMY indicator lamp lights when ECONOMY OPERATION and 10 C HEAT OPERATION is operating...

Страница 5: ...ir conditioner s thermostat function to operate incorrectly If this button is pressed during normal opera tion the unit will switch to test operation mode and the Indoor Unit s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation mode press the START STOP button to stop the air conditioner F Signal Transmitter G Temperature SET Display H O...

Страница 6: ...id on the reverse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time button...

Страница 7: ... button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches t...

Страница 8: ...te at very low fan speed for about 3 to 5 minutes after which it will switch to the se lected fan setting This period of time is provided to allow the indoor unit to warm up before beginning full operation When the outdoor temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle f...

Страница 9: ...st the desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION Indicator Lamp ...

Страница 10: ... hour 1 C 2 C 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automati cally raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is main tained until the set time has elapsed at which time the air condi tioner automatically turns off SLEEP timer...

Страница 11: ...h the AIR DIRECTION buttons on the Remote Controller Use the AIR DIRECTION buttons after the Indoor Unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 7 Types of Air flow Direction Setting 1 2 3 4 During Cooling Dry...

Страница 12: ... not operating or when operating at very low speeds To select Up down swing operation ECONOMY OPERATION Begin Air Conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator Lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY Indicator Lamp green will go out No...

Страница 13: ...ble When two or more air conditioners are installed in a room please contact your retailer to set the individual air conditioner signal codes Selecting the Remote Controller Signal Code Indicator Lamp Lighting OFF If no buttons are pressed within 30 seconds after the signal code is displayed the system returns to the original clock dis play In this case start again from step 1 The air conditioner ...

Страница 14: ...lace before reinstalling If dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increasing noise Filter Reset ECONOMY Indicator Lamp flashing The special setting Can be used if set correctly during installation Please consult authorized serviceman when using this function It lights on when it is time to clean the air filters After turning the ...

Страница 15: ... room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be se...

Страница 16: ...room by recir culating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated When Indoor and Outdoor Temperature are High When both indoor and outdoor temperatures are high dur ing use of the heating mode the outdoor unit s fan may stop at times Microcomputer controlled Automatic Defrosting When using the Heating mo...

Страница 17: ...ated simultaneously but when 2 or more indoor units of the same group are operated simul taneously the heating and cooling efficiency will be less than when a single indoor unit is used alone Accordingly when you wish to use more than 1 indoor unit for cooling at the same time the use should be concentrated at night and other times when less output is required In the same way when multiple units a...

Страница 18: ......

Страница 19: ......

Страница 20: ......

Отзывы: