Jumper setting
Description
1-2 (RST0)
DTR of UART0 used to
generate Reset
RST0 / RST1 (J9)
2-3 (RST1)
DTR of UART1 used to
generate Reset
1-2 (DTR)
No polarity inversion
for the DTR signal
DTR / /DTR (J10)
2-3 (/DTR)
Polarity inversion for
the DTR signal
Figure 9: J9, J10 jumper setting for Reset Generation (default: RST0/RST1= 1-2,
DTR/ /DTR = 1-2)
1.4.6 Configuration of the analog Interface
(J2, J3, J4)
The jumpers J2, J3 and J4 are used to configure the analog interface. J2 is used to
connect the analog ground AVss to the digital GND, J3 is used to connect the
analog power supply voltage AVcc to Vcc. Via jumper J4 the analog reference
voltage AVR can be selected.
Description
ON (closed)
AVss = GND(Analog
Ground = Digital
Ground)
J2 (AVss=GND)
OFF (open)
AVss disconnected
ON (closed)
AVcc=Vcc(Analog
Voltage Supply =
Digital Voltage supply
Vcc)
J3(AVcc =Vcc)
OFF (open)
AVcc not connected
ON(closed)
AVR=AVcc(Analog
Reference Voltage =
Analog Supply voltage
AVcc)
J4(AVR=AVcc)
OFF (open)
AVR defined by
Figure 10: J2, J3, J4 jumper setting for the analog Interface (J2(AVss)=ON,
J3(AVcc)=ON, J4(AVR=AVcc)=ON)