12
DIP Switch Settings
The factory default settings are as follows:
1 2 3 4 5 6 7 8
ON
OFF
(*Note: the
indicates the switch position)
DIP Switch Functions
SW No. Function
ON state / OFF state
1
Hot Key Mode:
<Ctrl>+<Alt>+<Shift> and
Hot-Key SW
ON: enabled / OFF: disabled
2
Hot Key Mode: Double <Ctrl>
ON: enabled / OFF: disabled
3
Hot Key Mode: Double <Scroll
Lock>
ON: enabled / OFF: disabled
4
Country Setting bit 1
(see following table)
5
Country Setting bit 2
(see following table)
6
Country Setting bit 3
(see following table)
7
Country Setting bit 4
(see following table)
8
Power Mode Setting
ON: the switch device is always ON.
OFF: the switch device turns ON if any
connected host is turned ON.
The country code (language) settings are as follows: For Sun Microsystems plat home only
Country Setting
SW4 SW5 SW6
SW7
JPN
ON ON ON ON
USA
ON ON ON OFF
GBR
ON ON OFF ON
GER
ON ON
OFF
OFF
FRA
ON OFF ON ON
ESP
ON OFF ON OFF
SWE
ON OFF OFF ON
POR ON
OFF
OFF
OFF
TPE
OFF ON ON ON
KOR
OFF ON ON OFF
ITA
OFF ON OFF ON
UNIX
OFF ON OFF OFF
NOR
OFF OFF ON ON
BEL
OFF OFF ON OFF
DEN
OFF OFF OFF ON