![Fujitsu eternus af Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/fujitsu/eternus-af/eternus-af_configuration-manual_121425037.webp)
Chapter 12
Non-disruptive Storage Migration
This chapter describes the procedures for connecting and disconnecting paths and provides notes for when
the Non-disruptive Storage Migration function is used in the example Native Multipath environment that
runs HP-UX 11iv3.
■
Connecting Paths
The following procedure shows how to add a path to the migration destination storage system from the serv-
er (HP-UX 11iv3) after the migration destination storage system is connected.
1
Check the multipath status.
Check the added LUNs.
[Thu Aug 03 19:48:30 rx28001:/] ioscan -kfnNC lunpath
Class I H/W Path Driver S/W State H/W Type Description
==================================================================
lunpath 0 0/0/0/1/0/0/0.0x0.0x0 eslpt CLAIMED LUN_PATH LUN path for ctl0
lunpath 1 0/0/0/1/0/0/0.0x0.0x1000000c0000000 eslpt CLAIMED LUN_PATH LUN path for disk4
lunpath 2 0/0/0/1/0/0/0.0x0.0x1010000c0000000 eslpt CLAIMED LUN_PATH LUN path for disk5
lunpath 3 0/0/0/1/0/0/0.0x0.0x1020000c0000000 eslpt CLAIMED LUN_PATH LUN path for disk6
lunpath 39 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x0 eslpt CLAIMED LUN_PATH LUN path for ctl7
lunpath 40 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4000000000000000 eslpt CLAIMED LUN_PATH LUN path for disk76
lunpath 41 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4001000000000000 eslpt CLAIMED LUN_PATH LUN path for disk77
lunpath 42 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4002000000000000 eslpt CLAIMED LUN_PATH LUN path for disk78
lunpath 43 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4003000000000000 eslpt CLAIMED LUN_PATH LUN path for disk79
lunpath 44 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4004000000000000 eslpt CLAIMED LUN_PATH LUN path for disk80
lunpath 46 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4005000000000000 eslpt CLAIMED LUN_PATH LUN path for disk81
lunpath 47 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4006000000000000 eslpt CLAIMED LUN_PATH LUN path for disk82
lunpath 48 0/0/0/7/0/0/0/5/0/0/0.0x2048000b5d6a0ba0.0x4007000000000000 eslpt CLAIMED LUN_PATH LUN path for disk83
lunpath 45 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x0 eslpt CLAIMED LUN_PATH LUN path for ctl7
lunpath 49 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4000000000000000 eslpt CLAIMED LUN_PATH LUN path for disk76
lunpath 50 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4001000000000000 eslpt CLAIMED LUN_PATH LUN path for disk77
lunpath 51 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4002000000000000 eslpt CLAIMED LUN_PATH LUN path for disk78
lunpath 52 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4003000000000000 eslpt CLAIMED LUN_PATH LUN path for disk79
lunpath 53 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4004000000000000 eslpt CLAIMED LUN_PATH LUN path for disk80
lunpath 54 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4005000000000000 eslpt CLAIMED LUN_PATH LUN path for disk81
lunpath 55 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4006000000000000 eslpt CLAIMED LUN_PATH LUN path for disk82
lunpath 56 0/0/0/8/0/0/0/5/0/0/0.0x2049000b5d6a0ba0.0x4007000000000000 eslpt CLAIMED LUN_PATH LUN path for disk83
lunpath 4 0/0/0/31/2.0x0.0x0 eslpt CLAIMED LUN_PATH LUN path for disk7
[Thu Aug 03 19:48:43 rx28001:/]
2
Connect the multipath.
Add the host affinity setting to the migration destination storage system.
3
Rescan the device.
[Thu Aug 03 20:00:51 rx28001:/] ioscan
37
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide -Server Connection- (Fibre Channel) for HP-UX
Copyright 2020 FUJITSU LIMITED
P3AM-3772-22ENZ0