background image

©

 c

o

g

n

it

as

. Ges

e

lls

c

h

ft

 f

ü

T

e

c

hni

k

-D

o

k

u

m

e

nt

at

ion m

b

H 20

11 

P

fa

d

C

:\

P

rogra

m

m

e

\F

C

T

\t

im

_a

pp

\t

im

_l

o

c

a

l\

w

or

k

\W

A

LT

E

R

\O

B

J

_

D

O

K

U

-5

6

9

3

-0

04

.f

m

Содержание D3030

Страница 1: ...Technical Manual English System Board D3030 for BX920 S2 Technical Manual Edition March 2011 ...

Страница 2: ...entation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 5694 004 fm Copyright 2011 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes ...

Страница 3: ...d in the mouse and keyboard are limited life components Use of these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly i...

Страница 4: ...otice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain su...

Страница 5: ...hnical Manual Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include CSS Customer Self Service Replacing the lithium battery ...

Страница 6: ...Technical Manual D3030 BX920 S2 cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 5694 004 fm ...

Страница 7: ...14 2 3 Environmental protection 15 3 Features 17 3 1 Overview 17 3 2 Main memory 21 3 2 1 Memory speed 28 3 3 Screen resolution 29 3 4 Temperature system monitoring 29 3 5 LED indicators 31 3 5 1 Internal indicators 31 3 5 2 External indicators 32 3 6 Interfaces connectors and DIP switch 33 3 7 Settings with switches and jumpers 34 4 Replacing the lithium battery 37 ...

Страница 8: ... cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 5689 004 fm ...

Страница 9: ...w Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server PRIMERGY Abbreviations and Glossary can also be found on the ServerView Suite DVD 2 1 1 Notational conventions The following notational conventions are used in this manual Text in italics indicates commands or menu items Quotation marks indicate names of chapters and terms that are being emphasized ...

Страница 10: ... cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 5690 004 fm ...

Страница 11: ...ff Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packagi...

Страница 12: ...has to comply with EN 50173 and EN 50174 1 2 standards or ISO IEC 11801 standard respectively The minimum requirement is a Category 5 shielded cable for 10 100 Ethernet or Category 5e for Gigabit Ethernet Never connect or disconnect data transmission lines during a storm risk of lightning hazard Batteries V CAUTION Incorrect replacement of batteries may lead to a risk of explosion The batteries ma...

Страница 13: ...ays discharge static build up e g by touching a grounded object before working with such components Any devices or tools that are used must be free of electrostatic charge Wear a suitable grounding cable that connects you to the external chassis of the system unit Always hold components with ESDs at the edges or at the points marked green touch points Do not touch any connectors or conduction path...

Страница 14: ...ards Take care not to tilt boards they must be installed perfectly straight If they are incorrectly handled the boards and the components on them or the other components e g EMI spring contacts and conductors can be damaged Handle all locking mechanisms engaging lugs and centering pins carefully when installing removing the board or components e g memory modules processors Never use sharp objects ...

Страница 15: ...rver fujitsu com primergy concept for the Japanese market Energy saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work Packaging information This packaging information doesn t apply to the Japanese market Do not throw away the packaging You may need it later for transporting t...

Страница 16: ...returns recycling and disposal in accordance with local regulations Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 525 1410 Fax 49 5251 525 32 1410 The device m...

Страница 17: ... and 16 GB Buffered and unbuffered DIMMs with ECC are supported mix of memory is not permitted Maximum 144 GB of memory Minimum 2 GB 1 memory module Maximum 32 Gbit s band width DDR3 CPU0 has 2 DIMM slots for memory rows per channel CPU1 has 1 DIMM slot for memory row per channel ECC multiple bit error detection and single bit error correction Memory scrubbing functionality Single Device Data Corr...

Страница 18: ...e front side 1x serial interface at the front side 1x VGA Internal connectors 1x video connector VGA at the front side 1x universal USB port for 4 USB connectors at the front side 1x UFM connector USB Flash Module connection for USB Flash ROM 9x slots for DDR3 memory modules Power supply 12 V and 5 V auxiliary supply iRMC S2 server management controller Basic features Temperature monitoring System...

Страница 19: ...al ports LAN PCIe controller and iRMC S2 Switch on the server via the power switch external serial ports LAN PCIe controller and iRMC S2 BIOS features AMI SMBIOS 2 5 DMI MultiProcessor specification Server Hardware Design Guide WfM ACPI support LSI SAS RAID BIOS USB keyboard mouse boot possible from hard disk SATA SAS SCSI USB USB stick CD DVD SATA SAS LAN console redirection support OEM logo CPU ...

Страница 20: ... memory for software e g VMware or as a software dongle Trusted Platform Module TPM A Trusted Platform Module TPM for safer storage of keys can be implemented as an option This module enables programs from third party manufacturers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the BIOS m...

Страница 21: ...memory modules in the Options Guide of your server blade Configuration of the main memory Figure 2 Main memory configuration The memory modules are organized in 3 channels per CPU CPU1 has 3 channels with 2 slots each 0 and 1 and CPU2 has 3 channels with 1 slot each The channels A C are controlled by CPU 1 and the channels D F are controlled by CPU 2 x4 or x8 organized registered RDIMMs or unbuffe...

Страница 22: ...he channels B and E contain the mirrored data of the memory belonging to channel A and D The channels C and F are not used Performance channel mode maximum performance The populated memory of the six channels A F can be used completely max 144 GB Spare channel mode large population and large security Only the populated memory of the four channels A B D and E can be used max 96 GB The channels C an...

Страница 23: ...l timings except for the clock frequency can vary between the channels Always start by populating the main memory at CPU 1 If CPU 2 is installed the following applies For CPU 2 there must be at least one DIMM module DIMM 1D installed The DIMM slots must be fitted in the following sequence CPU 2 CPU 1 DIMM 1F DIMM 1D DIMM 1E DIMM 2A DIMM 2B DIMM 2C DIMM 1B DIMM 1C DIMM 1A CPU 2 CPU 1 DIMM 1F DIMM 1...

Страница 24: ...s to ensure sufficient cooling of the system this does not apply if two CPUs are installed If memory modules with different memory capacities are to be installed for a CPU then the rule applies that the higher the capacity the further away from the CPU the memory module has to be mounted per channel The DIMM sockets must be populated per channel in the following order Channel 0 CPU 1 DIMM1A DIMM1B...

Страница 25: ...ng Memory modules with different clock frequencies and different speed ratings can be used within a channel whereby the settings of the slowest memory module are used for the channel In Mirrored Channel Mode the total main memory available in the system is half as large as the installed memory Figure 4 Fitting in Mirrored Channel Mode CPU 1 CPU 2 DIMM 2A DIMM 1A DIMM 2B DIMM 1F empty empty empty 1...

Страница 26: ...ck frequencies and different speed ratings can be used within a channel whereby the settings of the slowest memory module are used for this channel Figure 5 Fitting in Performance Channel Mode V CAUTION If only CPU 1 is installed the empty DIMM slots of CPU 1 must be fitted with dummy DIMM modules to ensure sufficient cooling of the system this does not apply if two CPUs are installed CPU 1 CPU 2 ...

Страница 27: ...dules with different clock frequencies and different speed ratings can be used within a channel whereby the settings of the slowest memory module are used for the channel The timings in the active channels A and B and in the spare channel C can be set differently Only 2 3 of the maximum memory bandwidth is available in Spare Channel Mode In Spare Channel Mode the total main memory available in the...

Страница 28: ...max 1066 MHz for 1 35 V memory The memory channel with the lowest speed defines the speed of all CPU channels in the system DIMM type DIMM slots per channel DIMMs populated per channel Max memory speed CPU dependent Ranks per DIMM 2 2 1 800 1066 1333 SR DR RDIMM 2 2 1 800 1066 QR 1 5 V 2 2 2 800 1066 1333 Mix of SR DR 1333 MHz 2 2 2 800 Mix of QR SR DR 2 2 1 800 1066 1333 SR DR RDIMM 2 2 1 800 106...

Страница 29: ...is provided about the system status The temperature and system monitoring are controlled by the iRMC S2 integrated Remote Management Controller The following functions are supported Temperature monitoring Measurement of the processor and the system internal temperature by an onboard temperature sensor measurement of the ambient temperature by a I2C temperature sensor Fan control The fans are regul...

Страница 30: ...l high or falls below warning level low an alert will be generated System Event Log SEL All monitored events of the system board are signalized via the Global Error LED and recorded in the System Event Log The events could be retrieved in the BIOS Setup in the Management Blade Web interface via the iRMC S2 s Web interface or via ServerView Operations Manager Diagnostic LEDs For signalisation of fa...

Страница 31: ...wing figure the defective component can also be displayed in the power off state power plug disconnected Figure 7 LEDs LED Indicator Meaning 1 Mezzanine card 1 yellow Error on Mezzanine card 1 2 DIMMs 1D 1F yellow Faulty memory module 3 CPU 1 yellow CPU faulty 4 DIMMs 1A 1C 2A 2C yellow Faulty memory module 5 CSS button none Activates the LEDs in case of an error 6 CPU 2 yellow CPU faulty 7 Mezzan...

Страница 32: ...OBJ_DOKU 5692 004 fm 3 5 2 External indicators Figure 8 External ports of the system board D3030 Pos Name LED lighting Pos Name LED lighting 1 Power on Power off green orange 5 Connection LED Fabric 1 green 2 Identification LED blue 6 Connection LED Fabric 2 green 3 Global Error LED orange 7 Connection LED Fabric 3 and 4 green 4 CSS LED yellow 1 2 3 4 5 6 7 ...

Страница 33: ...xternal ports of the system board D3030 1 Slot 1 for Mezzanine card 1 7 Memory slots1A 1C 2A 2C 2 Memory slots 1D 1F 8 Slot 2 for Mezzanine card 2 3 DIP switch 9 Mezzanine card 2 4 Slot for hard disk 1 10 Mezzanine card 1 5 Slot for hard disk 2 11 TPM 6 UFM 12 Battery 1 4 way connector USB VGA serial Y cable CPU 1 CPU 2 HDD 2 HDD 1 Mezzanine Card 1 Mezzanine Card 2 1 2 3 4 5 6 8 7 9 10 11 12 1 ...

Страница 34: ...er the BIOS default settings are to be loaded or not Switch 2 Clear Password Switch 2 specifies whether the BIOS password should be requested at system boot if password protection is activated in the BIOS setup the Password on boot field is set to enabled in the SECURITY menu on The BIOS default settings are loaded the user defined settings are deleted off The user defined settings are retained de...

Страница 35: ... the system BIOS you need a BIOS flashing medium for more information refer to the BIOS manual or contact the customer service team Switch 4 No function This switch currently has no function on The system starts from the BIOS flashing medium ODD USB stick and reprograms the system BIOS on the board off The system starts with the system BIOS of the system board default setting ...

Страница 36: ...36 Technical Manual D3030 BX920 S2 Settings with switches and jumpers cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 5692 004 fm ...

Страница 37: ...ced with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trash can Batteries must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 12 Replacing the lithium battery Ê Press the locking spring into directio...

Страница 38: ... cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 5693 004 fm ...

Отзывы: