Technical Manual - English

System Board D2861
for BX922 S2   

Technical Manual

Edition March 2011

Содержание D2861

Страница 1: ...Technical Manual English System Board D2861 for BX922 S2 Technical Manual Edition March 2011 ...

Страница 2: ...entation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 9414 003 fm Copyright 2011 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes ...

Страница 3: ...hese components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The custo...

Страница 4: ...otice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain su...

Страница 5: ...ual Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include USB Flash Module UFM CSS Customer Self Service Replacing the lithium battery ...

Страница 6: ...Technical Manual D2861 BX922 S2 cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 9414 003 fm ...

Страница 7: ... 15 3 Performance features 17 3 1 Overview 17 3 2 Main memory 22 3 2 1 Memory speed 29 3 3 Supported screen resolutions 30 3 4 Temperature and system monitoring 30 3 5 LED indicators 32 3 5 1 Internal LEDs 32 3 5 2 External LEDs 33 3 6 Ports switch and plugged connectors 34 3 7 Settings with switches and jumpers 36 4 Replacing the lithium battery 39 ...

Страница 8: ...Technical Manual D2861 BX922 S2 Contents cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 9415 003 fm ...

Страница 9: ...n PDF format on the ServerView Suite DVD 2 The ServerView Suite DVD 2 is part of the ServerView Suite supplied with every server PRIMERGY Abbreviations and Glossary can also be found on the ServerView Suite DVD 2 Notational conventions The meanings of the symbols and fonts used in this manual are as follows Italics Indicates commands menu options or software programs Quotation marks Indicate names...

Страница 10: ...10 Technical Manual D2861 BX922 S2 Preface cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 9416 003 fm ...

Страница 11: ...ust be performed by qualified staff Failure to comply with the guidelines in this manual or any attempt at repair by untrained personnel can endanger the user electric shock fire hazard and or may cause material damage to the board or device such actions will also void the warranty and exempt the manufacturer from all liability Only transport the board in the original antistatic packaging or in pa...

Страница 12: ... 50174 1 2 apply for LAN cabling The minimum requirement is the use of a category 5 shielded LAN cable for 10 100 Mbit s Ethernet or a category 5e cable for Gigabit Ethernet The requirements of the specification ISO IEC 11801 must also be taken into account Do not connect or disconnect any data transmission cables during a thunderstorm lightning hazard Batteries V CAUTION If the lithium battery is...

Страница 13: ...g by touching a grounded object before working with the components The equipment and tools you use must be free of static charge Remove the device power plug before inserting or removing boards Always hold boards by their edges Do not touch any connector pins or conductors on the component When installing or removing components on the board use a suitable grounding cable Place all components on a ...

Страница 14: ... not to tilt boards they must be installed perfectly straight If they are incorrectly handled the boards and the components on them or the other components e g EMI spring contacts and conductors can be damaged Handle all locking mechanisms engaging lugs and centering pins carefully when installing removing the board or components e g memory modules processors Never use sharp objects screwdrivers a...

Страница 15: ...y saving information Devices that do not need to be constantly switched on should be switched off until they are needed as well as during long breaks and after completion of work I The On Off button does not disconnect the device from the mains To disconnect from the mains completely remove the power plug s Packaging information This packaging information does not apply to the Japanese market Do n...

Страница 16: ...recycling and disposal Details regarding the return and recycling of devices and consumables within Europe can also be found in the Returning used devices manual via your local Fujitsu Technology Solutions branch or from our recycling center in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 PaderbornGermany Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device must not be disposed of...

Страница 17: ...GB 4 GB 8 GB and 16 GB Both unbuffered UDIMM up to 2 GB and buffered RDIMM up to 16 GB memory modules are supported mix of memory is not permitted Maximum 192 GB memory minimum 2 GB 1 memory module Maximum 32 Gbit s bandwidth DDR3 Both CPUs have 2 DIMM slots for memory per channel ECC error detection and error correction Memory Scrubbing function Single Device Data Correction SDDC function Chipkil...

Страница 18: ... ports at the front 1x serial port on the front 1x VGA internal connectors 1x VGA port on the front 1x USB port for 4 USB ports on the front 1x UFM port USB Flash Module port for USB Flash ROM 12x ports for DDR3 memory modules Power supply 12V and 5V auxiliary voltage iRMC S2 server management controller Basic features Temperature monitoring System Event Log and ASR R Automatic Server Reconfigurat...

Страница 19: ... standby via RTC external serial ports LAN PCIe controller and iRMC S2 Switch on the server via the power switch external serial ports LAN PCIe controller and iRMC S2 BIOS features AMI SMBIOS 2 5 DMI MultiProcessor Specification Server Hardware Design Guide WfM ACPI support LSI SAS RAID BIOS USB keyboard mouse Boot capabilities from Hard disk SSD SATA SAS SCSI USB USB stick CD DVD USB LAN Console ...

Страница 20: ...and PCI Express Card Electromechanical Specification Rev 1 0 USB2 0 SATAII 2 0 CSS Customer Self Service I This feature is not available for the japanese market This system board supports the CSS functionality You can find a description of this in the operating manual for your server UFM optional I This feature is not available for the japanese market By the manufacturer the system board is equipp...

Страница 21: ...ia the BIOS system for more information refer to the BIOS manual V CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a backup of the TPM content To do this follow the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data If a failure occurs p...

Страница 22: ... a description on how to install remove the memory modules in the Options Guide for your server Configuration of the main memory Figure 2 Configuring the main memory in channels and slots The memory modules are organized in 3 channels with 2 slots each per CPU Channels A C are controlled by CPU 1 and channels D F are controlled by CPU 2 x4 or x8 organized registered RDIMMs or unbuffered UDIMMs mem...

Страница 23: ...ormance Channel Mode maximum performance The populated memory in the 6 channels A F can be used in full max 192 GB Spare Channel Mode high memory configuration with high security I This mode is only supported by Intel processors of type Intel Xeon processors of the 5600 series Only the populated memory in the 4 channels A B D and E can be used max 128 GB Channels C and F are for failure protection...

Страница 24: ...2 is installed the following applies For CPU 2 there must be at least one DIMM module DIMM 1D installed The DIMM slots must be fitted in the following sequence CPU 1 CPU 2 DIMM 1C DIMM 1B DIMM 1A DIMM 2B DIMM 2A DIMM 2C DIMM 2D DIMM 2E DIMM 2F DIMM 1E DIMM 1F DIMM 1D OEFQFOEFOU IBOOFM PEF CPU 2 CPU 1 DIMM 1C DIMM 1B DIMM 1A DIMM 2B DIMM 2A DIMM 2C DIMM 2D DIMM 2E DIMM 2F DIMM 1E DIMM 1F DIMM 1D JS...

Страница 25: ...re to be installed for a CPU the modules with the lower memory capacity must be installed first see also the following figure Small memory modules Large memory modules DIMM 1A DIMM 1D DIMM 1B DIMM 1E DIMM 1C DIMM 1F DIMM 2A DIMM 2D DIMM 2B DIMM 2E DIMM 2C DIMM 2F CPU 2 CPU 1 Channel 0 Channel 2 Channel 1 Slot 0 Slot 1 Slot 0 Slot 1 Slot 0 Slot 1 DIMM 1C 5 DIMM 2C 11 DIMM 1B 3 DIMM 2B 9 DIMM 1A 1 D...

Страница 26: ...cally However the corresponding slots in channels 0 and 1 must be equipped identically Memory modules with different clock frequencies and different speed ratings can be used within a channel whereby the settings of the slowest memory module are used for the channel In Mirrored Channel Mode the total main memory available in the system is half as large as the installed memory Figure 5 Fitting in M...

Страница 27: ...tings can be used within a channel whereby the settings of the slowest memory module are used for this channel In this mode symmetrical fitting of the slots of both CPUs is not required Figure 6 Fitting in Performance Channel Mode V CAUTION If only one CPU is installed the empty DIMM slots must be fitted with dummy DIMM modules to ensure sufficient cooling of the system this does not apply if two ...

Страница 28: ...identically but the corresponding slots of all three channels must be populated identically Memory modules with different clock frequencies and different speed ratings can be used within a channel whereby the settings of the slowest memory module are used for the channel The timings in the active channels A and B and in the spare channel C can be set differently Only 2 3 of the maximum memory band...

Страница 29: ...e lowest speed defines the speed of all CPU channels in the system DIMM type DIMM slots per channel DIMMs populated per channel Max memory speed CPU dependent Ranks per DIMM 2 2 1 800 1066 1333 SR DR RDIMM 2 2 1 800 1066 QR 1 5 V 2 2 2 800 1066 1333 Mix of SR DR 1333 MHz 2 2 2 800 Mix of QR SR DR 2 2 1 800 1066 1333 SR DR RDIMM 2 2 1 800 1066 QR LV 1 35 V 2 2 2 800 1066 Mix of SR DR 1333 MHz 2 2 2...

Страница 30: ...ature and system monitoring is to reliably protect the computer hardware from damage in the event of overheating It is also designed to prevent unnecessary noise generation by reducing the fan speed and to provide information about the status of the system The temperature and system monitoring are controlled by the iRMC S2 integrated Remote Management Controller The following functions are support...

Страница 31: ...wer monitoring If the voltage exceeds or falls below the specified limit values an alarm is generated System Event Log SEL All monitored events on the system board are signaled by the status indicator Global Error and recorded in the System Event Log You can check these in the BIOS setup or using ServerView The events could be retrieved in the BIOS Setup in the Management Blade Web interface via t...

Страница 32: ... figure the defective component can also be displayed in the power off state power plug disconnected Figure 8 LEDs on the D2861 system board Pos Name LED lighting Meaning 1 Mezzanine board 1 yellow Error on mezzanine board 1 2 CSS button none activates the LEDs in case of an error 3 DIMMs 1A 1C 2A 2C yellow Memory module defective 4 CPU 2 yellow CPU defective 5 DIMMs 1D 1F 2D 2F yellow Memory modu...

Страница 33: ...ternal ports of the D2861 system board Pos Name LED lighting Pos Name LED lighting 1 Power on Power off green orange 5 Connection LED Fabric 1 green 2 Identification LED blue 6 Connection LED Fabric 2 green 3 Global Error LED orange 7 Connection LED Fabric 3 and 4 green 4 CSS LED yellow 1 2 3 4 5 6 7 8 ...

Страница 34: ...tic diagram of the D2861 system board 1 Battery 6 UFM 2 TPM 7 Data connectors for SSD 0 or SATA HDD 0 bottom and SSD 1 or SATA HDD 1 top 3 Slot for mezzanine board 1 8 Power connectors for SSD 0 or SATA HDD 0 bottom and SSD 1 or SATA HDD 1 top 4 Memory slots 1A 1C and 2A 2C 9 Memory slots 1D 1F and 2D 2F 5 DIP switch 10 Slot for mezzanine board 2 CPU 2 CPU 1 DIMM 2D DIMM 1D DIMM 2E DIMM 1E DIMM 1F...

Страница 35: ...D2861 BX922 S2 Technical Manual 35 Performance features Ports switch and plugged connectors External ports Figure 11 External ports of the D2861 system board 1 4 way port USB VGA serial Y cable 1 ...

Страница 36: ...ecifies whether the BIOS default settings are to be loaded or not Switch 2 Clear Password Switch 2 specifies whether the BIOS password should be requested at system boot if password protection is activated in the BIOS setup the Password on boot field is set to enabled in the SECURITY menu on The BIOS default settings are loaded the user defined settings are deleted off The user defined settings ar...

Страница 37: ...o restore the system BIOS you need a BIOS flashing medium for more infor mation refer to the BIOS manual or contact the customer service team Switch 4 TBS Override This switch currently has no function on The system starts from the BIOS flashing medium ODD USB stick and reprograms the system BIOS on the board off The system starts with the system BIOS of the system board default setting ...

Страница 38: ...ical Manual D2861 BX922 S2 Settings with switches and jumpers Performance features cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 9419 003 fm ...

Страница 39: ...rer This information does not apply to the Japanese market Do not throw lithium batteries into the trash can Batteries must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 13 Replacing the lithium battery Ê Press the locking spring into direction of the arrow 1 so that the...

Страница 40: ...40 Technical Manual D2861 BX922 S2 Replacing the lithium battery cognitas Gesellschft für Technik Dokumentation mbH 2011 Pfad C Programme FCT tim_app tim_local work WALTER OBJ_DOKU 9420 003 fm ...