34

Technical Manual

 

D2619 (RX/TX300 S5)

Settings with switches and jumpers

Features

Write protection for Flash BIOS - switch 3

Switch 3 is used to define whether the System BIOS is write protected or not. 

Switch 4

not used

TPM jumper

Figure 13: Position of the TPM jumper (TPM enable)

I

As default the jumper (1-2) is set. Without jumper the TPM function is 
disabled.

on

The System BIOS can not be written. Flash-BIOS update from floppy 
disk is not possible.

off

The System BIOS can be written. Flash-BIOS update from floppy disk is 
possible (default setting).

Pin

Signal

Description

1

TPM RESET L

Reset of the TPM module

2

ICH TMP DIS L

Reset of ICH10

TP

enable

TP

M C

ON

Содержание D2619

Страница 1: ...System Board D2619 for RX TX300 S5 Technical Manual Edition April 2009 ...

Страница 2: ...nsistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2009 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to ava...

Страница 3: ...tificate 10 2 3 Environmental Protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 18 3 3 PCI bus 24 3 4 Screen resolution 25 3 5 Temperature system monitoring 25 3 6 LEDs 27 3 7 Interfaces and connectors 29 3 7 1 External ports 31 3 8 Settings with switches and jumpers 33 4 Replacing the lithium battery 35 ...

Страница 4: ......

Страница 5: ...font indicate system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols...

Страница 6: ......

Страница 7: ... Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging...

Страница 8: ...As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBit s Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosi...

Страница 9: ...touching a grounded object before working The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you ins...

Страница 10: ...eat care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp objects screwdrivers for leverage 2 2 CE ...

Страница 11: ... used and should be switched off during long breaks and on completion of work I The ON OFF switch does not separate the server from the line voltage For the complete separation from the line voltage you must pull the power supply plugs Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting ...

Страница 12: ...sidiary or our recycling centre in Paderborn Fujitsu Technology Solutions Recycling Center D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline dete...

Страница 13: ...ed RDIMM memory modules with 2 GB 4 GB and 8 GB maximum 144 GB of memory minimum 2 GB 1 memory module maximum 32 Gbit s band width DDR3 up to 3 dual or 2 quad memory rows per channel ECC multiple bit error detection and single bit error correction memory scrubbing functionality Single Device Data Correction SDDC function Chipkill Mirroring Sparing Chips on the system board Intel 5520 chipset Intel...

Страница 14: ...A2 3 Gbit s 2x USB 2 0 internal USB backup drives and USB FDD 1x internal USB2 0 memory stick External connectors 2x serial interfaces COM 4x USB 2 0 interfaces with 480 Mbit s at the rear side 1x VGA 2x RJ45 LAN 1x RJ45 service LAN Internal connectors 2x serial ATA 1x operating panel 1x VGA port at the front side 1x universal USB port 1x USB port for 3 USB ports at the front side 2x USB ports for...

Страница 15: ...guration and Restart PDA Global Error CSS ID LED HD LED support SAS IDE SATA SCSI Inventory Identification Control pre failure warranty for memory CSS functionality power consumption control text console redirection Advanced Video Redirection AVR remote storage Security features system and BIOS password recovery BIOS support flash write protection against virus Power management ACPI states S0 S1 S...

Страница 16: ...ng Form factor slot compatibility list 415 x 417mm ACPI 2 0 OnNow PCI Express 2 0 LPC 1 1 WfM 2 0 SHDG 3 0 MPS 1 4 IPMI 1 5 PCI SHPC 1 0 and PCI Express card electromechanical specifi cation rev 1 0 USB2 0 SATAII 2 0 CSS Customer Self Service This system board supports the CSS functionality You will find a description of CSS functionality in the operating manual of your server uSSD Solid State Dis...

Страница 17: ...turers to store key information e g drive encryption using Windows Bitlocker Drive Encryption The TPM is activated via the BIOS system for more information refer to the BIOS manual V CAUTION When using the TPM note the program descriptions provided by the third party manufacturers You must also create a backup of the TPM content To do this follow the third party manufacturer s instructions Without...

Страница 18: ...install memory modules in the Options Guide of your server Module population Figure 2 Assembly of the main memory in channels and slots The arrows in figure 2 show the direction of the population of the memory slots The memory modules are organized in 6 channels A F Each channel has three slots 1 3 The channels A C are controlled by CPU 1 and the channels D F are controlled by CPU 2 Only x4 organi...

Страница 19: ... D can be used max 48 GB The channels B and E serve as safeguarding against failure The memory belonging to the channels B and E contain the mirrored data of the memory belonging to channel A und D The channels C und F are not used Spare channel mode large population and large security Only the populated memory of the four channels A B D and E can be used max 96 GB The channels C and F serve as sa...

Страница 20: ...ncy Can run with differently rated DIMMs and use the settings of the slowest DIMM within a channel Timings other than frequency can vary between channels C PU1 C hannel A C hannel B C hannel C C PU1 C hannel A C hannel B C hannel C C PU1 D IM M 3 A C hannel A C hannel B C hannel C D IM M 2 A D IM M 1 A D IM M 3 B D IM M 2 B D IM M 1 B D IM M 3C D IM M 2C D IM M 1C D IM M 3 A D IM M 2 A D IM M 3 B ...

Страница 21: ...within a channel do not have to be identical but the same memory slot location across channel A and B must be populated the same way C PU1 C hannel A C hannel B C hannel C C PU1 C hannel A C hannel B C hannel C C PU1 D IM M 3 A C hannel A C hannel B C hannel C D IM M 2 A D IM M 1 A D IM M 3 B D IM M 2 B D IM M 3C D IM M 2C D IM M 1C D IM M 3 A D IM M 3 B D IM M 3C D IM M 2C D IM M 1C D IM M 1 A D ...

Страница 22: ...lated for a minimum config uration and for the first two upgrades C hannel A C hannel B C hannel C C PU1 C hannel A C hannel B C hannel C C PU1 C hannel A C hannel B C hannel C C PU1 D IM M 2 A D IM M 1 A D IM M 2 B D IM M 1 B D IM M 2C D IM M 1C D IM M 3 A D IM M 2 A D IM M 1 A D IM M 3 B D IM M 2 B D IM M 1 B D IM M 3C D IM M 2C D IM M 1C D IM M 3 A D IM M 3 B D IM M 2 B D IM M 3C D IM M 2C D IM...

Страница 23: ...opulations within a channel do not have to be identical but the same memory slot location across three channels must be populated the same way Can run with differently rated memory modules and use the settings of the slowest memory module within a channel Timings in the active channels A and B and the spare channel C can be set to different values Only 2 3 of the maximum memory bandwidth is achiev...

Страница 24: ...2 and 4 remain free the slots 3 and 5 can be used as x8 interfaces I Slot 1 is the preferred slot for the HDD controller bootable Figure 6 PCIe slots The following table shows an overview of the PCIe slots PCI slot Description 1 PCIe x4 slot for RAID controller 2 PCIe x4 slot 3 PCIe x4 slot slot 2 free x8 4 PCIe x4 slot 5 PCIe x4 slot slot 4 free x8 6 PCIe x8 slot 7 PCIe x8 slot ...

Страница 25: ...ting In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by the iRMC S2 integrated Remote Management Controller The following functions are supported Temperature monitoring Measurement of the processor and the system internal temperature by an onboard temperature senso...

Страница 26: ...t maximum speed to achieve the greatest possible protection of the hardware Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated System Event Log SEL All monitored events of the system board are signalized via the Global Error LED and recorded in the System Event Log They could be retrieved in the BIOS Setup or via ServerView Diagno...

Страница 27: ...300 S5 Technical Manual 27 Features LEDs 3 6 LEDs Figure 7 LEDs LED s A B C D and E are visible from outside on the rear of the server All the other LEDs are only visible if the cover of the server has been opened ...

Страница 28: ...es a prefailure red flashing indicates a failure Reasons for a failure may be overheating of one of the sensors sensor defect fan defect CPU error software detected an error D LAN activity green connection available green flashing LAN transfer E LAN speed off 10 Mbit s green 100 Mbit s yellow 1000 Mbit s F Controller orange controller failure G CPU orange CPU failure H Memory Module orange memory ...

Страница 29: ...nnectors 3 7 Interfaces and connectors Figure 8 Schematic view of the system board D2619 1 intrusion detection 14 slot for TPM module 2 memory slots for CPU 2 15 SATA1 3 PCIe slots 16 SATA2 4 5 6 7 8 9 11 12 13 20 14 15 16 17 18 19 21 10 22 23 TPM enable 24 25 3 2 1 ...

Страница 30: ... 4 LAN 1 17 front USB 5 LAN 2 18 USB stick 6 Service LAN 19 uSSD 7 USB 1 2 20 USB internal 1 8 USB 3 4 21 USB internal 2 9 VGA 22 power supply 2 10 serial 1 23 power supply1 11 serial 2 24 memory slots for CPU 1 12 front VGA 25 power supply for fans and HDDs 13 front panel ...

Страница 31: ... 1 Gbit s The Service LAN controller supports the transfer rates of 10 Mbit s and 100 Mbit s The LAN controllers support WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN Here Intel PXE and iSCSI boot is supported The service LAN port serves as management interface and is prepared for RemoteView The LAN connectors are equipped each with t...

Страница 32: ...ellow off LAN transfer rate 10 Mbit s green on LAN transfer rate 100 Mbit s yellow on LAN transfer rate 1000 Mbit s 2 LAN link activity green on LAN connection off no LAN connection flashing LAN transfer 1 LAN transfer rate green off LAN transfer rate 10 Mbit s green on LAN transfer rate 100 Mbit s 2 LAN link activity green on LAN connection off no LAN connection flashing LAN transfer 2 1 2 1 ...

Страница 33: ... please call our customer service centre Skipping the password query switch 2 Switch 2 is used to define whether the password is queried at system startup if the password protection is enabled in BIOS Setup in Security menu the Password on boot field must be set to Enabled on The system boots from the Flash BIOS medium floppy disk ODD USB stick and reprograms the system BIOS on the board off The S...

Страница 34: ...er Figure 13 Position of the TPM jumper TPM enable I As default the jumper 1 2 is set Without jumper the TPM function is disabled on The System BIOS can not be written Flash BIOS update from floppy disk is not possible off The System BIOS can be written Flash BIOS update from floppy disk is possible default setting Pin Signal Description 1 TPM RESET L Reset of the TPM module 2 ICH TMP DIS L Reset ...

Страница 35: ...replaced with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trash can It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 14 Replacing the lithium battery Ê Press the locking spring into direction ...

Страница 36: ......

Отзывы: