LEDs
Features
Figure 6: LEDs on the riser card
LED s A, B and C are visible from outside on the rear of the server. All the other
LEDs are only visible, if the cover of the server has been opened.
If the server has been powered off (power-plugs must be disconnected) it is
possible to indicate the faulty component by pressing the indicate CSS button.
The LEDs have the following meaning:
LED Anzeige
Bedeutung
A - CSS
(Customer Self
Service)
yellow
indicates a prefailure
yellow flashing indicates a failure
B - GEL
(Global Error
LED)
orange
indicates a prefailure
orange
flashing
indicates a failure. Reasons for a failure
may be:
- overheating of one of the sensors
- sensor defect
- fan defect
- CPU error
- voltage incorrect
- Software detected an error
C - Identification blue
server is identified via ServerView