System Board D2529
for TX300 S4  

Technical Manual

Edition November 2007

Содержание D2529

Страница 1: ...System Board D2529 for TX300 S4 Technical Manual Edition November 2007 ...

Страница 2: ...a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2007 Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to av...

Страница 3: ... 10 2 3 Environmental Protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 17 3 3 PCI e slots 20 3 4 Screen resolution 23 3 5 Temperature system monitoring 23 3 6 LEDs 25 3 7 Interfaces and connectors 28 3 7 1 External ports 30 3 8 Settings with DIP switches 32 4 Replacing the lithium battery 35 Abbreviations 37 ...

Страница 4: ......

Страница 5: ...ixed font indicate system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key sy...

Страница 6: ......

Страница 7: ...Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging ...

Страница 8: ...As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosion...

Страница 9: ...ouching a grounded object before working The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you inst...

Страница 10: ... when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp ...

Страница 11: ...and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the househol...

Страница 12: ...D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable througho...

Страница 13: ...y riser cards with 8 PCI slots each FBD PC2 4200F or FDB PC2 5300F Fully Buffered DIMM memory modules with 512 MB 1 Gbyte 2 Gbyte and 4 Gbyte Maximum 64 Gbyte Minimum 1 Gbyte Maximum 4x8 Gbyte s bandwidth Supports 4 FBD memory channels ECC multiple bit error detection and single bit error correction Memory scrubbing function Single Device Data Correction SDDC function Chipkill Mirroring Sparing Ch...

Страница 14: ... streamer 4 fan direct connectors 1 connector for 2 CPU fans Intrusion connector 2 slots for memory riser cards 1 SMB connector 1 HD LED activity connector External connectors 2 serial ports COM1 COM2 1 parallel port optional 2 PS 2 interfaces for keyboard and mouse 2 UHCI USB 2 0 ports with 480 Mbits s rear side combined with 1 RJ45 LAN connector dedicated service LAN 1 VGA port 1 dual RJ45 LAN c...

Страница 15: ...lder for recycling Form factor 290 x 460 mm ACPI 2 0 OnNow PCI X 1 0b PCI Express 1 0a LPC 1 1 WfM 2 0 SHDG 3 0 MPS 1 4 IPMI 2 0 and PCI Express Card Electromechanical Specification Rev 1 0 USB2 0 SATAII 1 0 CSS Customer Self Service This system board supports the CSS functionality You will find a description of CSS functionality in the operating manual of your server TPM option The system board i...

Страница 16: ...rovided by the third party manufacturers You must also create a backup of the TPM content To do this follow the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data If a failure occurs please inform your service about the TPM activation before it takes any action and be prepared to provide them with your backu...

Страница 17: ...byte 2 Gbyte or 4 Gbyte FBD PC2 4200F or FDB PC2 5300F fully buffered DIMM memory modules ECC with memory scrubbing and with the Single Device Data Correction SDDC function is supported I You will find the descriptions how to install memory modules in the Options Guide of your server Slots for riser cards Figure 2 Slots for the riser cards If only one riser card is occupied slot DIMM A B will be p...

Страница 18: ...5300 Fully Buffered DIMM memory modules Each pair consists of identical memory modules There are three modes of operation for the main memory Non mirrored mode Mirrored mode Sparing mode Depending on the mode of operation there are different population requiren ments DIMM 2D DIMM 2C DIMM 1D DIMM 1C DIMM 4D DIMM 4C DIMM 3C DIMM 3D DIMM 2B DIMM 2A DIMM 4B DIMM 4A DIMM 3A DIMM 3B DIMM 1B DIMM 1A DIMM...

Страница 19: ...s in matched sets of four two in each riser card 1A 1B 1C 1D minimum configuration 2A 2B 2C 2D upgrade 1 3A 3B 3C 3D upgrade 2 4A 4B 4C 4D upgrade 3 Riser card A B Riser card C D Alternating population 1A 1B minimum configuration Upgrade 1 1C 1D Upgrade 2 2A 2B Upgrade 3 2C 2D Upgrade 4 3A 3B Upgrade 5 3C 3D Upgrade 6 4A 4B Upgrade 7 4C 4D Consecutive population 1A 1B minimum configuration Upgrade...

Страница 20: ...A 2B minimum configuration bank 2 in hotspare mode 1A 1B 2A 2B 3A 3B upgrade 1 bank 3 in hotspare mode 1A 1B 2A 2B 3A 3B 4A 4B upgrade 2 bank 4 in hotspare mode 3 3 PCI e slots Figure 4 Mechanical PCI slots the PCI slot numbers on the rear Slot 1 PCI Express Slot 2 PCI Express Slot 3 PCI Express Slot 5 PCI Express Slot 6 PCI Express Slot 7 PCI Express Slot 4 PCI X 4 5 6 7 3 2 1 ...

Страница 21: ...ing on the functionality PCI and PCI X buses use four lines named INTA to INTD typically connected to all devices on the bus in order to periodically balance interrupt load An interrupt signal may thereby be used simultaneously by multiple devices interrupt sharing PCI Express devices send their interrupts through messages The interrupts are defined by the system design PCI slot Bit Frequency in M...

Страница 22: ...are assigned automatically and no further settings are required Slot device Property Interruptsignal VGA iRMC Grafik Int A LAN 1 BCM5708 Int B LAN 2 BCM5708 Int C Steckplatz 7 PCI e x4 Int A B C D Steckplatz 6 PCIe x8 Int A B C D Steckplatz 5 PCIe x4 Int A B C D Steckplatz 4 PCI 133 MHz Int A B C D Steckplatz 3 PCIe x8 Int A B C D Steckplatz 2 PCIe x4 Int B C D A Steckplatz 1 PCIe x4 Int A B C D ...

Страница 23: ... to reliably protect the computer hardware against damage and to provide any information about the system status Temperature and system monitoring is managed via an onboard controller The following functions are supported Temperature monitoring Measurement of the processor and the system board internal temperature by a temperature sensor measurement of the ambient temperature by a I2 C temper atur...

Страница 24: ...he internal voltages If one of the internal voltages reaches its upper or lower threshold an alarm is generated Cover monitoring Unauthorized opening of the cover is detected even when the system is switched off power down mode However this will only be indicated when the system is switched on again System Event Log SEL All monitored events of the system board are signalized via the Global Error L...

Страница 25: ...25 Features LEDs 3 6 LEDs Figure 5 LEDs on the system board North bridge South bridge System Fan 2 System Fan 1 System Fan 3 System Fan 4 CPU 1 2 Fans CPU 1 CPU 2 CPU Fan 2 CPU Fan 1 A B N M N M C K G D D D D D D D I H E E F F F F F F ...

Страница 26: ...tton The LEDs have the following meaning LED Anzeige Bedeutung A CSS Customer Self Service yellow indicates a prefailure yellow flashing indicates a failure B GEL Global Error LED orange indicates a prefailure orange flashing indicates a failure Reasons for a failure may be overheating of one of the sensors sensor defect fan defect CPU error voltage incorrect Software detected an error C Identific...

Страница 27: ...C not active H Board Error red configuration error The system board will be held in reset Possible configuration errors are e g old CPU populated CPUs with different FSB requirements populated CPU1 not populated I Main Power green system running K Aux Power yellow auxiliary power ok off auxiliary power not available L Memoryr off memory module ok orange error in memorymodule M LAN Trans ferrate ye...

Страница 28: ...s and connectors Features 3 7 Interfaces and connectors Figure 7 Schematic view of the system board D2529 System Fan 1 System Fan 3 System Fan 2 System Fan 4 CPU 1 CPU 2 CPU Fan 2 CPU Fan 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ...

Страница 29: ...TA2 3 slots for main memory modules 14 CPU 1 2 fan 4 Power supply PWR2 15 Intrusion 5 Power supply PWR3 16 USB 2 AUX 6 PC98 17 USB 1 AUX 7 Power supply PWR1 18 CSS push button 8 Front panel 19 USB intern 9 USB front 20 DIP Schalter siehe page 32 10 Floppy disk drive 21 HD LED 11 SATA1 22 LPC bus for assembly only ...

Страница 30: ...used as default interface or to communicate with the iRMC 1 Printer port optional 7 USB port 4 2 PS 2 mouse connector 8 VGA port 3 LAN connector service LAN 9 Serial interface COM1 4 LAN connector 2 10 Serial interface COM2 5 LAN connector 1 11 PS 2 keyboard connector 6 USB port 3 12 CSS LED yellow Global Error LED orange Identifications LED blue 6 5 8 7 10 9 11 12 3 4 1 2 ...

Страница 31: ...addition system LAN 1 can be used as shared service LAN 1 dedicated service LAN controller supports the transfer rates of 10 Mbit s and 100 Mbit s serves as management interface is prepared for RemoteView The LAN connectors are equipped each with two LEDs light emitting diode indicating the transfer rate and the activity Figure 9 LAN connector single channel Gigabit LAN controller LAN 1 LAN transf...

Страница 32: ...ate has failed To restore the old system BIOS you need a Flash BIOS medium please call our customer service centre LAN 1 LAN transfer rate green off transfer rate 10 Mbit s green on transfer rate 100 Mbit s LAN 2 LAN link activity green on LAN connection off no LAN connection flashing LAN transfer on The system boots from the Flash BIOS medium floppy disk DVD CD ROM USB sstick and reprograms the s...

Страница 33: ... used to define whether floppy disks can be written or deleted in the floppy disk drive To write and delete floppy disks the write protection in BIOS Setup must be disabled in menu Security the field Diskette Write must be set to Enabled on The password query is skipped Passwords are deleted off The password query is effective default setting on The System BIOS can neither be written to nor delete...

Страница 34: ...34 Technical Manual D2529 TX300 S4 Settings with DIP switches Features ...

Страница 35: ...eplaced with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trash can It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 12 Replacing the lithium battery Ê Press the locking spring into direction o...

Страница 36: ......

Страница 37: ...tions listed here are valid for the described system board ACPI Advanced Configuration and Power Interface ASR R Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CPU Central Processing Unit DDR Double Data Rate DIMM D...

Страница 38: ...r Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD FBD Fully Buffered DIMM HPC Hot plug Controller ICE In Circuit Emulation IDE Integrated intelligent Drive Electronics IME Integrated Mirror Enhanced IOOP Intelligent Organization Of PCI ...

Страница 39: ...te Management Controller iSCSI internet Small Computer System Interface LAN Local Area Network LED Light Emitting Diode LPC Low Pin Count MPS Multi Processor Specification MTS MegaTransfers per Second NMI Non Maskable Interrupt OEM Original Equipment Manufacturer OHCI Open Host Controller Interface OS Operating System PCI Peripheral Components Interconnect ...

Страница 40: ...D Programmable Logic Device PS U Power Supply Unit PWM Puls Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interface SDDC Single Device Data Correction ...

Страница 41: ...Design Guide SMB System Management Bus SMM Server Management Mode SMP Symmetrically Multi Processing TMP Trusted Platform Module UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module WfM Wired for Management WOL Wake up On LAN ...

Страница 42: ......

Страница 43: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...