Содержание D2519

Страница 1: ...System Board D2519 for RX300 S4 Technical Manual Edition August 2008 ...

Страница 2: ... a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2008Fujitsu Siemens Computers GmbH All rights reserved Delivery subject to av...

Страница 3: ...cate 10 2 3 Environmental Protection 11 3 Features 13 3 1 Overview 13 3 2 Main memory 16 3 3 PCI bus 19 3 4 Screen resolution 21 3 5 Temperature system monitoring 21 3 6 LEDs 23 3 7 Interfaces and connectors 26 3 7 1 External ports 27 3 8 Settings with jumpers 30 4 Replacing the lithium battery 33 Abbreviations 35 ...

Страница 4: ......

Страница 5: ...ont indicate system output on the monitor semi bold fixed font indicates values to be entered through the keyboard Key symbol indicates keys according to their representation on the keyboard If capital letters are to be entered explicitly then the Shift key is shown e g SHIFT A for A If two keys need to be pressed at the same time then this is shown by placing a hyphen between the two key symbols ...

Страница 6: ......

Страница 7: ...Any failure to observe the guidelines in this manual and any unauthorized openings and improper repairs could expose the user to risks electric shock fire hazards and could also damage the equipment Please note that any unauthorized openings of the device will result in the invalidation of the warranty and exclusion from all liability Transport the device only in the antistatic original packaging ...

Страница 8: ...As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Never connect or disconnect data transmission lines during a storm lightning hazard Batteries V CAUTION Incorrect replacement of lithium battery may lead to a risk of explosion...

Страница 9: ...ouching a grounded object before working The equipment and tools you use must be free of static charges Remove the power plug from the power socket before inserting or removing boards containing ESDs Always hold boards with ESDs by their edges Never touch pins or conductors on boards fitted with ESDs Use a grounding cable designed for this purpose to connect yourself to the system unit as you inst...

Страница 10: ... when you insert or remove boards Take great care to ensure that extension boards are slotted in straight without damaging components or conductors on the system board or any other components for example EMI spring contacts Be careful with the locking mechanisms catches centring pins etc when you replace the system board or components on it for example memory modules or processors Never use sharp ...

Страница 11: ...and should be switched off during long breaks and on completion of work Notes on packaging Please do not throw away the packaging We recommend that you do not throw away the original packaging in case you need it later for transporting Notes on dealing with consumables Please dispose batteries in accordance with local government regulations Do not throw batteries and accumulators into the househol...

Страница 12: ...D 33106 Paderborn Tel 49 5251 8 18010 Fax 49 5251 8 18015 The device may not be disposed of with household rubbish This appliance is labelled in accordance with European Directive 2002 96 EC concerning used electrical and electronic appliances waste electrical and electronic equipment WEEE The guideline determines the framework for the return and recycling of used appliances as applicable througho...

Страница 13: ...fered DIMM memory modules with 512 MB 1 Gbyte 2 Gbyte and 4 Gbyte single rank maximum 48 Gbyte of memory minimum 1 Gbyte 2 memory modules Support of 4 FBD memory channels minimum 32 Gbyte bandwidth ECC multiple bit error detection and single bit error correction Memory scrubbing functionality Single Device Data Correction SDDC function Chipkill Mirroring Sparing Chips on the system board Intel Bla...

Страница 14: ...ne print 26 pin 2 serial SATA 1 universal USB connector 1 USB connector for USB stick 2 x USB for USB connectors at the front SATA 1 4 multilane HDD Activity LED front panel 8 direct fan connectors power 12V 12V 5V 3 3V and 5V auxiliary Combined connector for 12V CPU power and PC98 SMB 2 x slots for riser memory modules PCI slots 1 x PCI X 6 x PCI Express BIOS features Phoenix System BIOS V 4 06 S...

Страница 15: ...ical Specification Rev 1 0 USB2 0 SATAII 1 0 CSS Customer Self Service This system board supports the CSS functionality You will find a description of CSS functionality in the operating manual of your server TPM option The system board is optional equipped with a TPM Trusted Platform Module by the manufacturer This module enables programs from third party manufac turers to store key information e ...

Страница 16: ... the third party manufacturer s instructions Without this backup if the TPM or the system board is faulty you will not be able to access your data If a failure occurs please inform your service about the TPM activation before it takes any action and be prepared to provide them with your backup copies of the TPM content ...

Страница 17: ... DIMM memory modules ECC with memory scrubbing and with the Single Device Data Correction SDDC function is supported I You will find the descriptions how to install memory modules in the Options Guide of your server Module population Figure 2 Assembly of the main memory with memory banks and memory modules O when LED is ON the memory module is faulty DIMM 3D DIMM 3C DIMM 2D DIMM 2C DIMM 1D DIMM 1C...

Страница 18: ...fered DIMM modules FBD PC2 4200 or FBD PC2 5300 One pair of memory modules must consist of identical memory modules The module capacity between pairs can differ pair 2A 2B can be populated with two 512 Mbyte modules and pair 1A 1B with two 1 Gbyte modules Bank 1 ï DIMM 1A 1B Bank 2 ï DIMM 2A 2B Bank 3 ï DIMM 3A 3B Bank 5 ï DIMM 1C 1D Bank 6 ï DIMM 2C 2D Bank 7 ï DIMM 3C 3D ...

Страница 19: ...h one riser card the mandatory population order is 1A 1B minimum configuration 2A 2B 3A 3B With two riser cards the population can be made as well alternately as consec utively I Alternate population is recommended First riser card Second riser card Alternate population 1A 1B minimum configuration 1C 1D 2A 2B 2C 2D 3A 3B 3C 3D Consecutive population 1A 1B minimum configuration 2A 2B 3A 3B 1C 1D 2C...

Страница 20: ... Manual D2519 RX300 S4 Main memory Features Mirrored mode In mirrored mode always four identical memory modules are necessary two in each riser card 1A 1B 1C 1D minimum configuration 2A 2B 2C 2D 3A 3B 3C 3D upgrade ...

Страница 21: ...CI slots PCI slot 32bit Frequency in MHz Description 1 PCI e x4 slot 2 PCI e x4 slot 3 PCI e x4 slot slot 3 free x8 4 64 bit 133 32 Bit PCI slot 5 PCI e x4 slot 6 PCI e x4 slot slot 5 free x8 7 PCI e x4 slot Slot3 PCI Express Slot4 PCI X Slot1 PCI Express Slot2 PCI Express Slot7 PCI Express Slot5 PCI Express Slot6 PCI Express 1 2 3 4 5 6 7 ...

Страница 22: ...ress devices send their interrupts through messages This avoids restrictions in wiring The following interrupt signals are used in the system I Slot 1 is the preferred slot for the HDD controller bootable Assignment of the PCI interrupts If you select Auto in the BIOS setup the interrupts are assigned automatically and no further settings are required Slot device Property Interrupt signal VGA iRMC...

Страница 23: ... damage caused by overheating In addition any unnecessary noise is also prevented by reducing the fan speed and information is provided about the system status The temperature and system monitoring are controlled by an onboard controller The following functions are supported Temperature monitoring Measurement of the processor and the system internal temperature by an onboard temperature sensor mea...

Страница 24: ...maximum speed to achieve the greatest possible protection of the hardware Voltage monitoring When voltage exceeds warning level high or falls below warning level low an alert will be generated System Event Log SEL All monitored events of the system board are signalized via the Global Error LED and recorded in the System Event Log They could be retrieved in the BIOS Setup or via ServerView Diagnost...

Страница 25: ...C D E and F are visible from outside on the rear of the server All the other LEDs are only visible if the cover of the server has been opened CPU 1 Fan 1 CPU Fan 4 CPU Fan 2 CPU Fan 3 CPU Fan 1 sys Fan 5 CPU Fan 6 CPU Fan 2 sys MCH ESB2 CPU 2 G L K M F D H A B C I I I I D E N Battery ...

Страница 26: ...t CPU error Software detected an error C Identification blue server is identified via ServerView D LAN activity green connection available green flashing LAN transfer E LAN speed service off 10 Mbps green 100 Mbps F LAN speed off 10 Mbps green 100 Mbps yellow 1000 Mbps G Controller orange controller failure H CPU orange CPU failure I FAN green fan OK orange fan failure K iRMC green flashing iRMC i...

Страница 27: ...519 RX300 S4 Technical Manual 27 Features LEDs By pressing the CSS tracer to position see next side the defective component can also be indicated in the power off condition power supply plug discon nected ...

Страница 28: ...rs Features 3 7 Interfaces and connectors Figure 5 Schematic view of the system board D2519 CPU 1 Fan 1 CPU Fan 4 CPU Fan 2 CPU Fan 3 CPU Fan 1 sys Fan 5 CPU Fan 6 CPU Fan 2 sys MCH ESB2 CPU 2 Battery 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 23 24 ...

Страница 29: ...12V 17 system fan 2 6 CPU fan 4 18 system fan 1 7 front panel 19 CSS button 8 SATA1 20 USB stick 9 CPU fan 2 21 DIP switch see page 32 10 CPU fan 5 22 HDD activity 11 floppy disk drive 23 PCI slots 12 USB 24 external connectors 1 CSS LED yellow Global Error LED red Identification LED blue 6 USB port 1 2 PS 2 mouse connector 7 USB port 2 3 service LAN connector 8 VGA port 4 system LAN connector 1 9...

Страница 30: ...of 10 Mbit s and 100 Mbit s The LAN controllers support WOL function through Magic Packet It is also possible to boot a device without its own boot hard disk via LAN Here Intel PXE is supported The service LAN port serves as management interface and is prepared for RemoteView The LAN connectors are equipped each with two LEDs light emitting diode indicating the transfer rate and the activity Figur...

Страница 31: ...erfaces and connectors Figure 8 LAN connector service LAN controller 1 LAN transfer rate green off transfer rate 10 Mbit s green on transfer rate 100 Mbit s 2 LAN link activity green on LAN connection off no LAN connection flashing LAN transfer 2 1 ...

Страница 32: ...o Enabled Write protection for Flash BIOS switch 3 Switch 3 is used to define whether the System BIOS is write protected or not on The system boots from the Flash BIOS medium optional floppy disk ODD USB stick and reprograms the system BIOS on the board off The System BIOS is started with the system BIOS from the system board default setting on The password query is skipped Passwords are deleted o...

Страница 33: ...ine whether floppy disks can be written or deleted in the floppy disk drive To write and delete floppy disks the write protection in BIOS Setup must be disabled in menu Security the field Diskette Write must be set to Enabled on The floppy disk drive is write protected off Floppy disks can be read written and deleted default setting ...

Страница 34: ...34 Technical Manual D2519 RX300 S4 Settings with jumpers Features ...

Страница 35: ...eplaced with an identical battery or a battery type recommended by the manufacturer CR2450 Do not throw lithium batteries into the trash can It must be disposed of in accordance with local regulations concerning special waste Make sure that you insert the battery the right way round The plus pole must be on the top Figure 10 Replacing the lithium battery Ê Press the locking spring into direction o...

Страница 36: ......

Страница 37: ...viations listed here are valid for the described system board ACPI Advanced Configuration and Power Interface ASR R Automatic Server Recovery and Restart ATA Advanced Technology Attachment BBU Battery Backup Unit BIOS Basic Input Output System BMC Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COM COMmunication port CSS Computer Self Service CPU Central Processing Uni...

Страница 38: ...nterface DMA Direct Memory Access DRAM Dynamic Random Access Memory ECC Error Correction Code EEPROM Electrical Erasable Programmable Read Only Memory EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic FBD Fully Buffered DIMM FSB Front Side Bus EVRD Enterprise VRD HPC Hot plug Controller ICE In Circuit Emulation ...

Страница 39: ...I IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface iRMC integrated Remote Management Controller LAN Local Area Network LED Light Emitting Diode MPS Multi Processor Specification NMI Non Maskable Interrupt NVRAM Non Volatile RAM OEM Original Equipment Manufacturer ODD Optical Disk Drive OHCI Open Host Controller Interface ...

Страница 40: ... Prefailure Detection and Analyzing PIO Programmed Input Output PLD Programmable Logic Device PS U Power Supply Unit PWM Puls Wide Modulation PXE Preboot eXecution Environment RAID Redundant Array of Inexpensive Disks RSB Remote Service Board RST ReSeT RTC Real Time Clock SAS Serial Attached SCSI SATA Serial ATA ...

Страница 41: ...andom Access Memory SHDG Server Hardware Design Guide SHPC Standard Hot Plug Controller SMB System Management Bus SMM Server Management Mode SMP Symmetrically Multi Processing TPM Trusted Platform Module UHCI Unified Host Controller Interface USB Universal Serial Bus VGA Video Graphics Adapter VRD Voltage Regulator Down VRM Voltage Regulator Module ...

Страница 42: ...WfM Wired for Management WOL Wake up On LAN ...

Страница 43: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...