- (01 - 05) -
C
EI
LI
N
G W
A
LL T
YP
E
A
W
Z14
-2
4L
B
C
EI
LI
N
G W
A
LL T
YP
E
A
W
Z14
-2
4L
B
SPECIFICATIONS
31
Type
CEILING WALL
INVERTER HEAT PUMP
Model name
AW
Z14LBC
AW
Z18LBC
AW
Z24LBC
Power source
230V~ 50Hz
Available voltage range
198-264V~ 50Hz
European energy label
Cooling
A
A
A
Heating
A
A
A
Capacity
Cooling
Rated
kW
4.20
5.20
7.10
BTU/h
14,300
17,700
24,200
Min.-Max.
kW
0.9-5.3
0.9-5.9
0.9-8.0
BTU/h
3,100-18,100
3,100-20,100
3,100-27,300
Heating
Rated
kW
6.00
6.70
8.50
BTU/h
20,500
22,900
29,000
Min.-Max.
kW
0.9-9.1
0.9-9.7
0.9-11.0
BTU/h
3,100-31,000
3,100-33,100
3,100-37,500
Input power
Cooling
Rated
kW
1.02
1.58
2.21
Min.-Max.
0.09-1.75
0.09-2.00
0.11-2.62
Heating
Rated
1.35
1.63
2.35
Min.-Max.
0.09-2.95
0.09-3.20
0.11-3.68
Current
Cooling
Rated
A
4.5
6.9
9.7
Max.*
8.5
8.5
12.5
Heating
Rated
5.9
7.2
10.3
Max.*
14.0
14.0
17.5
EER
Cooling
kW/kW
4.12
3.29
3.21
COP
Heating
4.44
4.11
3.62
SENSIBLE CAPACITY
Cooling
kW
2.80
3.30
5.10
POWER FACTOR
Cooling
%
98
99
99
Heating
99
99
99
Moisture removal
l/h (pints/h)
2.1 (3.7)
2.8 (4.9)
3.0 (5.3)
Fan
Airflow rate
Cooling
High
m
3
/h
850
850
880
Med
760
760
780
Low
580
580
700
Quiet
465
465
620
S-Quiet
365
365
560
Heating
High
940
940
980
Med
740
740
880
Low
605
605
780
Quiet
510
510
700
S-Quiet
390
390
605
Type × Q'ty
Cross flow fan × 1
Motor output
W
72
Sound pressure level
Cooling
High
dB (A)
46
46
47
Med
43
43
43
Low
35
35
40
Quiet
29
29
36
S-Quiet
24
24
32
Heating
High
46
46
47
Med
39
39
43
Low
34
34
40
Quiet
29
29
36
S-Quiet
24
24
32
Heat exchanger type
Dimensions (H × W × D)
mm
315 × 750 × 26.6
Fin pitch
1.2
Rows × Stages
2 × 15
Pipe type
Copper
Fin type
Aluminium
Enclosure
Material
Polystyrene
Colour
White
Dimensions
(H × W × D)
Net
mm
250 × 899 × 298
Gross
356 × 960 × 378
Weight
Net
kg (lb.)
13.5 (30)
Gross
17 (37)
Connection pipe Size
Liquid
mm
Φ6.35 (Φ1/4 in.)
Φ6.35 (Φ1/4 in.)
Gas
Φ12.7 (Φ1/2 in.)
Φ15.88 (Φ5/8 in.)
Method
Flare
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
30 or less
Remote controller type
Wireless
Drain pipe
Material
PP+LLDPE
Size
mm
Outer diameter : 29 / Inner diameter : 13.6
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB. and outdoor temperature of 35°CDB/24°CWB.
Heating : Indoor temperature of 20°CDB / 15°CWB. and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 7.5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
The maximum current is the maximum value when operated within the operation range (temperature).
*
The maximum current is the total current of indoor unit and outdoor unit.