- (04 - 06) -

4-4. DIMENSIONS
4-4-1. OUTDOOR UNIT

MODEL : AOU42R

MOUNTING POSITION

Unit : in.(mm)

35-7/16 (900)

50

-2

5/

32

 (1

29

0)

3-1/32

(77)

1-7/32

(31)

15/32

(12)

13

/1

6

(2

1)

11

/3

2

(9

)

14

-7

/8

 (3

70

)

15-3/4 (400)

25-19/32 (650)

5-15/16 (151)

6-11/16 (170)

3-

29

/3

(9

9)

7-

23

/3

2

(1

96

)

4-Ø15/32 (12) hole

13 (330)

Air flow

Drain cap 

mounting places

Drain cap 

mounting place

Top view

Side view

Bottom view

Front view

When there are 

obstacles at the 

back or front side.

When there are obstacles 

at the back and front sides.

When there are obstacles at 

the back, side(s), and top.

When there are obstacles 

at the back side with the 

installation of more than 

one unit.

23-5/8 (600)

or more

9-27/32 (250)

or more

9-27/32 (250)

or more

11-13/16

(300) or more

11-13/16 (300)

or more

23

-5

/8

 to

 3

9-

3/

8

(6

00

 to

 1

00

0)

3-15/16 (100)

or more

3-15/16 to 11-13/16

(100 to 300)

3-15/16 (100)

or more

9-27/3

2(250

) or m

ore

(Serv

ice sp

ace)

* If the space is larger than that is stated, the 

condition will be the same as that there are no 

obstacles.

Содержание AUU42R

Страница 1: ...R410A 4 CASSETTE TYPE AUU42RCLX D2D_AU021E 02 2006 04 21 ...

Страница 2: ...e same settings Connectable quantity Maximum 16 indoor units for 1 remote controller Group controller The control box is easily accessible for maintenance work Wide opening for easy access Detachable washable filter and intake grille Wide opening and long life filter Long life filter High efficiency long life filter extends the cleaning cycle Long life filter Slim type intake grille can fit the ce...

Страница 3: ...TTE TYPE AUU42R 04 02 Fresh air can be introduced through this opening Duct connection hole opening Conditioned air can be distributed by means of a distribution duct Distribution duct Distribution duct Fresh air One way Two way ...

Страница 4: ...ible Easy installation with a slim shape with no boldge in the back When setting up a timer operation mode and a temperature setup can be changed Error indication A maximum of 16 error histories are memorizable Built in room temperature sensor 0 3 6 9 12 15 18 21 75 F 24 C 75 F 24 C 0 3 6 9 12 15 18 21 82 F 28 C 82 F 28 C Screen after setup Setup screen example Set from Sunday to Saturday PM12 00 ...

Страница 5: ...s the date hour minute and on off time 12 8 Set back button Vertical air flow direction and swing button Push for two seconds to change the swing mode Central control display 9 Timer mode CLOCK ADJUST button Set time button Pessed to select the set back timer Master control button Selects the operating mode AUTO HEAT FAN COOL DRY 4 3 Fan control button Selects the fan speed AUTO LOW MED HIGH 18 Te...

Страница 6: ...F 35 C DB 75 2 F 24 C WB Heating Indoor temperature of 68 0 F 20 C DB 59 0 F 15 C WB and outdoor temperature of 44 6 F 7 C DB 42 8 F 6 C WB Pipe length 24ft 7in 7 5m Height difference 0 ft 0m Outdoor unit Indoor unit Rows x Stages INDOOR OUTDOOR SEER HSPF OUTPUT Rows x Stages WIRED ABS Outer diameter 37 0 1 15 32 7lb 7 15 16oz 3400 POE 0 to 115 18 to 46 0 to 75 18 to 24 R410A Aluminium 2 60 22 38 ...

Страница 7: ... Front view When there are obstacles at the back or front side When there are obstacles at the back and front sides When there are obstacles at the back side s and top When there are obstacles at the back side with the installation of more than one unit 23 5 8 600 or more 9 27 32 250 or more 9 27 32 250 or more 11 13 16 300 or more 11 13 16 300 or more 23 5 8 to 39 3 8 600 to 1000 3 15 16 100 or m...

Страница 8: ... 11 16 830 Bottom view Unit in mm Side view Slender setting Side view 11 21 32 296 37 940 1 3 16 30 2 3 8 60 11 7 32 285 4 23 32 120 5 29 32 150 Small pipe Drain pipe Large pipe 9 27 32 250 37 940 12 1 32 305 5 11 3 4 298 5 9 25 32 248 5 Drain Inside Dia 32mm Dia 37mm Outside Bottom view Panel Side view Standard setting ...

Страница 9: ... or more 3 15 16 100 or more 4 directions 3 directions Piping position 2 directions 2 directions You can select 2 way setting A Standard setting B Slender setting 39 3 8 1 000 or more Strong and durable ceiling 47 1 4 1 200 or more 96 2 400 or more Obstruction 11 13 16 300 or more 10 7 16 265 or more Floor Unit in mm ...

Страница 10: ...CASSETTE TYPE AUU42R CASSETTE TYPE AUU42R 04 09 4 5 REFRIGERANT CIRCUIT MODELS AUU42R AOU42R ...

Страница 11: ...CASSETTE TYPE AUU42R CASSETTE TYPE AUU42R 04 10 4 6 WIRING DIAGRAMS 4 6 1 OUTDOOR UNIT MODEL AOU42R TO INDOOR UNIT G G TEMP TEMP TEMP TEMP TEMP TO POWER SUPPLY ...

Страница 12: ...CASSETTE TYPE AUU42R CASSETTE TYPE AUU42R 04 11 4 6 2 INDOOR UNIT MODEL AUU42R G N ...

Страница 13: ...temperature 54 FWB 60 FWB 63 FWB 64 FDB 70 FDB 75 FDB AFR Air flow rate CFM TC Total capacity kBTU 71 FWB 73 FWB 90 FDB 80 FDB 85 FDB Indoor temperature AFR 28 3 CDB TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 17 78 11 38 7 66 2 21 12 83 7 71 2 24 13 56 8 45 2 26 14 53 8 84 2 29 15 50 9 13 2 31 15 98 10 12 2 33 10 00 11 22 7 55 2 34 12 66 7 59 2 38 13 37 8 32 2 40 14 33 8 71 2 43 1...

Страница 14: ...DB 65 FDB 70 FDB Outdoor temperature AFR Air flow rate CFM TC Total capacity kBTU 60 FDB 78 FDB AFR 28 3 CDB CWB TC PI TC PI TC PI TC PI TC PI 17 78 18 33 10 64 4 71 10 30 4 85 9 95 4 99 9 60 5 13 9 40 5 21 10 00 11 11 12 59 4 71 12 18 4 85 11 77 4 99 11 36 5 13 11 12 5 21 5 00 7 22 14 09 4 71 13 64 4 85 13 18 4 99 12 72 5 13 12 45 5 21 0 00 2 22 15 44 4 71 14 94 4 85 14 44 4 99 13 94 5 13 13 64 5...

Страница 15: ...t 0 910 0 878 0 852 0 830 0 810 0 791 30m 98 ft 0 863 0 838 0 817 0 797 0 778 COOLING Outdoor unit is up side PIPE LENGTH HEIGHT DIFFERENCE Outdoor unit is bottom side 5 m 7 5 m 10 m 20 m 30 m 40 m 50 m 60 m 70 m 16 ft 25 ft 33 ft 66 ft 98 ft 131 ft 164 ft 197 ft 230 ft 30m 98 ft 0 923 0 912 0 899 0 886 0 874 20m 66 ft 0 949 0 933 0 921 0 908 0 896 0 883 10m 33 ft 0 980 0 958 0 942 0 931 0 917 0 9...

Страница 16: ...NT CHARGE ft 66 98 131 164 197 230 MAX m 20 30 40 50 60 70 MAX lb oz 0 Charge less 14 1 8 oz 1 lb 12 7 32 oz 2 lb 10 11 32 oz 3 lb 8 7 16 oz 4 lb 6 9 16 oz g 0 Charge less 400 800 1200 1600 2000 ADDITIONAL CHARGE PIPE LENGTH 1 13 32oz ft 40g m REFRIGERANT TYPE REFRIGERANT AMOUNT lb oz g R410A 7 lb 7 15 16 oz 3400 ...

Страница 17: ...RATION RANGE Indoor unit Outdoor unit Indoor temperature Indoor humidity Outdoor temperature Cooling Dry 64 to 88 F 18 to 31 C About 80 or less 0 to 115 F 18 to 46 C Heating 60 to 88 F 16 to 31 C 0 to 75 F 18 to 24 C AUU42R AOU42R Model Mode Operation Range ...

Страница 18: ...t m 7 2 3 1 0 0 ft m 7 2 3 1 0 0 ft m 3 1 0 0 3 1 7 2 3 1 0 0 3 1 7 2 10 3 7 2 7 2 7 2 7 2 3 1 3 1 3 1 3 1 2 0 5 2 0 5 7 2 7 2 7 2 7 2 7 2 7 2 7 2 7 2 3 1 3 1 3 1 3 1 3 1 3 1 3 1 3 1 2 0 5 2 0 5 2 0 5 2 0 5 2 0 5 2 0 5 2 0 5 2 0 5 13 16 0 25 2 0 5 m ft m ft 2 1 0 1 2 7 3 0 3 7 m ft m ft m ft 2 WAY AIR OUTLET 2 0 5 13 16 0 25 13 16 0 25 13 16 0 25 13 16 0 25 13 16 0 25 8 7 6 5 4 3 2 1 0 1 2 3 4 5 6...

Страница 19: ...42R CASSETTE TYPE AUU42R m 3 h 1700 l s 472 CFM 1000 m 3 h 1450 l s 403 CFM 853 m 3 h 1250 l s 347 CFM 736 LOW 650 610 530 FAN SPEED NUMBER OF ROTATIONS r p m AIR FLOW Outdoor unit HIGH CFM Lower fan Indoor unit HIGH MED 3884 Upper fan 850 m 3 h 6600 l s 1833 750 ...

Страница 20: ...WG Pa 0 2 4 6 8 10 0 3 32 5 32 1 4 5 16 13 32 0 24 58 8 0 16 39 2 0 08 19 6 0 0 mmAq in Ag m3 min ft 3 min 0 0 1 0 2 0 3 0 4 0 5 0 6 0 4 7 11 14 18 21 in WG Pa 0 1 2 4 5 0 3 32 5 32 3 6 1 4 7 L Duct Inside Dia 3 15 16 100mm Duct Inside Dia 2 3 4 70mm Static pressure required to take in fresh air Duct Fan P DUCT STATIC PRESSURE DUCT STATIC PRESSURE DUCT STATIC PRESSURE OUTLET AIR FRESH AIR 4 11 3 D...

Страница 21: ...evel dB 0dB 0 0002µbar Octave band limiting frequency Hz Octave band sound pressure level dB 0dB 0 0002µbar Octave band limiting frequency Hz 0 10 20 30 40 50 60 70 80 CASSETTE TYPE AUU42R CASSETTE TYPE AUU42R NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 COOLING MODEL AOU42R HEATING MODEL AOU42R ...

Страница 22: ...CASSETTE TYPE AUU42R CASSETTE TYPE AUU42R 04 21 SOUND LEVEL CHECK POINT 3ft 3 3 8in 1m ...

Страница 23: ...0002µbar Octave band limiting frequency Hz 0 10 20 30 40 50 60 70 80 CASSETTE TYPE AUU42R CASSETTE TYPE AUU42R 63 125 250 500 1 000 2 000 4 000 8 000 63 125 250 500 1 000 2 000 4 000 8 000 HIGH LOW HIGH LOW NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 NC 20 NC 40 NC 50 NC 60 NC 30 NC 15 NC 25 NC 35 NC 45 NC 55 NC 65 COOLING MODEL AUU42R HEATING MODEL AUU42R ...

Страница 24: ...CASSETTE TYPE AUU42R CASSETTE TYPE AUU42R 04 23 SOUND LEVEL CHECK POINT CENTER MIC 4ft 11 1 16in 1 5m CENTER MIC ...

Страница 25: ...g length ft Input kW Full Load Amp A Input kW Full Load Amp A 1 Wiring Spec Selected Sample Selected based on Japan Electrotechnical Standard and Codes Committee E0005 2 Limited Wiring length This is the wiring length in case voltage descent is less than 2 When the wiring length becomes long please select the wiring of a more larger diameter 60 AUU42R AOU42R 10 Rated Value Mode 1 Wiring Spec 15 30...

Страница 26: ... F 105 5 C COMPRESSOR PROTECTION THERMAL PROTECTOR OFF 257 F ON 176 F OFF 125 C ON 80 C HIGH PRESSURE PROTECTION PRESSURE SWITCH OFF 609 15 PSI ON 464 22 PSI OFF 4 2 0 1MPa ON 3 2 0 15MPa AOU42R 3 15A 250V FUSE ON MAIN PCB CURRENT FUSE 5A 250V PROTECTION FORM PCB FUSE CURRENT FUSE FAN MOTOR PROTECTION THERMAL PROTECTOR 302 9 F 105 5 C AUU42R 3 15A 250V ...

Страница 27: ...l circuit board SWITCH POSITION Auto restart validity invalidity Room temperature correct coefficient Room temperature correct coefficient Forbidden Indoor unit number setting Forbidden Forbidden Forbidden Ceiling height setting INDOOR UNIT DIP SW 3 1 JM3 Jumper Wire 2 3 JM1 JM2 Rotary SW SW 2 SW 1 SW 4 1 2 ...

Страница 28: ...ON Validity cooling SW 1 2 SW 1 3 heating dry ON ON ON OFF OFF OFF SW state OFF ON SW4 1 Dip SW 4 1setting forbidden Factory setting SW 4 1 OFF 0 degF 0 degF 0 degF 3 6degF 0 degF 3 6degF 3 6degF 3 6degF 3 6degF 3 6degF 0 degF 7 2degF If the setting for a low ceiling is selected the capacity of the air conditioner decreases slightly SW4 2 4 3 Ceiling height setting Factory setting 3 OFF ON Normal ...

Страница 29: ...when group control system Set the indoor unit address in the 0 1 15 order ROTARY SWITCH SETTING SW2 Factory setting 0 Single 1 15 Indoor unit address SW 2 SW state JUMPER WIRE SETTING Factory setting SW state JM 1 2 3 Connect Disconnect Forbidden JM 1 2 3 setting forbidden ...

Страница 30: ...NTROLLER CIRCUIT BOARD Wired remote controller DIP SW Dual remote controller setting Group control setting Model setting Auto changeover setting 1 2 3 4 5 6 Memory backup setting SWITCH POSITION Wired remote controller DIP Switch Front case back side ON ON OFF 1 2 3 4 5 6 ...

Страница 31: ...ory setting Number of indoor unit One unit connection DIP SW No 3 ON Multiple unit connection OFF 1 3 Model setting The system type of the outdoor unit can be selected by setting up DIP switch No 4 as follows Factory setting Model Heat Pump model DIP SW No 4 ON Cooling only model OFF 1 4 Auto changeover setting Selecting auto changeover validity invalidity Factory setting Auto changeover Invalidit...

Страница 32: ...PE AUU42R 04 31 4 16 OPTIONAL PARTS The additional grille hides the gap between the ceiling hole and the outlet grille ADDITIONAL GRILLE UTG AGEA W Additional grille optional parts Additonal grille The ceiling hole Indoor Unit grille ...

Отзывы: