ELECTRIC CHARACTERISTICS
9.
Model name
AO
G12LALL AO
G14LALL AO
G18LALL AO
G24LALA
Power supply
Voltage
V
230 ~
Frequency
Hz
50
*1) Max operating current
A
10.0
12.5
13.5
Starting Current
A
5.1
6.1
7.4
9.9
*2) Wiring Spec.
Main Fuse (Circuit breaker)
Current
A
25
Power Cable
mm
2
4.0
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring Spec.:
Selected
Sample
(Selected based on Japan Electrotechnical Standards and Codes Committee E0005)
Содержание AU*G12LVLB