![Fujitsu AU*G12LVLB Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/fujitsu/au-g12lvlb/au-g12lvlb_design-and-technical-manual_2343752060.webp)
- (02 - 10) -
OU
TDOOR
UNIT
AO
G1
2
-2
4
L
A
L
OU
TDOOR
UNIT
AO
G1
2
-2
4
L
A
L
ADDITIONAL CHARGE CALCULATION
6.
MODEL
: AO
G12LALL
Refrigerant charge
MODEL
: AO
G14LALL, AO
G18LALL
Refrigerant charge
MODEL
: AO
G24LALA
Refrigerant charge
Refrigerant type
R410A
Refrigerant amount
g
1150
Total pipe length
m
15 or less
20
25 (MAX)
20g/m
Additional charge
g
0
100
200
Refrigerant type
R410A
Refrigerant amount
g
1250
Total pipe length
m
15 or less
20
25 (MAX)
20g/m
Additional charge
g
0
100
200
Refrigerant type
R410A
Refrigerant amount
g
1700
Total pipe length
m
15 or less
20
25
30 (MAX)
20g/m
Additional charge
g
0
100
200
300
Содержание AU*G12LVLB
Страница 2: ...DTR_AU047E_02 2013 02 28 1 INDOOR UNIT CASSETTE TYPE AU G12LVLB AU G14LVLB AU G18LVLB AU G24LVLA ...
Страница 35: ... 01 32 CASSETTE TYPE AU G12 24LVL CASSETTE TYPE AU G12 24LVL SOUND LEVEL CHECK POINT 8 2 Microphone Microphone ...
Страница 49: ...2 OUTDOOR UNIT SINGLE TYPE AO G12LALL AO G14LALL AO G18LALL AO G24LALA DTR_AO099E_02 2013 02 28 ...
Страница 55: ... 02 05 OUTDOOR UNIT AO G12 24LAL OUTDOOR UNIT AO G12 24LAL MODEL AO G24LALA ...
Страница 65: ... 02 15 OUTDOOR UNIT AO G12 24LAL OUTDOOR UNIT AO G12 24LAL SOUND LEVEL CHECK POINT 8 2 Airflow ...