10. TEST RUN
Check items
(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do air flow direction louvers operate normally?
(4) Is the drain normal?
(5) Do not have an abnormal noise and vibration during operation?
•
Do not operate the air conditioner in test run for a long time.
[Operation method]
•
For the operation method, refer to the operating manual.
•
The outdoor unit, may not operate, depending on the room temperature. In this case,
keep on pressing the “MANUAL AUTO” button of the indoor unit for more than 10
seconds. The OPERATION indicator lamp and TIMER indicator lamp will begin to flash
simultaneously during cooling test run.
Then, heating test run will begin in about 3 minutes when HEAT is selected by the
remote controller operation [reverse cycle model only].
(Please follow the operating manual for remote controller operation.)
•
To end test operation, press the remote controller “Start/Stop(
)” button.
(When the air conditioner is running by pressing the “TEST RUN“ button, the
OPERATION Lamp and TIMER Lamp will simultaneously flash slowly.)
11. REMOTE CONTROLLER INSTALLATION
Check that the indoor unit correctly receives the signal from the remote controller, then
install the remote controller holder.
CAUTION
Do not install the remote controller holder in the following conditions:
• Any places exposed in direct sunlight
• Positions affected by the heat from a stove or heater
11.1. Remote controller holder installation
•
Install the remote controller a maximum distance of 7 m from the remote control signal
receiver. After installing the remote controller, check that it operates correctly.
•
Install the remote controller holder to a wall, pillar, etc. with the tapping screw.
Remote controller
holder fixing
Remote controller
mounting
Remote controller
holder
Tapping
screw
(small)
(1) Set
Remote
controller
(2) Down
12. OPTIONAL KIT INSTALLATION
This air conditioner can be connected with the following optional kits.
• Wired remote controller
• Simple remote controller
• External connect kit
• External input and output PCB
9. FRONT PANEL REMOVAL AND INSTALLATION
Intake grill removal
Intake grill installation
b
a
Open the intake
grille. While gently
pressing the left
and right mounting
shafts of the intake
grille outward “a”,
remove the intake
grille in direction of
the arrow “b”.
c
While holding the
grille horizontal, set
the left and right
mounting shafts into
the pillow blocks at
the top of the panel
“c”.
To latch each shaft
properly, insert the
shaft until it snaps.
Press 4 places on
the intake grille to
close it completely.
9.1. Front panel removal
(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove 4 caps.
(3) Remove wire cover.
(4) Remove 10 screws.
Screws (Wire cover)
Screws (10 position)
Caps (4 position)
Wire cover
NOTE :
When replacing the front panel, do not scratch or damage the louver.
(5) The front panel is pulled to the front, raising the upper surface, then the front panel is
removed.
Front panel
9.2. Front panel installation
(1) First, fit the lower part of the front panel, and insert top and middle hooks. (3 top sides,
5 middles)
Front panel
Top hooks
(3 position)
Top holes (3 position)
Indoor unit
Middle hooks
(5 position)
Middle hooks
(5 position)
(2) Attach the 10 screws.
(3) Attach the wire cover.
(4) Attach the 4 caps.
(5) Attach the intake grille.
CAUTION
Install the front panel and intake grille securely. If installation is imperfect, the front
panel or intake grille may fall off and cause injury.
9387082050_IM.indb 7
12/10/2015 13:33:26
AMP Air Conditioning
www.ampair.co.uk | [email protected]