5.  SELECTING THE MOUNTING POSITION

Decide the mounting position with the customer as follows:

5.1. Indoor unit

(1)  Install the indoor unit level on a strong wall which is not subject to vibration.

(2)  The inlet and outlet ports should not be obstructed : the air should be able to blow all 

over the room.

(3)  Install the unit a dedicated electrical branch circuit.

(4)  Do not install the unit where it will be exposed to direct sunlight.

(5)  Install the unit where connection to the outdoor unit is easy.

(6)  Install the unit where the drain pipe can be easily installed.

(7)  Take servicing, etc. into consideration and leave the spaces shown in “6.1. Installation 

dimensions”. Also install the unit where the filter can be removed.

Correct initial installation location is important because it is difficult to move the unit after it 

is installed.

 WARNING

Install the indoor unit where is capable to support the weight of the unit. Secure the 

unit firmly so that the unit does not topple or fall.

 CAUTION

Do not install the unit in the following areas:

•  Area with high salt content, such as at the seaside. It will deteriorate metal parts, caus

-

ing the parts to fail or the unit to leak water.

•  Area filled with mineral oil or containing a large amount of splashed oil or steam, such 

as a kitchen. It will deteriorate plastic parts, causing the parts to fail or the unit to leak 

water. 

•  Area where is close to heat sources. 

•  Area that generates substances that adversely affect the equipment, such as sulfuric 

gas, chlorine gas, acid, or alkali. It will cause the copper pipes and brazed joints to cor

-

rode, which can cause refrigerant leakage.

•  Area that can cause combustible gas to leak, contains suspended carbon fibers or 

flammable dust, or volatile in flammables such as paint thinner or gasoline.

•  If gas leaks and settles around the unit, it can cause a fire.

•  Area where animals may urinate on the unit or ammonia may be generated.

•   Do not use the unit for special purposes, such as storing food, raising animals, grow

-

ing plants, or preserving precision devices or art objects. It can degrade the quality of 

the preserved or stored objects.

•  Install the unit where drainage does not cause any trouble.

•  Install the indoor unit, outdoor unit, power supply cable, transmission cable, and re

-

mote control cable at least 1 m away from a television or radio receivers. The purpose 

of this is to prevent TV reception interference or radio noise. 

(Even if they are installed more than 1 m apart, you could still receive noise under 

some signal conditions.)

•  If children under 10 years old may approach the unit, take preventive measures so that 

they cannot reach the unit.

•  Install the indoor unit on the wall where the height from the floor is more than 1.8 m.

6.  INSTALLATION WORK

 CAUTION

•  Do not hit or push the human sensor. This may lead to damage or malfunction.

•  Do not touch the human sensor. Any scratches or dirt may lead to incorrect detection.

•  Do not place large objects near the human sensor. Also keep heating units outside the 

sensor’s detection area.

Detection range of the human sensor is as follows.

Vertical angle 90° (Side view)

90°

50°

50°

7 m

7 m

Horizontal angle 100° (Top view)

6.1. Installation dimensions

(Wall cap)

1.5 m or over

60 mm or over**

80 mm or over*

Wall hook bracket

130 mm 

or over**

1.8 m or over

*  The distance between the wall hook 

bracket and the ceiling should be  

80 mm or more.

** The side next to the sidewall must 

follow the size indicated in figure.

Remote 

controller

Remote  

controller  

holder

Tapping screw 

(small)

6.2. Indoor unit piping direction

The piping can be connected in the 7 directions in the figure. When the piping is con

-

nected in direction (B), (C), (D) or (E), cut along the piping groove in the side of the front 

panel with a hacksaw.

 

 

 

 

 

 

 

(B)  Right 

outlet

(A)  Rear 

outlet

(C)  Bottom 

outlet

(D)  Left bottom 

outlet

(E)  Left 

outlet

(Rear)

(F)  Centre 

outlet

(G)  Left rear 

outlet

6.3. Cutting the hole in the wall for the connecting piping

(1)  Cut a 80 mm diameter hole in the wall at the position shown in the following.

(2)  Cut the hole so that the outside end is lower (5 to 10 mm) than the inside end.

(3)  Always align the center of the wall hole. If misaligned, water leakage will occur.

(4)  Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with 

vinyl tape, and stick the pipe through the hole.

(5)  For left piping and right piping, cut the hole a little lower so that drain water will flow 

freely.

Wall hook bracket

Centring marks

Lower

Lower

10 mm 

or more

80 mm hole

10 mm 

or more

80 mm hole

Fasten with vinyl tape

5~10 mm

Wall pipe

(Field supply)

Wall cap

(Field supply)

(Inside)

(Outside)

Wall

 WARNING

Always use the wall pipe. If the wall pipe is not used, the cable that is connected between 

the indoor unit and the outdoor unit may touch metal, and cause an electric discharge.

9387082050_IM.indb   3

12/10/2015   13:33:21

AMP Air Conditioning

www.ampair.co.uk | [email protected]

Содержание ASYG36LMTA

Страница 1: ... Leakage Circuit Breaker ELCB CAUTION This product is not explosion proof and therefore should not be installed in explosive atmosphere To avoid getting an electric shock never touch the electrical components soon after the power supply has been turned off After turning off the power always wait 5 min utes or more before you touch the electrical components This product contains no user serviceable...

Страница 2: ...r 1 Saddle 1 set Wall pipe 1 Drain hose 1 Decorative tape 1 Tapping screws 1 set Vinyl tape 1 Sealant 1 2 4 Optional parts Refer to each installation manual for the method of installing optional parts Parts name Model name Application Wired Remote Controller UTY RVN M For air conditioner operation Wired Remote Controller UTY RNR Z1 For air conditioner operation Wired Remote Controller UTY RLR For ...

Страница 3: ...The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 1 m apart you could still receive noise under some signal conditions If children under 10 years old may approach the unit take preventive measures so that they cannot reach the unit Install the indoor unit on the wall where the height from the floor is more than 1 8 m 6 INSTALLATION WORK...

Страница 4: ...xagonal wrench 4 mm at opposite side to insert the drain cap till the drain cap contacts the tip of the drain cock No gap Hexagonal wrench Drain cock Drain cap CAUTION Insert the drain hose and drain cap into the drain port making sure that it comes in contact with the back of the drain port and then mount it If the drain hose is not connected properly leaking will occur For left piping and left r...

Страница 5: ... using the specified tightening method Otherwise the flare nuts could break after a prolonged period causing refrigerant to leak and generate hazardous gas if the refrigerant comes into contact with a flame Connect the piping so that the control box cover can easily be removed for servicing when necessary In order to prevent water from leaking into the control box make sure that the piping is well...

Страница 6: ...tallation may cause a fire When fixing the connection cable with the cable clamp always fasten the cable at the plastic jacket portion but not at the insulator portion If the insulator is chafed electric leakage may occur Always connect the earth ground wire Improper earthing grounding work can cause electric shocks Do not use the earth ground screw for the indoor unit to the outdoor unit unless i...

Страница 7: ...der to a wall pillar etc with the tapping screw Remote controller holder fixing Remote controller mounting Remote controller holder Tapping screw small 1 Set Remote controller 2 Down 12 OPTIONAL KIT INSTALLATION This air conditioner can be connected with the following optional kits Wired remote controller Simple remote controller External connect kit External input and output PCB 9 FRONT PANEL REM...

Страница 8: ...umber selection 3 Press the TEMP buttons to select the set ting value Press the 10 C HEAT button to switch between the left and right digits 4 Press the MODE button once to send the function set ting information Please confirm the beeping sound 5 Next please press Start Stop button once to fix the function setting Please confirm the beeping sound 6 Press the RESET button to cancel the function set...

Страница 9: ...n be selected Factory setting Setting Description Function Number Setting Value Operation Stop mode1 46 00 Setting forbidden 01 Forced stop mode 02 Operation Stop mode 2 03 Room temperature sensor switching Aux To use the temperature sensor on the wired remote controller only change the setting to Wired remote controller 01 This function will only work if the function setting 42 is set at Both 01 ...

Страница 10: ...uto switch error 4 1 Room temp sensor error 4 2 Indoor unit Heat Ex Middle temp sensor error 5 1 Indoor unit fan motor error 5 3 Drain pump error 5 7 Damper error 5 8 Intake grille error 5 15 Indoor unit error 6 2 Outdoor unit main PCB model information error or communication error 6 3 Inverter error 6 4 Active filter error PFC circuit error 6 5 Trip terminal L error 6 10 Display PCB microcomputer...