Program timer (combined use of the ON timer and the OFF timer)

You can set an integrated ON–OFF or OFF–ON timer as follows:

ON–OFF  Set the ON timer first. 

Then set the OFF timer by the air conditioner starts opera-

tion controlled with the ON timer earlier set.

OFF–ON  Set the OFF timer first. 

Then set the ON timer by the air conditioner stops opera-

tion controlled with the OFF timer earlier set.

The timer that is set later starts counting down after the counting 

down of the preceding timer is finished.

Note:

If you change the setting value for the timer after the program timer is 

set, the counting down of the timer will be reset at that moment.

11  SLEEP TIMER button

Each time you press the button, the time changes as follows:

1.0

2.0

3.0

5.0

7.0

CANCEL

hours

9.0

• Set the time while the 

 indicator on the remote controller display 

is blinking.

  To repeat the timer, press the button when the indicator is not 

displayed.

To help you to fall asleep comfortably and prevent excessive warming 

or cooling in sleep, the SLEEP timer controls the temperature setting 

automatically in accordance with the set time shown as follows. The 

air conditioner completely turns off after the set time has elapsed.

In HEAT mode

In COOL or DRY mode

Set 

temperature

30 min.

1 hour

1 hour

1.5 hour

Set time

Set time

Note for TIMER settings:

Any interruption of the power supply, such as a blackout or cutting off 

of a circuit breaker, makes the set internal clock go wrong. In such a 

case, the TIMER indicator on the indoor unit blinks, and you need to 

readjust the setting.

12  TEST RUN button

Only used for the initial test in the unit installation. 

Do not press this button under normal use because it will cause 

incorrect operation.

• During the test run, the OPERATION indicator and  the TIMER 

indicator blink simultaneously.

• To quit the test run that is started unintentionally, you need to turn 

off the air conditioner by pressing the START/STOP button.

13  ECONOMY button

Starts or stops ECONOMY operation that saves more electricity 

consumption than the other operations with a conservative adjustment 

of the room temperature.

When you press the button, the ECONOMY indicator on the indoor 

unit turns on.

• In COOL mode, the room temperature will be adjusted at a few 

degree higher than the defined temperature. 

  In HEAT mode, the room temperature will be adjusted at a few 

degree lower than the defined temperature.

• Especially in COOL mode, you can have improved dehumidification 

without significantly lowering the room temperature.

Notes:

• In COOL or HEAT mode, the maximum output of this operation is 

approximately 70 % of usual air conditioning operation.

• This operation cannot be performed during temperature monitoring 

by AUTO mode.

14  POWERFUL button

Starts POWERFUL operation that enables quick cooling down or 

warming up of the room. 

When you press the button to start the POWERFUL operation, the 

indoor unit emits 3 short beeps.

POWERFUL operation is automatically turned off in the following 

situations:

• Adjusted room temperature reached to the defined temperature in 

temperature setting in COOL, DRY, or HEAT mode.

• 20 minutes have passed after finishing the POWERFUL operation 

mode setting.

It is not turned off automatically during setting of the POWERFUL 

operation.

Notes:

• The airflow direction and the fan speed are controlled automatically.

• This operation cannot be performed simultaneously with ECONOMY 

operation.

To return to normal operation, press the button again. Then the indoor 

unit emits 2 short beeps.

15  Remote controller display

In this section, all the possible indicators are displayed for description.  

In actual operation, the display is linked with the button operation, and 

only shows the necessary indicators for each setting.

16  Signal transmitter

Aim to signal receiver of the indoor unit properly.

• Signal transmit indicator   on the remote controller display shows 

that signal from the remote controller is being transmitted.

• Operating range is approximately 7 m.

• You will hear a beep if the transmitted signal has been sent properly.  

If there is no beep, press the button on the remote controller again.

Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost 

may form on the outdoor unit during the heating operation, and 

it could reduce the operating performance of the product. 

For frost protection, a microcomputer-controlled automatic 

defrost function is equipped in this air conditioner. 

If frost forms, the air conditioner will temporarily stop, and 

defrost circuit will operate briefly (maximum of 15 minutes.)

OPERATION indicator on the indoor unit blinks during this 

operation. 

If frost forms on the outdoor unit after the heating operation, the 

outdoor unit will stop automatically after it operates for a few 

minutes. Then the automatic defrosting operation starts.

Auto-restart function

In event of power interruption such as a blackout, the air 

conditioner stops once. But it restarts automatically and 

performs previous operation when the power supply is resumed.

If any power interruption occurs after the timer is set, counting 

down of the timer will be reset. 

After the power supply is resumed, the TIMER indicator on the 

indoor unit blinks to notify you that there has been a timer fault. 

In such a case, reset the timer for your opportune time.

Malfunctions caused by other electrical devices:

Use of other electrical appliances such as an electric shaver or 

nearby use of a wireless radio transmitter may cause the malfunction 

of the air conditioner. 

If you encounter such a malfunction, turn off the circuit breaker once. 

Then turn it on again, and resume operation by using the remote 

controller.

Remote Controller Overview and Operations

Содержание asyg35llcr

Страница 1: ...uring thunderstorm Do not install the unit in area filled with mineral oil such as a factory or area containing a large amount of splashed oil or steam such as a kitchen Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use inflammable gases near the unit Do not expose yourself directly to the cooling ai...

Страница 2: ...ntrol signal receiver CAUTION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal may not be transmitted properly In such a case consult the store that you purchased ...

Страница 3: ...ture Temperature setting range AUTO 18 30 C COOL DRY 18 30 C HEAT 16 30 C Temperature control is not available in FAN mode 4 FAN button Controls the fan speed AUTO HIGH MED LOW QUIET When AUTO is selected the fan speed is automatically adjusted according to the operation mode 5 SET button Adjusts the vertical airflow direction 6 SWING button Starts or stops automatic swing of the vertical airflow ...

Страница 4: ...ton Starts POWERFUL operation that enables quick cooling down or warming up of the room When you press the button to start the POWERFUL operation the indoor unit emits 3 short beeps POWERFUL operation is automatically turned off in the following situations Adjusted room temperature reached to the defined temperature in temperature setting in COOL DRY or HEAT mode 20 minutes have passed after finis...

Страница 5: ...intake grille b b b a a 4 Press 4 places on the intake grille to close it completely Care and Cleaning Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the air fi...

Страница 6: ...nal parts of the unit In HEAT mode the outdoor unit stops and the indoor unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 4 In DRY mode the indoor unit operates at low fan speed to adjust the room...

Страница 7: ......

Страница 8: ......

Отзывы: