background image

En-8

Cleaning Ion deodorization filter and

 

Replacing Apple-catechin filter

1. 

Remove the air filters. Refer to steps 1 ~ 2

 

of “Cleaning air 

filter”.

2. 

Remove the air cleaning filters from the air cleaning filter 

holder.

Air cleaning filter

Air cleaning filter frame

3. 

Flush the Ion deodorization filter (light blue) with high-

pressure hot water until the surface of the filters are covered 

with water.

4. 

Wash the Ion deodorization filter with diluent neutral 

detergent.

Do not ream or rub, otherwise the deodorizing effect may decrease.

5. 

Rinse the Ion deodorization filter with water flow.

6. 

Dry the Ion deodorization filter in shade.

7. 

Remove the Apple-catechin filter (light green) from the air 

cleaning filter holder.

8. 

Set the new or washed air cleaning filters into the air 

cleaning filter frames.

NOTES: 

Use the Apple-catechin filter as soon as possible after opening 

the package. The air cleaning effect decreases when the filters 

are left in the opened package.

9. 

Install the air cleaning filter holders to the air filters.

Engage the 4 hooks at the rear of the air cleaning filter frame with 

the latch at both ends of the air filter.

 

* Take care that the air cleaning filter does not project beyond the 

frame.

Hook (4 places at the rear)

Latch (4 places)

NOTES: 

Take care that the air cleaning filter does not project 

beyond the frame.

10. 

Replace the air filters and close the intake grille. Refer to 

steps 4 ~ 5 of “Cleaning air filter”.

Replacing Ion deodorization filter

1. 

Remove the air filters. Refer to steps 1 ~ 2

 

of “Cleaning air 

filter”.

2. 

Remove the Ion deodorization filter (light blue) from the air 

cleaning filter holder.

3. 

Install the new Ion deodorizing filter.

Removing and installing intake grille

 

Removing intake grille

1.  Open the intake grille until it snaps.

2.  Pull the mounting shafts while keeping the intake grille in a 

horizontal position.

 

Installing intake grille

1.  While holding the intake grille horizontal, set the left and 

right mounting shafts into the pillow blocks at the top of the 
front panel. 
Insert the shaft until it snaps to latch each shaft properly.

2.  Close the intake grille.

3. 

Press 4 places on the intake grille to close it completely.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 

Fan mode operation for half a day to dry the internal parts thoroughly 
before the normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the performance even if you have maintained the unit properly.

In such a case, a product inspection is recommended.

For more information, consult authorized service personnel.

Filter indicator reset (Special setting)

This function can be used if set correctly during installation. Please 
consult authorized service personnel in order to use this function.

)

)

Clean the air filter when the indicator lamp show the 

following:

Indicator lamp

Blinking pattern

 

 

Blinks 3 times, at intervals of 21 seconds

After cleaning, reset the filter indicator by pushing

 

 on the 

indoor unit for 2 seconds or less.

9387858020_OM.indb   8

2/8/2019   1:53:16 PM

Содержание ASYG07KMTB

Страница 1: ...montage mural Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di util...

Страница 2: ...nsult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air ...

Страница 3: ...rroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product...

Страница 4: ...er to page 6 Activates the 10 C Heat operation 3 1 Indoor unit Remote controller signal receiver Horizontal airflow direction louvers For Manual Auto operation and Filter indicator reset Refer to page 11 Rating label Drain hose Indicator lamps 2 Front panel Air filter Intake grille 1 Air cleaning filter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation...

Страница 5: ...Powerful operation Refer to page 6 Activates or deactivates the Powerful operation For Airflow settings Refer to page 5 Controls the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Sets the On...

Страница 6: ... displayed as follows Timer Indicator on the remote controller display On Off timer Off On timer NOTES You can set the Program timer only within a span of 24 hours If you set the Sleep timer after setting the Program timer the Program timer is canceled 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode change...

Страница 7: ...e Powerful operation When activated the indoor unit will emit 2 short beeps When deactivated the indoor unit will emit 1 short beep The Powerful operation will be turned off automatically in the following situations The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling Dry or Heating mode 20 minutes after the Powerful operation...

Страница 8: ...ilter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Air filters Indoor unit ...

Страница 9: ...dorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a horizontal position Inst...

Страница 10: ...IONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard and indicator on the indoor unit will blink Restricted functions for wireless remote controller When using together ...

Страница 11: ...n the heating apparatus or computers off or set the temperature lower Refer to page 5 Airflow is weak or stops Is the fan speed set to Quiet To change the fan speed refer to page 5 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the se...

Страница 12: ...test run Restricted function Slow Slow In multi connection Standby mode Check the set operation mode of the indoor units 9 Manual Auto operation and Filter indicator reset You can operate the air conditioner with on the indoor unit Status Time to keep pressing Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and less than...

Отзывы: