background image

En-5

5.  AIRFLOW SETTINGS

5.1.  Fan speed setting

)

)

 Press 

 to control the fan speed.

The fan speed changes as follows.

(Auto)

(High)

(Med)

(Low)

(Quiet)

When 

 is selected, the fan speed depends on the operating 

condition.

To increase the air cleaning effect, set the fan speed to High.

5.2.  Airflow direction setting

For details of the airflow ranges, refer to “Airflow direction 

range”.

 

Vertical airflow direction setting

)

)

Press 

 to adjust the vertical airflow direction.

 

Horizontal airflow direction setting

 

CAUTION

Before you adjust the horizontal airflow direction, make 

sure that the vertical airflow direction louver has been 

stopped completely.

)

)

Adjust two knobs by hand.

 

Swing operation setting

)

)

Press 

 to start/stop the Swing operation.

NOTES: The Swing operation may stop temporarily when the indoor 

unit fan is rotating at very low speed or is stopped.

6.  TIMER OPERATIONS

NOTES: When [ 

 ] indicator on the indoor unit blinks, set the clock 

and timer again. This blinking shows that the internal clock go 
wrong due to an interruption of the power supply. 

6.1.  On timer or Off timer

The On timer starts the operation at your desired time.
The Off timer stops the operation at your desired time.

1. 

When you use the On timer, press 

When you use the Off timer, press 

.

2.  Press 

(

)

 to set on time or off time.

Pressing the button: The time will change by +5/-5 minutes.
Pressing and holding down the button: The time will change by 

+10/-10 minutes.

•  To deactivate the On/Off timer, press 

 while 

 is shown 

on the remote controller display. 
The indicator will disappear.

NOTES:  If you set the Sleep timer after setting the On timer or Off 

timer, the On timer or Off timer is canceled.

6.2.  Program timer

The Program timer operates as the combination of the On timer and Off 
timer.

1. 

Set On timer and Off timer. (Refer to “6.1.  On timer or Off 

timer”). 
The timer setting changes to the Program timer 
automatically.

The timer whose setting time is closer to the current time works first.

The order of the timer operation is displayed as follows:

Timer

Indicator on the remote controller display

On→Off timer
Off→On timer

NOTES: 

●   You can set the Program timer only within a span of 24 hours.
●   If you set the Sleep timer after setting the Program timer, the 

Program timer is canceled.

4.  BASIC OPERATIONS

 

3 steps to start operation

1.  Press 

 to start or stop the operation.

2.  Press 

 to select the operation mode.

The operation mode changes as follows.

AUTO   

COOL  

DRY   

FAN   

HEAT

3.  Press 

 to set the desired temperature.

The temperature changes by 1 °C increments.

Temperature setting range

Auto/Cooling/Dry

18 - 30 °C

Heating

16 - 30 °C

NOTES:

•  In the Cooling or Dry mode, set the temperature lower than the 

current room temperature.

•  In the Cooling mode, the indoor unit fan may stop from time to time 

to perform Fan control for energy saving that enables power-saving 
operation by stopping the rotation of the indoor unit fan when the 
outdoor unit is stopped. 
In initial setting, this function is activated. 
To deactivate the function, consult the installer or authorized service 
personnel.

•  In the Heating mode,

 

- set the temperature higher than the current room temperature.

 

- at the beginning of the operation, the indoor unit fan rotates at very 

low speed for 3-5 minutes.

 

- the Automatic defrosting operation overrides the Heating operation 

when necessary.

•  In the Fan mode, temperature control is not available. 

 

Airflow direction range

Vertical airflow direction

1

2

3

4

5

6

Change by 

 

1

2

3

4

5

6

Swing operation by 

Cooling, Dry

1

4

Heating

3

6

Fan *

1

4

or 3

6

* The Swing operation range depends on the airflow direction set before 

the Swing operation.

NOTES:

• 

Do not adjust the airflow direction louvers by hand.

• 

In the Auto or Heating mode, the airflow direction stay position 1 for 

a while from the start of the operation.

• 

In the Cooling or Dry mode, position 1-3 is recommended to prevent 

condensation drips damaging your property. If position 4-6 keeps for 

30 minutes or more in these modes, the airflow direction changes to 

position 3 automatically.

•  When using the mobile app (optional wireless LAN control is 

necessary), the vertical airflow can be selected from 4 positions.

9387858020_OM.indb   5

2/8/2019   1:53:15 PM

Содержание ASYG07KMTB

Страница 1: ...montage mural Avant d utiliser ce produit veuillez lire attentivement ces instructions Conservez ce manuel pour référence future MANUAL DE FUNCIONAMIENTO ACONDICIONADOR DE AIRE Tipo montado en pared Antes de utilizar el producto lea estas instrucciones detenida mente y conserve este manual para consultarlo en el futuro MANUALE DI ISTRUZIONI CONDIZIONATORE D ARIA Tipo montato a parete Prima di util...

Страница 2: ...nsult authorized service personnel Take care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air ...

Страница 3: ...rroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this product...

Страница 4: ...er to page 6 Activates the 10 C Heat operation 3 1 Indoor unit Remote controller signal receiver Horizontal airflow direction louvers For Manual Auto operation and Filter indicator reset Refer to page 11 Rating label Drain hose Indicator lamps 2 Front panel Air filter Intake grille 1 Air cleaning filter Name Color Operation or condition Operation Green Normal operation Timer Orange Timer operation...

Страница 5: ...Powerful operation Refer to page 6 Activates or deactivates the Powerful operation For Airflow settings Refer to page 5 Controls the fan speed Sets the automatic Swing operation Controls the vertical airflow direction After replacing batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET For Timer operations Refer to page 5 Sets the On...

Страница 6: ... displayed as follows Timer Indicator on the remote controller display On Off timer Off On timer NOTES You can set the Program timer only within a span of 24 hours If you set the Sleep timer after setting the Program timer the Program timer is canceled 4 BASIC OPERATIONS 3 steps to start operation 1 Press to start or stop the operation 2 Press to select the operation mode The operation mode change...

Страница 7: ...e Powerful operation When activated the indoor unit will emit 2 short beeps When deactivated the indoor unit will emit 1 short beep The Powerful operation will be turned off automatically in the following situations The Powerful operation runs for a certain amount of time and the room temperature reaches the set temperature in the Cooling Dry or Heating mode 20 minutes after the Powerful operation...

Страница 8: ...ilter cleaning involves high place work please consult the authorized service personnel Do not touch the aluminum fins of heat exchanger built in the indoor unit to avoid personal injury when you maintain the unit Do not expose the indoor unit to liquid insecticides or hair sprays Do not stand on slippery uneven or unstable surfaces when you maintain the unit Intake grille Air filters Indoor unit ...

Страница 9: ...dorization filter 1 Remove the air filters Refer to steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter Removing and installing intake grille Removing intake grille 1 Open the intake grille until it snaps 2 Pull the mounting shafts while keeping the intake grille in a horizontal position Inst...

Страница 10: ...IONAL PARTS 12 1 Wired remote controller The optional wired remote controller can be used You can use wired and wireless remote controller together However some functions of the wireless remote controller are restricted If you set the restricted functions beeping sound will be heard and indicator on the indoor unit will blink Restricted functions for wireless remote controller When using together ...

Страница 11: ...n the heating apparatus or computers off or set the temperature lower Refer to page 5 Airflow is weak or stops Is the fan speed set to Quiet To change the fan speed refer to page 5 In the Heating mode Have you just started the operation In this case the fan rotates at very low speed temporarily to warm up the internal parts of the unit In the Heating mode Is the room temperature higher than the se...

Страница 12: ...test run Restricted function Slow Slow In multi connection Standby mode Check the set operation mode of the indoor units 9 Manual Auto operation and Filter indicator reset You can operate the air conditioner with on the indoor unit Status Time to keep pressing Mode or operation In operation More than 3 seconds Stop Stopping 2 seconds or less Filter indicator reset More than 3 seconds and less than...

Отзывы: