 3.2. Removing and replacing parts

 3.2.1. Intake grille removal and installation

 

Intake grille removal

(1)  Hold the intake grille with both hands at the side, then pull to the front until it becomes 

hooked.

(2)  Keeping the intake grille in a horizontal position, pull the mounting shaft on the left and 

right to release.

Intake grille

Mounting 
shaft

Mounting 

shaft

 

Intake grille installation

(1)  Attach the left and right mounting shaft in the direction of the arrow to the panel top 

bearing while supporting the intake grille horizontally. Press this until it clicks so that 
each shaft snaps into place.

Mounting shaft

Mounting 
shaft

Bearing

Bearing

(2)  Press and close the intake grille.

Press here

 3.2.2. Front panel / control cover removal and installation

* In this description, the intake grille and wire cover already has been removed.

When the wire cover A is removed, the wire cover B can be removed.

 

Front panel/control cover/under cover removal

(1)  

Remove the under covers. (Press down on the markings on the side, then slide down.)

(2)  

Remove the screw covers (2 places) on the bottom of the front panel, and then remove 
the screws (5 places).

(3)  

Push down on the markings (2 places) on top of the front panel to release the hooks 
(3 places), then pull the front panel towards you.

(4)  

Pinch the tab on the control cover to release the hook, then open.

Under covers

Screws (5 places)

Markings 
(triangle)

Markings (triangle)

 Screw covers

Under covers

Wire cover B

Wire 

cover A

Control cover

Hook (3 places)

Markings (triangle)

Markings (triangle)

Tab

 

Front panel/control cover/under cover installation

Refer to the previous 

fi

 gure.

* Be sure to replace the screws (5 places) and screw cover (2 places).

 CAUTION

Please take caution when removing or installing the front panel. If the front panel falls, 
there is a risk of injury.

3.2.3. Uninstalling the indoor unit

Remove the indoor unit from the wall hook bracket as follows.
(1)  

Remove the under covers. (Refer to “3.2.2. Front panel / control cover removal and 
installation”.)

(2)  

Insert your 

fi

 ngers in the opening shown in the 

fi

 gure.

 

While pushing down on the lower part of the opening, release the hooks (2 places).

(3)  

Pull the indoor unit towards you.

Markings (triangle)

Hooks (rear side)

3.3. Pipe installation

3.3.1. Indoor unit piping direction

The piping can be connected in the 6 directions indicated in the following.
When the piping is connected to direction (B), (C), (D) or (E), cut along the piping groove 
on the side of the under cover with a hacksaw.

 

 

(B)  Right 

outlet

(E)  Left 

outlet

(F)  Left rear 

outlet

(C)  Right bottom 

outlet

(A)  Right rear outlet

(D)  Left bottom 

outlet

(Rear)

3.3.2.

  

Cutting the hole in the wall for connecting the pipes

(1) Cut a 2-9/16 in (65 mm) diameter hole in the wall at the position shown in the 

following.

(2)  Cut the hole so that the outside end is lower ( 3/16 to 3/8 in [5 to 10 mm] ) than the 

inside end.

(3)  Always align the center of the wall hole. If misaligned, water leakage will occur.
(4)  Cut the wall pipe to match the wall thickness, stick it into the wall cap, fasten the cap with 

vinyl tape, and stick the pipe through the hole.

(5)  For the left piping and the right piping, cut the hole a little lower so that drain water 

will 

fl

 ow freely.

Unit: in (mm)

Wall hook bracket

Centering marks

2-9/16 
(65) hole

4-1/2 (115)

2-13/16 (72)

2-9/16 

(65) hole

* Locally purchased

Fasten with vinyl tape *

5~10 mm

Wall pipe *

Wall cap *

(Inside)

(Outside)

Wall

 WARNING

Always use the wall pipe. If the wall pipe is not used, the cable that is connected 
between the indoor unit and the outdoor unit may touch metal, and cause an electric 
discharge.

9387603187_IM.indb   4

9387603187_IM.indb   4

16-Feb-21   13:22:41

16-Feb-21   13:22:41

Содержание ASUG09LZBS

Страница 1: ... grounding can cause accidental injury or death Earth Ground the unit following local electrical codes Connect all wiring tightly Loose wiring may cause overheating at connection points and a possible fire hazard When Transporting Be careful when picking up and moving the indoor and outdoor units Get a partner to help and bend your knees when lifting to reduce strain on your back Sharp edges or th...

Страница 2: ...ventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools are special Refer to the following table Especially when replacing a conventional refrigerant R22 model with a new refriger ant R410A model always replace the conv...

Страница 3: ...l the unit where it will be exposed to direct sunlight 5 Install the unit where connection to the outdoor unit or branch box is easy 6 Install the unit where the drain pipe can be easily installed 7 Take servicing etc into consideration and leave the spaces shown in 3 1 1 Installation dimensions Also install the unit where the filter can be removed Correct initial installation location is importan...

Страница 4: ... places CAUTION Please take caution when removing or installing the front panel If the front panel falls there is a risk of injury 3 2 3 Uninstalling the indoor unit Remove the indoor unit from the wall hook bracket as follows 1 Remove the under covers Refer to 3 2 2 Front panel control cover removal and installation 2 Insert your fingers in the opening shown in the figure While pushing down on th...

Страница 5: ...at the projection at the end of the cap with pliers etc No gap Hexagonal wrench Drain cock Drain cap Removing the drain hose Remove the screw at the left of drain hose and pull out drain hose Installing the drain hose Vertically insert the drain hose toward the inside so that the drain fixture white can ac curately align with the screw hole around the drain cock After inserting and before replacin...

Страница 6: ...at its grip keeping it in the right angle with the pipe in order to tighten the flare nut correctly Tighten the flare nuts with a torque wrench using the specified tightening method Otherwise the flare nuts could break after a prolonged period causing refrigerant to leak and generate hazardous gas if the refrigerant comes into contact with a flame Connect the piping so that the control box cover c...

Страница 7: ...e matching custom code 1 Press START STOP until only the clock is dis played on the remote controller display 2 Press MODE for at least 5 seconds to display the cur rent custom code initially set to A 3 Press TEMP to change the custom code between A B C D Match the code on the display to the air conditioner custom code 4 Press MODE again to return to the clock display The custom code will be chang...

Страница 8: ...lock as shown in the figure Cable tie accessory for option Connector CN300 Connector CN301 Screw small accessory for option Wire with connector accessory for option Connector CN13 Cable clamp accessory for option Wired remote controller cable Screw large accessory for option Terminal block Tab 7 Replace the control cover front panel and Intake grille 5 FUNCTION SETTING Perform the Function setting...

Страница 9: ...wer saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation Factory setting Function number Setting value Setting description 49 00 Disable 01 Enable 02 Remote controller 00 When the outdoor unit is stopped the indoor unit fan operates continuously following the setting on the remote controller 01 When the outdoor unit is stopped the in...

Страница 10: ...operation of each button on the remote control unit normal 2 Does each lamp light normally 3 Do air flow direction louvers operate normally 4 Is the drain normal 5 Do not have an abnormal noise and vibration during operation Do not operate the air conditioner in test run for a long time Operation method Before starting the test run wait for 1 minute after connecting the power supply By the wireles...

Страница 11: ...troller error 4 1 41 Room temp sensor error 4 2 42 Indoor unit heat ex middle temp sensor error 4 4 44 Human sensor error 5 1 51 Indoor unit fan motor error 5 3 53 Drain pump error 5 4 54 Electric air cleaner reverse VDD error 5 5 55 Filter set error Error display Error code Description OPERATION lamp green TIMER lamp orange ECONOMY lamp green 5 7 57 Damper error 5 8 58 Intake grille error 5 9 59 ...

Страница 12: ...CONOMY lamp green 10 5 A5 Low pressure error 13 2 J2 Branch boxes error Flexible multi split type Display mode 0 5s ON 0 5s OFF 0 1s ON 0 1s OFF Number of flashing Error display on the indoor unit OPERATION indicator lamp green TIMER indicator lamp orange ECONOMY indicator lamp green ...

Отзывы: