Fujitsu ASG7MI-KG Скачать руководство пользователя страница 2

En-1

1.  SAFETY PRECAUTIONS

To prevent personal injury or property damage, read this section 

carefully before you use this product, and be sure to comply 

with the following safety precautions.

Incorrect operation due to failure to follow the instructions may 

cause harm or damage, the seriousness of which is classified 

as follows:

 WARNING

This mark warns of death or serious injury.

 CAUTION

This mark warns of injury or damage to property.

This mark denotes an action that is PROHIBITED.

This mark denotes an action that is COMPULSORY.

Explanation of symbols displayed on the indoor unit or outdoor unit.

WARNING

This symbol shows that this product uses a 

flammable refrigerant. If the refrigerant is leaked and 

exposed to an external ignition source, there is a risk 

of fire.

CAUTION

This symbol shows that the operating manual should 

be read carefully.

CAUTION

This symbol shows that a service personnel should 

be handling this equipment with reference to the 

installation manual.

CAUTION

This symbol shows that information is available such 

as the operating manual or installation manual.

 WARNING

•  The appliance shall be installed, operated and stored 

in a room with a floor area larger than X m².

Amount of refrigerant charge

M (kg)

Minimum room area

X (m

2

)

M ≤ 1.22 

-

1.22 < M ≤ 1.23 

1.45

1.23 < M ≤ 1.50 

2.15

1.50 < M ≤ 1.75 

2.92

1.75 < M ≤ 2.0 

3.82

2.0 < M ≤ 2.5 

5.96

2.5 < M ≤ 3.0 

8.59

3.0 < M ≤ 3.5 

11.68

3.5 < M ≤ 4.0 

15.26

(IEC 60335-2-40)

•  This product contains no user-serviceable parts. 

Always consult authorized service personnel for 

repairing, installation, and relocation of this product. 

Improper installation or handling will cause leakage, 

electric shock, or fire.

•  In the event of a malfunction such as burning smell, 

immediately stop operation of the air conditioner, and 

disconnect all the power supply by turning off the 

electrical breaker or disconnecting the power plug.

Then consult authorized service personnel.

•  Take care not to damage the power supply cable. 

If it is damaged, it should be replaced only by 

authorized service personnel in order to avoid a 

hazard.

•  In the event of refrigerant leakage, be sure to keep 

away from fire or any flammables, and consult 

authorized service personnel.

•  In the event of a thunder storm or any prior sign 

of a lightning strike, turn off the air conditioner via 

the remote controller, and refrain from touching the 

product or the power source to prevent any electrical 

hazards.

•  This product shall be stored in a room without 

continuously operating ignition sources (for example: 

open flames, an operating gas appliance or an 

operating electric heater).

•  This product shall be stored in a well-ventilated area.
•  Be aware that refrigerants may not contain an odour.
•  This product shall be stored so as to prevent 

mechanical damage from occurring.

•  Disposing of the product shall be done properly, in 

compliance with national or regional regulations.

•  During transportation or relocation of the indoor unit, 

pipes shall be covered with the wall hook bracket for 

protection. 

Do not move this product by holding the indoor unit pipes. 

(The stress applied to the pipe joints may cause the 

flammable gas to leak during operation).

Contents

1.  SAFETY PRECAUTIONS

 ..........................................

1

2. PREPARATION ......................................................... 2
3.  NAME OF PARTS ..................................................... 3

3.1.  Indoor unit

 ........................................................ 3

3.2.  Remote controller ............................................. 3

4.  BASIC OPERATIONS

 ............................................... 5

5.  AIRFLOW SETTINGS ............................................... 5

5.1.  Fan speed setting

 ............................................. 5

5.2.  Airflow direction setting

 .................................... 5

6.  TIMER OPERATIONS ............................................... 5

6.1.  Weekly timer

 ..................................................... 6

6.2.  On timer or Off timer

 ......................................... 6

6.3.  Program timer ................................................... 6

6.4.  Sleep timer 

 ...................................................... 6

7.  ENERGY SAVING OPERATIONS ............................ 7

7.1.  Economy operation

 .......................................... 7

7.2.  Human sensor for energy saving ..................... 7

7.3.  Fan control for energy saving ........................... 7

8.  OTHER OPERATIONS ............................................. 8

8.1.  Powerful operation

 ........................................... 8

8.2.  Outdoor Unit Low Noise operation ................... 8

8.3.  10 °C Heat operation

 ........................................ 8

9.  SETTINGS ON INSTALLATION ................................ 8

9.1.  Remote controller custom code setting

 ............ 8

10. CLEANING AND CARE

 ............................................. 8

11. GENERAL INFORMATION

 .....................................

10

12. OPTIONAL PARTS

 .................................................

11

12.1. Wired remote controller

 ..................................

11

12.2. Wireless LAN control

 ......................................

11

12.3. Multi-type air conditioner

 ................................

11

13. TROUBLESHOOTING

 ............................................

11

9387602050_OM.indb   1

05-Feb-19   18:16:59

Содержание ASG7MI-KG

Страница 1: ... εγχειρίδιο ώστε να μπορείτε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo mural Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Настенного типа Перед эксплуатацией устройства внимательно ознакомьтесь с данным руководством и сохраняйте его для использования в...

Страница 2: ...ke care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller...

Страница 3: ...urroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this produc...

Страница 4: ...perly If there is no beep press the button again For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For 10 C Heat operation Refer to page 8 Activates the 10 C Heat operation 3 NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit keep the signal receiver ...

Страница 5: ...batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Obstacles such as a curtain or wall between the...

Страница 6: ...on 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lower than the current room temperature In the Heating mode set the temperature higher t...

Страница 7: ...ed the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28...

Страница 8: ... C Heating Lower than the set temperature Max 4 C Auto Depending on the operating mode Cooling Heating Dry Detection range of Human sensor 90 6 m 6 m 50 50 Side view Top view NOTES Since Human sensor detects infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When...

Страница 9: ...arm enough this operation will not perform If the wired remote controller optional is connected this function is restricted 9 SETTINGS ON INSTALLATION 9 1 Remote controller custom code setting By setting custom code of indoor unit and remote controller you can specify the air conditioner which the remote controller controls When two or more air conditioners are in the room and you wish to operate ...

Страница 10: ...o steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter The frequency of the cleaning is as shown in the following table What to do Frequency Cleaning indoor unit body When you notice Cleaning air filter Every 2 weeks Cleaning Ion deodorization filter Every 3 months Replacing Apple catechin fil...

Страница 11: ...e of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the Heating operation the outdoor unit will stop auto...

Страница 12: ... instructed to do an operating mode that it cannot perform indicator on the indoor unit will flash 1 second on 1 sec ond off and the unit will go into the standby mode Heating mode and Cooling mode or Dry mode Heating mode and Fan mode Operation can be done in the following different operating modes Cooling mode and Dry mode Cooling mode and Fan mode Dry mode and Fan mode The operating mode Heatin...

Страница 13: ...or unit because of the Automatic defrosting operation Refer to page 10 Outdoor unit emits water In the Heating mode The outdoor unit may emit water gener ated by the Automatic defrosting operation Refer to page 10 The unit operates differently from the remote controller setting Are the batteries in the remote controller exhausted Replace the batteries Operation is delayed after restart Has the pow...

Отзывы: