Fujitsu ASG7MI-KG Скачать руководство пользователя страница 13

En-12

Airflow is weak or stops.

 

Is the fan speed set to Quiet?  

⇒ 

To change the fan speed, refer to 

page 5.

 

Has the Fan Control for Energy Saving set? In this case, the 

indoor unit fan may stop temporarily while the Cooling operation. 

⇒ 

To cancel the Fan control for energy saving, refer to 

page 7

.

 

<In the Heating mode> Have you just started the operation? 

 

In this case, the fan rotates at very low speed temporarily to warm 

up the internal parts of the unit.

 

<In the Heating mode> Is the room temperature higher than the 

set temperature?  

In this case, the outdoor unit stops and the indoor unit fan rotates 

at very low speed. 

 

<In the Heating mode> Is [ 

 ] indicator blinking?  

In this case, the Automatic defrosting operation is working. The in-

door unit stops for maximum of 15 minutes. (Refer to 

page 10

.)

 

<In the Dry mode> The indoor unit operates at low fan speed to 

adjust the room humidity, and may stop from time to time.

 

<In the Auto mode> While the monitoring operation, the fan 

rotates at very low speed.

Noise is heard.

 

Is the unit operating, or immediate after stopping operation? 

In this case, refrigerant flowing sound may be heard. It may be 

particularly noticeable for 2-3 minutes after starting operation.

 

Do you hear a slight squeaking sound during the operation?  

This sound is produced by the minute expansion and contraction 

of the front panel caused by temperature change.

 

<In the Heating mode> Do you hear a sizzling sound? 

 

This sound is produced by the Automatic defrosting operation. 

(Refer to 

page 10

.)

Smell coming from the unit.

 

The air conditioner may absorb various smells generated from 

interior textile, furniture, or cigarette smoke. These smells may be 

emitted during the operation.

Mist or steam is emitted from the unit.

 

<In the Cooling or Dry mode> A thin mist may be generated by 

condensation formed with sudden cooling process.

 

<In the Heating mode> Is [ 

 ] indicator on the indoor unit blinking?  

In this case, steam may rise from the outdoor unit because of the 

Automatic defrosting operation.(Refer to 

page 10

.)

Outdoor unit emits water.

 

<In the Heating mode> The outdoor unit may emit water gener

-

ated by the Automatic defrosting operation. (Refer to 

page 10

.)

The unit operates differently from the remote controller setting.

 

Are the batteries in the remote controller exhausted? 

 Replace the batteries.

Operation is delayed after restart.

 

Has the power supply turned from Off to On suddenly? 

 

In this case,  the compressor will not operate for about 3 minutes 

to prevent a blowout of the fuse.

Immediately stop operation and turn off the electrical breaker in 

following cases. Then consult authorized service personnel.

•  The problem persists even if you perform these checks or 

diagnostics.

•  On the indoor unit, [  ] and [   ] blink while [   ] is blinking fast.

NOTES: 

For any troubleshooting related to the W-LAN control, refer 

to the setting manual for W-LAN adapter or the mobile app 

installed in your smartphone or tablet PC.

 

State of indicator lamps

Lighting pattern: 

 Off,   

 On,   

 Blinking,   

 Any state

State

Causes and solutions

See

page

Automatic defrosting operation

 

Please wait until finishing the defrosting 

(maximum of 15 minutes).

10

Filter indicator

 

Clean the air filter and reset the filter 

sign.

10

Error code display

 Consult authorized service personnel.

-

Timer setting error because of Auto restart

 Reset the clock and timer settings.

-

Test run operation (for authorized 

personnel only)

 Press   to quit the test run.

-

Restricted function

11

(Slow)

(Slow)

(In multi connection) Standby mode 

 Check the set operation mode of the 

indoor units.

11

 

Manual Auto operation and Filter indicator 

reset

You can operate the air conditioner with 

 on the 

indoor unit.

Status

Time to keep pressing

Mode or operation

In operation More than 3 seconds

Stop

Stopping

2 seconds or less

Filter indicator reset

More than 3 seconds and 

less than 10 seconds

Auto 

*1)

More than 10 seconds

(Only for servicing.

*2)

)

Forced cooling

*1)   In multi connection, the operation mode follows the other indoor 

units.

*2)   To stop the forced cooling, press this button or

 

 

on the remote 

controller.

(3 times)

(Fast)

9387602050_OM.indb   12

05-Feb-19   18:17:09

Содержание ASG7MI-KG

Страница 1: ... εγχειρίδιο ώστε να μπορείτε να ανατρέχετε σε αυτό στο μέλλον MANUAL DE FUNCIONAMENTO AR CONDICIONADO Tipo mural Antes de utilizar este produto leia atentamente estas instruções e guarde este manual para referência futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ КОНДИЦИОНЕР ВОЗДУХА Настенного типа Перед эксплуатацией устройства внимательно ознакомьтесь с данным руководством и сохраняйте его для использования в...

Страница 2: ...ke care not to damage the power supply cable If it is damaged it should be replaced only by authorized service personnel in order to avoid a hazard In the event of refrigerant leakage be sure to keep away from fire or any flammables and consult authorized service personnel In the event of a thunder storm or any prior sign of a lightning strike turn off the air conditioner via the remote controller...

Страница 3: ...urroundings of the outdoor unit clean and tidy and do not place items around it Any objects blocking or entering from the outlet ports may cause product malfunction Do not direct the airflow at fireplaces or heating apparatus Do not block or cover the intake grille and the outlet port Do not apply any heavy pressure to radiator fins Do not climb on place objects on or hang objects from this produc...

Страница 4: ...perly If there is no beep press the button again For Basic operations Refer to page 5 Starts or stops the air conditioner operation Changes the operation mode Adjusts the setting temperature For 10 C Heat operation Refer to page 8 Activates the 10 C Heat operation 3 NAME OF PARTS CAUTION For appropriate signal transmission between the remote controller and the indoor unit keep the signal receiver ...

Страница 5: ...batteries Press this button as shown in the following figure Use a tip of a ballpoint pen or other small object RESET CAUTION To prevent malfunction or damage of the remote controller Place remote controller at where will not be exposed to direct sunlight or excessive heat Remove batteries if the product is not going to be used for an extended period Obstacles such as a curtain or wall between the...

Страница 6: ...on 2 Press to select the operation mode The operation mode changes as follows AUTO COOL DRY FAN HEAT 3 Press to set the desired temperature The temperature changes by 0 5 C increments Temperature setting range Auto Cooling Dry 18 0 30 0 C Heating 16 0 30 0 C NOTES In the Cooling or Dry mode set the temperature lower than the current room temperature In the Heating mode set the temperature higher t...

Страница 7: ...ed the Weekly timer will be deactivated In such a case activate the Weekly timer after the other timer finishes If the wired remote controller optional is connected this function is restricted Day of the week Program number Without a timer On timer Off timer Examples of Weekly timer Example 1 7 00 9 00 11 00 17 00 23 00 Monday to Friday Program 1 Program 2 Program 3 Program 4 On Off On Off 26 C 28...

Страница 8: ... C Heating Lower than the set temperature Max 4 C Auto Depending on the operating mode Cooling Heating Dry Detection range of Human sensor 90 6 m 6 m 50 50 Side view Top view NOTES Since Human sensor detects infrared light given out by people the detection may be incorrect in the following situations Situations in which the sensor may detect no one in the room even when there is someone there When...

Страница 9: ...arm enough this operation will not perform If the wired remote controller optional is connected this function is restricted 9 SETTINGS ON INSTALLATION 9 1 Remote controller custom code setting By setting custom code of indoor unit and remote controller you can specify the air conditioner which the remote controller controls When two or more air conditioners are in the room and you wish to operate ...

Страница 10: ...o steps 1 2 of Cleaning air filter 2 Remove the Ion deodorization filter light blue from the air cleaning filter holder 3 Install the new Ion deodorizing filter The frequency of the cleaning is as shown in the following table What to do Frequency Cleaning indoor unit body When you notice Cleaning air filter Every 2 weeks Cleaning Ion deodorization filter Every 3 months Replacing Apple catechin fil...

Страница 11: ...e of the product For frost protection a microcomputer controlled automatic defrost function is equipped in this air conditioner If frost forms the air conditioner will temporarily stop and defrost circuit will operate briefly maximum of 15 minutes indicator on the indoor unit blinks during this operation If frost forms on the outdoor unit after the Heating operation the outdoor unit will stop auto...

Страница 12: ... instructed to do an operating mode that it cannot perform indicator on the indoor unit will flash 1 second on 1 sec ond off and the unit will go into the standby mode Heating mode and Cooling mode or Dry mode Heating mode and Fan mode Operation can be done in the following different operating modes Cooling mode and Dry mode Cooling mode and Fan mode Dry mode and Fan mode The operating mode Heatin...

Страница 13: ...or unit because of the Automatic defrosting operation Refer to page 10 Outdoor unit emits water In the Heating mode The outdoor unit may emit water gener ated by the Automatic defrosting operation Refer to page 10 The unit operates differently from the remote controller setting Are the batteries in the remote controller exhausted Replace the batteries Operation is delayed after restart Has the pow...

Отзывы: