En-5

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to 

Heating and Cooling model (Reverse Cycle).

 WARNING

In the following events, immediately stop opera-

tion of the air conditioner, and disconnect all the 

power supply by turning off the electrical breaker 

or disconnecting the power plug. Then consult your 

dealer or authorized service personnel.

As long as the unit is connected to the power sup-

ply, it is not insulated from the power supply even if 

the unit is turned off.

•  Unit smells of something burning or emits smoke

•  Water leaks from the unit.

Before requesting service, perform the following checks:

NORMAL FUNCTION

Does not operate immediately

•  If the unit is stopped and then immediately started again, 

the compressor will not operate for about 3 minutes, in 

order to prevent fuse blowouts.

• 

Whenever the electrical breaker is turned off then on 

again, the protection circuit will operate for about 3 min-

utes, preventing unit operation during that period.

Noise is heard

•  During operation and immediately after stopping the unit, 

the sound of water flowing in the air conditioner’s piping 

may be heard. Also, noise may be particularly noticeable 

for about 2 to 3 minutes after starting operation (sound 

of coolant flowing).

* •  During Heating operation, a sizzling sound may be heard 

occasionally. This sound is produced by the Automatic 

defrosting operation.

Smells

•  Some smell may be emitted from the indoor unit. This 

smell is the result of room smells (furniture, tobacco, 

etc.) which have been taken into the air conditioner.

Mist or steam are emitted

•  During Cooling or Dry operation, a thin mist may be 

seen emitted from the indoor unit. This results from the 

sudden cooling of room air by the air emitted from the air 

conditioner, resulting in condensation and misting.

* •  During Heating operation, the outdoor unit’s fan may 

stop, and steam may be seen rising from the unit. This is 

due to the Automatic defrosting operation.

Humidity does not drop

In the case of Dry operation.

•  In some conditions of the room, the humidity does not 

drop.

•  In order to lower the humidity, set a lower room tempera-

ture.

Air flow is weak or stops

•  Indoor unit fan may start later than the outdoor unit fan, 

or it may stop when the outdoor unit fan is not operating. 

This is due to the Indoor unit fan control for energy sav-

ing operation.

•  To disable this function, refer to the operation manual of 

the remote controller. (This function cannot be disabled 

in Auto fan mode.)

* •  When Heating operation is started, fan speed is tempo-

rarily very low, to allow internal parts to warm up.

* •  During Heating operation, if the room temperature rises 

above the thermostat setting, the outdoor unit will stop, 

and the indoor unit will operate at very low fan speed. If 

you wish to warm the room further, set the thermostat to 

a higher setting.

* •  During Heating operation, the unit will temporarily stop 

operation (maximum of 15 minutes) as the Automatic 

defrosting mode operates. During the Automatic defrost-

ing operation, the defrost mode will be indicated.

<<See operating manual of Remote controller.>>

•  The fan may operate at very low speed during Dry op-

eration or when the unit is monitoring the room’s tem-

perature.

•  During Quiet operation, the fan will operate at very low 

speed.

•  In the monitor Auto operation, the fan will operate at very 

low speed.

Water is produced from the outdoor unit

* •  During Heating operation, water may be produced from 

the outdoor unit due to the Automatic defrosting opera-

tion.

CHECK ONCE MORE

Does not operate at all

• 

Has the circuit breaker been turned off?

• 

Has there been a power failure?

• 

Has a fuse blown out, or a circuit breaker been tripped?

• 

Is the timer operating?

Poor cooling (or heating*) performance

• 

Is the air filter dirty?

•  Are the air conditioner’s intake grille or outlet port 

blocked?

•  Did you adjust the room temperature settings (thermo-

stat) correctly?

• 

Is there a window or door open?

•  In the case of Cooling operation, is a window allowing 

bright sunlight to enter? (Close the curtains.)

•  In the case of Cooling operation, are there heating ap-

paratus and computers inside the room, or are there too 

many people in the room?

• 

Is the unit set for Quiet operation?

• 

Is the air conditioner in Economy mode?

If the problem persists after performing these checks, or 

if you notice burning smells, stop operation immediately, 

disconnect the power supply, and consult with authorized 

service personnel.

9381067206_OM_EN.indd   5

2018/12/19   9:18:57

Содержание ARU12RGLX

Страница 1: ...STE MANUAL PARA FUTURA REFERENCIA OPERATING MANUAL Duct type English MODE D EMPLOI Type conduit Français MANUAL DE FUNCIONAMIENTO Tipo ducto Español PART No 9381067206 AIR CONDITIONER ARU12RGLX ARU18RGLX ARU24RGLX ARU30RGLX ARU36RGLX ARU42RGLX ARU48RGLX 9381067206_OM_EN indd 1 2018 12 19 9 18 56 ...

Страница 2: ...ditioner Duct type Do not start or stop the operation of this product by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling air flow for many hours Do not insert your fingers or any other objects into the outlet port or inlet port Do not operate with wet hands CAUTION Provide occasional ventilation during use Always ope...

Страница 3: ...se refer to the Operating manual of the remote controller FEATURES AND FUNCTIONS INVERTER On start up the air conditioner will operate at maximum capacity to bring the room quickly down to desired tempera ture Once the temperature in the room begins to achieve the set temperature the air conditioner will reduce its capacity and energy usage to the minimum capacity and input ratings ECONOMY OPERATI...

Страница 4: ...uently changes the air conditioner will once again select the appropriate operation Heating Cooling to ad just the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation Heating Cooling Dry Fan OPERATING TIPS Instructions relating to heating are applicable only to Heating and Cooling model Reverse Cycle He...

Страница 5: ...ng If the room is not cooled or heated well during Economy operation select normal operation Fan speed Controls the fan speed AUTO HIGH QUIET MED LOW When AUTO is selected the fan speed is automatically ad justed according to the operation mode Heating The fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approache...

Страница 6: ...e Air flow is weak or stops Indoor unit fan may start later than the outdoor unit fan or it may stop when the outdoor unit fan is not operating This is due to the Indoor unit fan control for energy sav ing operation To disable this function refer to the operation manual of the remote controller This function cannot be disabled in Auto fan mode When Heating operation is started fan speed is tempo r...

Отзывы: