background image

En-4

Heat*

•  Use to warm your room.

•  When Heating mode is selected, the air conditioner will 

operate at very low fan speed for about 3 to 5 minutes, 

after which it will switch to the selected fan setting. This 

period of time is provided to allow the indoor unit to warm 

up before beginning full operation.

•  When the room temperature is very low, frost may form 

on the outdoor unit, and its performance may be re-

duced. In order to remove such frost, the unit will auto-

matically enter the defrost cycle from time to time. During 

Automatic defrosting operation, the Heating operation 

will be interrupted.

•  After the start of Heating operation, it takes sometime 

before the room gets warmer.

Cool

  Use to cool your room.

Dry

•  Use for gently cooling while dehumidifying your room.

•  You cannot heat the room during Dry mode.

•  During Dry mode, the unit will operate at low speed; in 

order to adjust room humidity, the indoor unit’s fan may 

stop from time to time. Also, the fan may operate at very 

low speed when adjusting room humidity.

•  The fan speed cannot be changed manually when Dry 

mode has been selected.

Fan

  Use to circulate the air throughout your room.

 NOTES

*During Heating mode:

Set the thermostat to a temperature setting that is higher 

than the current room temperature. The Heating mode will 

not operate if the thermostat is set lower than the actual 

room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature setting that is lower than 

the current room temperature. The Cooling and Dry modes will 

not operate if the thermostat is set higher than the actual room 

temperature (in Cooling mode, the fan alone will operate).

During Fan mode:

You cannot use the unit to heat or cool your room.

Economy operation

At the maximum outlet, Economy operation is approximately 

70 % of normal air conditioner operation for cooling and 

heating.

If the room is not cooled (or heated), well during Economy 

operation, select normal operation.

Fan speed

Controls the fan speed.

AUTO

HIGH

QUIET

MED

LOW

When AUTO is selected, the fan speed is automatically ad-

justed according to the operation mode.

Heating*:   The fan will operate at very low speed when the 

temperature of the air issued from the indoor unit 

is low.

Cooling:   As the room temperature approaches that of the 

set temperature, the fan speed becomes slower.

Fan: 

 The fan runs at medium fan speed.

Auto restart

In Event of Power Interruption

•  Should the power supply to the air conditioner be inter-

rupted by a power failure, the air conditioner will restart 

automatically in the previously selected mode once the 

power is restored.

•  Use of other electrical appliances (electric shaver, etc.) or 

nearby use of a wireless radio transmitter may cause the 

air conditioner to malfunction. In this event, temporarily 

disconnect the power supply, reconnect it, and then use 

the remote controller to resume operation.

Multiple remote controller (optional)

An additional remote controller can be added up to the 

maximum of two remote controllers. Either remote controller 

can control the air conditioner. However, the timer functions 

cannot be used at the secondary unit.

Group control

One remote controller can control up to 16 air conditioners.

All of the air conditioners will be operated with the same settings.

Notices

*

•  During use of the Heating mode, the outdoor unit will 

occasionally commence the defrost operation for brief 

periods. During the defrosting operation, if the user sets 

the indoor unit for heating again, the defrosting mode 

will continue, and the Heating operation will begin after 

completion of defrosting, with the result that some time 

may be required before warm air is emitted.

*

•  During use of the Heating mode, the top of the indoor 

unit may become warm, but this is due to the fact that 

coolant is circulated through the indoor unit even when it 

is stopped; it is not a malfunction.

9381067206_OM_EN.indd   4

2018/12/19   9:18:57

Содержание ARU12RGLX

Страница 1: ...STE MANUAL PARA FUTURA REFERENCIA OPERATING MANUAL Duct type English MODE D EMPLOI Type conduit Français MANUAL DE FUNCIONAMIENTO Tipo ducto Español PART No 9381067206 AIR CONDITIONER ARU12RGLX ARU18RGLX ARU24RGLX ARU30RGLX ARU36RGLX ARU42RGLX ARU48RGLX 9381067206_OM_EN indd 1 2018 12 19 9 18 56 ...

Страница 2: ...ditioner Duct type Do not start or stop the operation of this product by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling air flow for many hours Do not insert your fingers or any other objects into the outlet port or inlet port Do not operate with wet hands CAUTION Provide occasional ventilation during use Always ope...

Страница 3: ...se refer to the Operating manual of the remote controller FEATURES AND FUNCTIONS INVERTER On start up the air conditioner will operate at maximum capacity to bring the room quickly down to desired tempera ture Once the temperature in the room begins to achieve the set temperature the air conditioner will reduce its capacity and energy usage to the minimum capacity and input ratings ECONOMY OPERATI...

Страница 4: ...uently changes the air conditioner will once again select the appropriate operation Heating Cooling to ad just the temperature to the value set in the thermostat If the mode automatically selected by the unit is not what you wish select one of the mode operation Heating Cooling Dry Fan OPERATING TIPS Instructions relating to heating are applicable only to Heating and Cooling model Reverse Cycle He...

Страница 5: ...ng If the room is not cooled or heated well during Economy operation select normal operation Fan speed Controls the fan speed AUTO HIGH QUIET MED LOW When AUTO is selected the fan speed is automatically ad justed according to the operation mode Heating The fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approache...

Страница 6: ...e Air flow is weak or stops Indoor unit fan may start later than the outdoor unit fan or it may stop when the outdoor unit fan is not operating This is due to the Indoor unit fan control for energy sav ing operation To disable this function refer to the operation manual of the remote controller This function cannot be disabled in Auto fan mode When Heating operation is started fan speed is tempo r...