14
Heating Performance*
M
This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
DVRXWGRRUDLUWHPSHUDWXUHGURSV,I\RXIHHOWKDWLQVXI¿FLHQW
heating performance is being produced, we recommend you
use this air conditioner in conjunction with another type of
heating appliance.
M
Heat-pump air conditioners heat your entire room by recircu-
lating air throughout the room, with the result that some time
PD\EHUHTXLUHGDIWHU¿UVWVWDUWLQJWKHDLUFRQGLWLRQHUXQWLOWKH
room is heated.
When Indoor and Outdoor Temperature
are High*
When both indoor and outdoor temperatures are high during use
of the heating mode, the outdoor unit’s fan may stop at times
to protect the unit.
Fan speed: AUTO
Heating*: The fan will operate at very low speed when the
temperature of the air issued from the indoor unit
is
low.
Cooling : As the room temperature approaches that of the set
temperature, the fan speed becomes slower.
Fan
: The fan runs at the low fan speed.
OPERATING TIPS
Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).
Microcomputer-controlled Automatic
Defrosting*
M
When using the heating mode under conditions of low out-
door temperature and high humidity, frost may form on the
outdoor unit, resulting in reduced operating performance.
,Q RUGHU WR SUHYHQW WKLV NLQG RI UHGXFHG SHUIRUPDQFH WKLV
unit is equipped with a microcomputer-controlled automatic
defrosting function. During the defrost cycle, the indoor fan will
shutdown and
will be displayed on the remote control-
OHU,WZLOOWDNHDQ\ZKHUHIURPWRPLQXWHVEHIRUHWKHDLU
conditioner starts up again.
M
After heating operation stops, if frost forms on the outdoor
unit, the unit will start automatic defrosting operation.
At this time, the outdoor unit will automatically stop after
operating for a few minutes.
Low Ambient Cooling
When the outdoor temperature drops, the outdoor unit’s fans may
switch to low speed, or one of the fans may stop intermittently.
Hot Start*
The indoor unit prevents cold drafts when heating operation
begins.
The indoor unit fan will not operate until the heat exchanger
reaches the set temperature.
Dual Remote Controllers (optional)
An additional remove controller can be added up to the maximum
of two remote controllers. Either remote controller can control
the air conditioner. However, the timer functions cannot be used
at the slave unit.
Group Control
1 remote controller can control up to 16 air conditioners. All of the
air conditioners will be operated with the same settings.