![background image](http://html.mh-extra.com/html/fujitsu/artc72latu/artc72latu_operating-manual_2344332009.webp)
En-8
2-1-2. Operation mode setting
In “Monitor” screen, select [Mode], and switch to the desired
operation mode with the [Cursor button (Up/Down)].
Mode
Menu
Auto
Monitor
Set temp.
Fan
High
°C
26
Mo 10:00
Operation mode marks
Auto
Cool
Dry
Fan
Heat
Note
Only the adjustable operation mode is displayed.
If there is another operation setting to be changed, you can
continue the configuration. Move to desired item by using
[Cursor button (Left/Right)].
2-1-3. Set temperature adjustment
In “Monitor” screen, select [Set temp.] with the [Cursor button
(Left/Right)], and adjust the room temperature with the [Cursor
button (Up/Down)].
Mode
Menu
Auto
Monitor
Set temp.
Fan
High
°C
26
Mo 10:00
Notes
• Possible temperature setting ranges in the operation
mode are as follows:
Cool, Dry, Auto ................
18 to 30 °C (64 to 88 °F)
Heat .................................
16 to 30 °C (60 to 88 °F)
• When operation mode is set to [Fan], the set
temperature cannot be adjusted. ([Set temp.] cannot
be selected.)
• If the temperature is being out of the range configured
in [Set temp. range] setting, message indicating
that the temperature is restricted is displayed on the
screen.
Menu
Restricted by the set temperature range restriction
11
2-1-4. Fan speed setting
In “Monitor” screen, select [Fan] with the [Cursor button
(Left/Right)], and adjust the fan speed with the [Cursor button
(Up/Down)].
Mode
Menu
Cool
Monitor
Set temp.
Fan
High
°C
26
Mo 10:00
Fan speed marks
Auto
High
Medium
Low
Note
When the operation mode is set to [Dry], Fan speed
switches to [Auto]. (Fan speed cannot be selected.)
About fan speed [Auto]
When the fan speed is set to [Auto], behavior of the indoor
unit fan in non-zone-controlled system and the one in zone-
controlled system is different as follows.
In non-zone-controlled system:
If the room temperature approaches to the configured
temperature in [Set temp.], the fan rotates with reduced
speed.
In zone-controlled system:
The fan speed is adjusted depending on the number of
air-conditioned zone(s).
If the volume of provided airflow by [Auto] is not agree-
able to your preference, adjust it to just the right fan
speed by changing the fan speed.