manualshive.com logo in svg
background image

AIR CONDITIONER

DUCT TYPE

Indoor Unit

ARTG30LHTA
ARTG36LHTA
ARTG45LHTA
ARTG60LHTA

ARTG36LHTB
ARTG45LHTB
ARTG54LHTB
ARTG60LHTB

ARTG54LHTC

ARTC72LATU
ARTC90LATU

OPERATING MANUAL

KEEP THIS MANUAL FOR FUTURE REFERENCE

FUJITSU GENERAL LIMITED

PART No. 9374379866

9374379866_OM_EN.indd   1

17/12/2014   13:19:23

Содержание ARTC72LATU

Страница 1: ...ndoor Unit ARTG30LHTA ARTG36LHTA ARTG45LHTA ARTG60LHTA ARTG36LHTB ARTG45LHTB ARTG54LHTB ARTG60LHTB ARTG54LHTC ARTC72LATU ARTC90LATU OPERATING MANUAL KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED PART No 9374379866 ...

Страница 2: ... timer setting 21 5 SUBMENU SETTING 23 5 1 Switching to the Submenu screen 23 5 2 Date Time setting 23 5 2 1 Date setting 23 5 2 2 Time setting 23 5 2 3 Summer time Daylight saving time setting 24 5 2 4 Change display format setting 24 5 3 Screen setting 25 5 3 1 Automatic off time setting 25 5 3 2 Brightness setting 25 5 3 3 Contrast setting 25 5 4 Filter sign setting 25 5 4 1 Filter sign reset s...

Страница 3: ... touch the fins of the heat exchanger built in this product to avoid personal injury when you install or maintain the unit Do not stand on unstable steps when operating or cleaning this product It may overturn and can cause the injury 1 1 INTRODUCTION 1 1 Safety precautions To prevent personal injury injury to others or property damage read this section carefully before you use this product and be...

Страница 4: ... the unit automatically switches to a low power setting for eco nomic and comfortable operation ECONOMY OPERATION When Economy operation mode is operated the room temperature will be a little higher than the set temp under Cooling mode and lower than set temp under Heating mode Therefore the Economy operation mode is able to save more energy than other normal modes AUTO CHANGEOVER The operation mo...

Страница 5: ...ops the operation 1 4 About Monitor screen Monitor screen shows several statuses such as the operat ing status of the air conditioner function setting or other cur rent operating conditions Mode Menu Cool Monitor Room 28 C Set temp Fan High C 26 Mo 10 00 Icon check 1 2 5 3 4 1 Screen status and current conditions Shows the current screen name room temperature day of the week and clock NOTES The cl...

Страница 6: ...reen switch guidance display Any combination of Menu button mark with name of switchable screen by pressing the Menu button or Screen switch button Left Right mark or with name of switchable screen by pressing the Screen switch button Left Right is displayed 1 5 About zone control Zone control enables an efficient air conditioning by select ing only specific zone from some divided zones in the ind...

Страница 7: ...nsor Indoor unit Zone group Mo 10 00 Monitor Off To cancel the air conditioning set the cursor to the zone marked with a check and press the Enter button to remove the check mark Unchecked zone is not air conditioned Note Depending on the initial setup in the installation there is a case that at least one zone need to be selected In that case following message is displayed on the screen and you ne...

Страница 8: ...ditioned Zone group Day Night All Sensor Zone Zone 1 Zone 2 Zone 3 Zone 4 Indoor Monitor Mo 10 00 Zone single Note The check mark currently displayed on the screen can be unchecked only if you mark a check to the other group on this screen or when any setting change is done in Zone single screen 2 BASIC OPERATIONS 2 1 Starting the operation PREPARATION Check whether the current time is displayed c...

Страница 9: ...ture is being out of the range configured in Set temp range setting message indicating that the temperature is restricted is displayed on the screen Menu Restricted by the set temperature range restriction 11 2 1 4 Fan speed setting In Monitor screen select Fan with the Cursor button Left Right and adjust the fan speed with the Cursor button Up Down Mode Menu Cool Monitor Set temp Fan High C 26 Mo...

Страница 10: ... range can be limited through the operation mode 13 Timer On timer Use this timer function to start air conditioner operation The timer operates and air condition operation starts after the set time has passed The timer can be set up to 24 hours in advance Can be set up to 24 hours in units of 30 minutes 14 Off timer Use this timer function to stop air conditioner operation The timer operates and ...

Страница 11: ...ontroller NOTE This setting can be set on either of one of the primary unit or the secondary unit 28 O Room temp temperature display Switches between displaying and non displaying the room temperature The displayed room temperature is the temperature around the remote control 28 O Key lock select Child lock Restricts all the button operation 28 O Part lock Restricts the Menu button operation 29 O ...

Страница 12: ...emp setting Time Temp Cool Dry 26 C 30min 26 C 30min Heat Mo 10 00 Setting Back Air flow dire Set temp range Select the item with the Cursor button Up Down and press the Enter button 3 FUNCTION SETTING 3 1 Switching to the Function screen 1 In Menu screen select Function with the Cursor button Up Down and press the Enter button Menu Function Timer Submenu Mo 10 00 Setting Back 2 Function screen is...

Страница 13: ...ter button to complete the setting Set temp auto return Enable Disable setting Enable Return time and temp setting Time Temp Cool Dry 26 C 30min 26 C 30min Heat Mo 10 00 OK Cancel Air flow dire Set temp range 4 For Return time and temp setting select operation mode with the Cursor button Up Down and press the Enter button Adjust the value with the Cursor but ton Up Down With the Cursor button Left...

Страница 14: ...en you return to the Monitor screen the icon is displayed To check the function press the Enter button and select the icon with the Cursor button Left Right Menu Cool Monitor Mo 10 00 High C 26 Set temp range End 4 TIMER SETTING 4 1 Switching to the Timer screen 1 In Menu screen select Timer with the Cursor button Up Down and press the Enter button Menu Function Timer Submenu Mo 10 00 Setting Back...

Страница 15: ...imer Off timer Weekly timer Auto off timer Disable Disable Disable Mo 10 00 Disable Setting Back 2 Off timer screen is displayed Off timer Enable Disable setting Time setting Disable 1 0 hour later Mo 10 00 On timer Weekly timer Setting Back To change the setting select the item with the Cursor button Up Down and press the Enter button 3 For Enable Disable setting select Enable or Disable with the...

Страница 16: ...kly timer select Day off Su Mo Tu Th Fr Sa We Weekly 1 Mo 10 00 Auto off timer Off timer OK Cancel Day off setting In Day off setting select the inapplicable days of the week if there are any days that you want to skip the weekly timer op eration 1 Select Day off with the Cursor button Up Down and press the Enter button Weekly timer Weekly timer setting Weekly timer select Day off Su Mo Tu Th Fr S...

Страница 17: ... We Weekly timer setting Time 5 8 Mo 10 00 Back Setting 2 Setting screen for the current day of the week opens 1 2 3 4 Weekly 1 Day Time End Su Mo Tu Fr Sa Th We Weekly timer setting Time 5 8 Mo 10 00 Cancel OK 3 Select applicable day of the week with the Cursor button Left Right and press the Cursor button Up Down Selected day of the week is highlighted 1 2 3 4 Weekly 1 Day Time End Su Mo Tu Fr S...

Страница 18: ...Notes When you set On timer you need to set both of the operating mode and the temperature firmly Without these configurations the timer will not work Possible temperature setting ranges in the operation mode are as follows Cool Dry Auto 18 to 30 C 64 to 88 F Heat 16 to 30 C 60 to 88 F If the temperature out of the Set temp range limitation is set it will be reset at the nearest temperature within...

Страница 19: ...10 00 Back Setting Weekly 1 Day Note Weekly timer setting screen consists maximum of 8 pages from Time 1 to Time 8 You can set one pat tern per page and maximum of 8 pattern per a day With pressing the Screen switch button Left Right during setting the screen switches to the previous page or the next page Example When the Screen switch button Right is pressed once on page Time 1 2 Weekly 1 Day Tim...

Страница 20: ...1 Weekly 1 Day Time End Su Mo Weekly timer setting Time 8 Time 2 Mo 10 00 Delete Push for two seconds OK Note To delete the setting move the cursor to the pattern number and press the Cancel button for 2 seconds 3 Adjust time setting of On Off timer with the Cursor but ton Up Down 1 Weekly 1 Day Time End Su Mo 5 00 Weekly timer setting Time 8 Time 2 Mo 10 00 Cancel OK 4 Select On On timer or Off O...

Страница 21: ...d 1 Weekly 1 Day Time End Su Mo 5 00 On Weekly timer setting Time 8 Time 2 Mo 10 00 Cancel OK Heat 20 C Zone single Sensor Secondary RC Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 After you select all the applicable zones press the Enter button to complete the individual setting of zone control Notes When you set On timer you need to set all of operating mode temperature room temperatu...

Страница 22: ...egistered will be sorted in time order Sorting function When you return to the Monitor screen the icon is displayed To check the function press the Enter button and select the icon with the Cursor button Left Right Cool Monitor High C 26 Menu Weekly timer Weekly 1 Mo 10 00 End Zone single 4 2 4 Auto off timer setting 1 In Timer screen select Auto off timer with the Cursor button Up Down and press ...

Страница 23: ... valid hour during the counting down the function works If the air conditioning operation is On by Weekly timer after counting down of Auto off timer has started the Auto off timer will not work When you return to the Monitor screen and current time is within the valid hour the icon is displayed as follows To check the function press the Enter button and select the icon with the Cursor button Left...

Страница 24: ...tes Display format of time depends on the setting Refer to 5 2 4 Change display format setting Even when summer time daylight saving time is applied set the standard time here Set On Off with 5 2 3 Summer time Daylight saving time setting 5 SUBMENU SETTING 5 1 Switching to the Submenu screen When Menu button is pressed twice while Monitor screen is displayed it switches to the Submenu screen If Me...

Страница 25: ...M PM To complete the setting press the Enter button The screen returns to the Date and Time screen 5 2 3 Summer time Daylight saving time setting Note Set only for users in an area where summer time daylight saving time is applicable 1 In Date and time screen select Summer time daylight saving time with the Cursor button Up Down and press the Enter button Date and time Date Su 31 03 2013 10 00 Tim...

Страница 26: ...nction can be used only if the setting is activated in the installation To activate this function consult authorized service personnel 5 3 Screen setting In Submenu screen select Screen with the Cursor button Up Down and press the Enter button Date and time Monitor Screen Filter sign R C sensor control Room temp display Off Off Mo 10 00 Setting Back Submenu 1 2 Screen screen is displayed Automatic...

Страница 27: ... sign Mo 10 00 End In Submenu screen select Filter sign with the Cursor but ton Up Down and press the Enter button Date and time Monitor Screen Filter sign R C sensor control Room temp display Off Off Mo 10 00 Setting Back Submenu 1 2 Filter sign screen is displayed Screen Display Filter sign reset Filter sign Initial Off Mo 10 00 Setting Back 5 4 1 Filter sign reset setting If filter sign icon is...

Страница 28: ...ck on the Monitor screen when operating To lock up When the Cancel button is pressed for about 3 seconds or more continuously on the Monitor screen To release the lock When the Cancel button is pressed for about 3 seconds or more continuously on the Monitor screen the lock is re leased and each applicable lock name on the screen turns off 5 5 R C sensor control setting Note This function can be us...

Страница 29: ...button The screen returns to the Initial screen and displays the selected language Language Italiano Español English Ελληνικά Português Русский Deutsch Français Türkçe Temp unit Cancel OK Mo 10 00 Following key lock functions are available Child lock Restricts all the button operation Part lock Restricts the Menu button operation When Child lock is set Mode Child lock Auto Monitor Set temp Fan Hig...

Страница 30: ... screen in following instruc tions Setting procedures are common to Day setting and Night setting Day setting Zone 1 Zone 3 Zone 5 Zone 7 Zone 4 Zone 2 Zone 6 Zone 8 Sensor Indoor unit Night setting Mo 10 00 Back Remove 5 8 2 Temperature unit setting 1 In Initial screen select Temp unit with the Cursor button Up Down and press the Enter button Initial Language English Temp unit Password setting Ma...

Страница 31: ...be registered in the group with the Cur sor button When you press the Enter button a check mark is displayed Day setting Zone 2 Zone 3 Zone 5 Zone 7 Zone 4 Zone 1 Zone 6 Zone 8 Sensor Indoor unit Night setting Mo 10 00 Remove Back To remove the check mark adjust the cursor to the zone name to be unchecked and press the Enter but ton again Note Depending on the initial setup in the installation not...

Страница 32: ...ld Name setting Zone 1 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 _ Back Space End Mo 10 00 Enter Cancel Preset names Lower case Text field Selecting zone to be named 1 In Zone user setting screen select Zone name setting with the Cursor button Up Down When you press the Enter button Name setting group screen is displayed As a setting example Zone 1 to 8 are supposed t...

Страница 33: ...hen there is an error on the indoor unit Code XXXXXX R C address 00 Error Mo 10 00 Monitor Address number of the relevant indoor unit Error code Lower case You can select and enter desired lower case In Lower case screen set the cursor to the target letter with the Cursor button and press the Enter button Selected letter is displayed in the text field Name setting Zone 1 a b c d e f g h i j k l m ...

Страница 34: ...peration is started fan speed is temporarily very low to allow internal parts to warm up During heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit will operate at very low fan speed If you wish to warm the room further set the thermostat to a higher setting During heating operation the unit will temporarily stop operation max...

Страница 35: ...ction setting been set to Enable or On On timer or Off timer does not work Has there been a power outage Any power outage cancels the On or Off timer After the power supply is resumed set the Enable Disable setting to Enable again 15 16 Weekly timer does not work Have all the necessary settings been completed in Weekly timer set ting 17 to 23 Operation is automati cally stopped Has off timer been ...

Страница 36: ...other wired remote controller when using 2 wired remote controllers Has Name setting been done on both wired remote controllers When using 2 wired remote controllers the name registration in Name setting need to be done on both wired remote controllers 32 NORMAL FUNCTION Volume of airflow changes Volume of the airflow is affected by configurations in the zone set ting If the airflow is too strong ...

Страница 37: ...n using the heating mode under conditions of low out door temperature and high humidity frost may form on the outdoor unit resulting in reduced operating performance In order to prevent this kind of reduced performance this unit is equipped with a microcomputer controlled automatic defrosting function During the defrost cycle the indoor fan will shutdown and will be displayed on the remote control...

Страница 38: ... operation first selected the fan will operate at low speed for about a few minute during which time the indoor unit detects the room conditions and selects the proper operation mode Room temperature is higher than the defined temperature in temperature setting Cooling mode or dry mode Room temperature is close to the defined temperature in temperature setting Determined by outdoor temperature Roo...

Страница 39: ...ation if the user sets the indoor unit for heating again the defrosting mode will continue and the heating operation will begin after completion of defrosting with the result that some time may be required before warm air is emitted Permissible ranges of temperature and humidity are as follows 8 4 Temperature and humidity range Cooling Dry operation Outdoor temperature About 5 C to 46 C Indoor tem...

Страница 40: ......

Отзывы: