En-19
10.2. Setting the dip switches
Set the remote controller DIP switches.
[Example]
ON
ON
OFF
1
2
3
4
5
6
DIP switch 1
Front case (back side)
(
★
Factory setting)
NO.
SW state
Detail
OFF
ON
DIP-
Switch 1
SW
1
★
Cannot be used.
(Do not change)
SW
2
★
Dual remote controller setting
* Refer to "DUAL REMOTE
CONTROLLERS" in "11.
SPECIAL INSTALLATION
METHODS".
SW
3
★
Use prohibited.
(Do not change)
SW
4
★
Use prohibited.
(Do not change)
SW
5
★
Use prohibited.
(Do not change)
SW
6
★
Invalidity Validity
Memory backup setting
* Set to ON to use batteries
for the memory backup. If
batteries are not used, all of
the settings stored in mem-
ory will be deleted if there is
a power failure.
10.3. Function setting
This procedure changes the function settings used to control
the indoor unit according to the installation conditions. Incor-
rect settings can cause the indoor unit to malfunction. This
procedure should be performed by authorized installation or
service personnel only.
Perform the Function Setting according to the installation con-
ditions using the remote controller. (Refer to the indoor unit
installation manual for details on the function numbers and
setting values.)
(1) Press the SET TEMP. buttons ( ) ( ) and FAN button
simultaneously for more than 5 seconds to enter the func-
tion setting mode.
SU MO TU WE TH FR SA
(2) Press the SET BACK button to select the indoor unit num-
ber.
SU MO TU WE TH FR SA
Unit number of INDOOR UNIT
SET BACK
(3) Press the Set time (
) buttons to select the function
number.
Function number
SU MO TU WE TH FR SA
(4) Press the SET TEMP. buttons ( ) ( ) to select the setting
value.
The display
fl
ashes as shown to the right during setting
value selection.
Setting value
SU MO TU WE TH FR SA
(5) Press the TIMER SET button to con
fi
rm the setting.
Press the TIMER SET button for a few seconds until the set-
ting value stops
fl
ashing.
If the setting value display changes or if “- -” is displayed
when the
fl
ashing stops, the setting value has not been set
correctly.
(An invalid setting value may have been selected for the
indoor unit.)
(6) Repeat steps 2 to 5 to perform additional settings.
Press the SET TEMP. buttons ( ) ( ) and FAN button
simultaneously again for more than 5 seconds to cancel the
function setting mode. In addition, the function setting mode
will be automatically canceled after 1 minute if no operation
is performed.
(7) After completing the FUNCTION SETTING, be sure to turn
off the power and turn it on again.
9374342419_02_IM.indb 19
9374342419_02_IM.indb 19
2015/6/25 10:27:16
2015/6/25 10:27:16