![Fujitsu AOYG18KLTA Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/fujitsu/aoyg18klta/aoyg18klta_design-and-technical-manual_2344271024.webp)
¢
Contents of function setting
Each function setting listed in this section is adjustable in accordance with the installation environ-
ment.
NOTE:
Setting will not be changed if invalid numbers or setting values are selected.
Function setting list
Function no.
Functions
1)
11
Filter sign
2)
30/31
Room temperature control for indoor unit sensor
3)
40
Auto restart
4)
44
Remote controller custom code
5)
49
Indoor unit fan control for energy saving for cooling
1) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the esti-
mated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number
Setting value
Setting description
Factory setting
11
00
Standard (400 hours)
01
Long interval (1,000 hours)
02
Short interval (200 hours)
03
No indication
♦
2) Room temperature control for indoor unit sensor
Depending on the installed environment, correction of the room temperature sensor may be re-
quired. Select the appropriate control setting according to the installed environment.
The temperature correction values show the difference from the Standard setting "00" (manufac-
turer’s recommended value).
Function number
Setting value
Setting description
Factory
setting
30
(For cooling)
31
(For heating)
00
Standard setting
♦
01
No correction 0.0 °C
02
-0.5 °C
More cooling
Less heating
03
-1.0 °C
04
-1.5 °C
05
-2.0 °C
06
-2.5 °C
07
-3.0 °C
08
-3.5 °C
09
-4.0 °C
10
+0.5 °C
Less cooling
More heating
11
+1.0 °C
12
+1.5 °C
13
+2.0 °C
14
+2.5 °C
15
+3.0 °C
16
+3.5 °C
17
+4.0 °C
DESIGN & TECHNICAL MANUAL
- 20 -
WALL MOUNTED
ASYG18, 24KLCA
Содержание AOYG18KLTA
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASYG18KLCA ASYG24KLCA ...
Страница 10: ...3 Wiring diagrams 3 1 Models ASYG18KLCA and ASYG24KLCA 6 WALL MOUNTED ASYG18 24KLCA ...
Страница 28: ... 24 WALL MOUNTED ASYG18 24KLCA ...
Страница 29: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOYG18KLTA AOYG24KLTA ...
Страница 38: ...5 Wiring diagrams 5 1 Model AOYG18KLTA 5 2 Model AOYG24KLTA 34 OUTDOOR UNIT AOYG18 24KLTA ...