High energy saving
High COP is realized by using Large heat exchanger, DC rotary compressor, and inverter
technology.
Energy saving control
Human sensor catches movements of people in a room, and operates with lower capacity when the room
is empty. When people come back to the room, it automatically returns to previous operating mode.
Energy saving operation by detecting someone’s movement
Human
sensor
10°C HEAT Operation
*Only available with Wireless RC.
The room temperature can be set to go no lower than 10°C,
thus ensuring that the room does not get too cold when not occupied
Caution)
When the room temperature is higher than 10°C, “
•
10°C HEAT
” operation does not start. Operation starts and maintains the room
temperature at 10°C when the temperature drops below 10°C.
When “
•
10°C HEAT
” operation stops, the room set temperature quickly returns to the preset temperature.
Outdoor unit low noise
*Only available with Wireless RC.
When air-conditioner operates in large capacity, operation noise of outdoor unit will be suppressed. In case
of room temperature being close to setting temperature, operation noise might not decrease.
Rated
noise level
3
dB
Down
Low noise
mode
Economy operation
Example : Cooling operation
5.0
4.0
3.0
2.0
1.0
0.0
H
e
a
ti
n
g e
ffi
c
ie
n
c
y (C
O
P
)
09
Class
12
Class
14
Class
4.85
4.40
3.91
4.27
4.12
LT series
LE series
14%up!
7%up!
10
°C
20
°C
“10°C HEAT”
Button
ON
Indoor unit
operation
START
Economy operation is energy saving, as the set
•
temperature of indoor unit is shifted by 1°C and
the maximum electric value of the outdoor unit is
suppressed.
T
emp.
Economy operation
Shift
setting
temp
Control maxmum current
Nomal operation
Time
Set temperature
Содержание AOYG09LTCN
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_01 2011 09 21 ...
Страница 11: ... 01 08 WALL MOUNTED TYPE AS G09 14LT WALL MOUNTED TYPE AS G09 14LT INSTALLATION PLACE Unit mm ...
Страница 23: ... 01 20 WALL MOUNTED TYPE AS G09 14LT WALL MOUNTED TYPE AS G09 14LT SOUND LEVEL CHECK POINT 8 2 ...
Страница 35: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LTCN AO G12LTCN AO G14LTCN DTR_AO092E_01 2011 09 21 ...
Страница 42: ... 02 06 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT WIRING DIAGRAMS 4 MODEL AO G09LT AO G12LT ...
Страница 43: ... 02 07 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT MODEL AO G14LT ...
Страница 51: ... 02 15 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT SOUND LEVEL CHECK POINT 8 2 ...