background image

En-2

OPERATING MANUAL

1 Intake 

grille

Before starting operation, make sure that the intake grille has been 
shut completely. Incomplete closing might have an effect on the 
proper working or performance of the product.

2  Manual AUTO button

Use when you lost the remote controller or remote control malfunction 
occurs.

Status

Action

Mode or operation

In operation

Press more than 3 seconds.

Stop

Stopping

Press more than 3 seconds and 

less than 10 seconds.

AUTO

Press more than 10 seconds.

(Only for servicing.*)

Forced cooling

After cleaning

Press less than 3 seconds.

Filter indicator reset

*:To stop forced cooling, press this button or “START/STOP” button 

on the remote controller.

3 Front 

panel

4 Vertical 

air

fl

 ow direction louver

Each time you press “SET” button on the remote controller, the angle 
of the vertical air

fl

 ow direction louver moves as follows:

1

2

3

7

6

5

*

*

4

COOL or DRY mode

HEAT mode

1

2

3

4

5

6 7

*: Default setting in each mode.

• Do not adjust by hand.
• At the beginning of AUTO or HEAT mode, they may stay position 1 

for a while for adjustment.

• If you set the angle to position 5–7 for more than 30 minutes in 

COOL or DRY mode, they automatically return to position 4.

  In COOL or DRY mode, if the angle is set to position 5–7 for many hours, 

condensation may be formed, and the drips may wet your property.

5 Drain 

hose

6  Remote control signal receiver

 CAUTION

For appropriate signal transmission between remote controller and 
the indoor unit, keep the signal receiver away from following items:

 

- Direct sunlight or other strong light

 

- Flat-panel television screen

In rooms with instantaneous 

fl

 uorescent lights, such as in-

verter type ones, the signal may not be transmitted properly. In 
such a case, consult the store that you purchased the product.

7  ECONOMY indicator (green)

Lights in ECONOMY operation.

8  TIMER indicator (orange)

Lights in TIMER operation, and blinks slowly when the timer setting 
error is detected.
As for the timer setting error, refer to “Auto-restart function” on page 4.

9  OPERATION indicator (green)

Lights in normal operation, and blinks slowly in automatic defrosting 
operation.

10  Horizontal air

fl

 ow direction louvers

 CAUTION

Before you adjust the horizontal air

fl

 ow direction, make sure that 

the vertical air

fl

 ow direction louver has been stopped completely.

Adjust two knobs by hand.

11

1

2

3

4

5

10

7

8

9

6

See page 5

11  Air 

fi

 lter

 Indoor unit accessories

Remote controller

Batteries

 WARNING

Take care to prevent infants and small children from acciden-
tally swallowing the batteries.

Battery (AAA/R03/LR03 × 2) loading

Notes:

• Use speci

fi

 ed type of battery only.

• Do not mix different types or new and used batteries together.
• Batteries can be used about 1 year in ordinary use.
• If the remote control range noticeably shortens, replace the 

batteries, and press “RESET” button.

1

2

3

Indoor Unit Overview and Operations

9332621006-04_OM.indb   2

9332621006-04_OM.indb   2

2016/3/29   11:41:23

2016/3/29   11:41:23

Содержание AOYG09LLCE

Страница 1: ...y with the appliance Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammable gases near this product Do not expose yourself directly to the cooling airflow for many hours Do not insert your fingers or any other objects into outlet port open panel or intake grille Do not operate with wet hands CAU...

Страница 2: ...TION For appropriate signal transmission between remote controller and the indoor unit keep the signal receiver away from following items Direct sunlight or other strong light Flat panel television screen In rooms with instantaneous fluorescent lights such as in verter type ones the signal may not be transmitted properly In such a case consult the store that you purchased the product 7 ECONOMY ind...

Страница 3: ...tting range AUTO 18 30 C COOL DRY 18 30 C HEAT 16 30 C Temperature control is not available in FAN mode 4 FAN button Controls the fan speed AUTO HIGH MED LOW QUIET When AUTO is selected the fan speed is automatically adjusted according to the operation mode 5 SET button Adjusts the vertical airflow direction 6 SWING button Starts or stops automatic swing of the vertical airflow direction louver Ea...

Страница 4: ...ables quick cooling down or warming up of the room When you press the button to start the POWERFUL operation the indoor unit emits 3 short beeps POWERFUL operation is automatically turned off in the following situations Adjusted room temperature reached to the defined temperature in temperature setting in COOL DRY or HEAT mode 20 minutes have passed after finishing the POWERFUL operation mode sett...

Страница 5: ...le b b b a a 4 Press 4 places on the intake grille to close it completely Care and Cleaning Cleaning the air filters Mind that you have a periodical cleaning of the air filters to prevent reducing the operation efficiency of the product Using of clogged air filter with dust will lower the product performance and may cause airflow reduction or increase of operating noise Clean the air filters once ...

Страница 6: ... unit In HEAT mode the outdoor unit stops and the indoor unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 4 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and ma...

Отзывы: