4-2. Model: AOYG14KETA
Strainer
Strainer
3-way
valve
2-way
valve
Muffler
4-way valve
Expansion valve
Heat exchanger
Heat exchanger
(INDOOR)
(OUTDOOR)
C
o
mp
re
sso
r
Cooling
Heating
Th
D
Th
R
Th
PI
Th
O
Th
HO
: Thermistor (Discharge temperature)
: Thermistor (Outdoor temperature)
: Thermistor (Heat exchanger out temperature)
Th
D
Th
O
Th
HO
: Thermistor (Room temperature)
: Thermistor (Pipe temperature)
Th
R
Th
PI
Muffler
- 51 -
4-2. Model: AOYG14KETA
4. Refrigerant circuit
OUTDOOR UNIT
AOYG07-14KETA
OUTDOOR UNIT
AOYG07-14KETA