PART NO. 9319205106

AIR CONDITIONER

English

Danish

Finnish

Norwegian,

INSTALLATION MANUAL

INSTALLATIONSVEJLEDNING

ASENNUSOHJE

INSTALLASJONSVEILEDNING

OUTDOOR UNIT (Split Type)

UDENDØRSENHED (split type)

ULKOYKSIKKÖ (jaettu)

UTENDØRSENHET (Delt utgave)

For authorized service personnel only.

Kun til autoriseret servicepersonale.

Vain valtuutetuille huoltohenkilöille.

Kun for autorisert servicepersonell.

Swedish

INSTALLATIONSHANDBOK

UTOMHUSENHET (Split-typ)

Endast för auktoriserad servicepersonal.

Polish

INSTRUKCJA MONTA

Ż

U

URZ

Ą

DZENIE ZEWN

Ę

TRZNE (typu split)

Do u

ż

ytku wy

łą

cznie przez autoryzowany personel obs

ł

ugi technicznej.

9319205106_IM.indb   1

9319205106_IM.indb   1

9/6/2011   10:14:12 AM

9/6/2011   10:14:12 AM

Содержание AOYG-09LTC

Страница 1: ...IKKÖ jaettu UTENDØRSENHET Delt utgave For authorized service personnel only Kun til autoriseret servicepersonale Vain valtuutetuille huoltohenkilöille Kun for autorisert servicepersonell Swedish INSTALLATIONSHANDBOK UTOMHUSENHET Split typ Endast för auktoriserad servicepersonal Polish INSTRUKCJA MONTAŻU URZĄDZENIE ZEWNĘTRZNE typu split Do użytku wyłącznie przez autoryzowany personel obsługi techni...

Страница 2: ...s for using R410A refrigerant The basic installation work procedures are the same as conventional refrigerant R22 models However pay careful attention to the following points Since the working pressure is 1 6 times higher than that of conventional refrigerant R22 models some of the piping and installation and service tools are special See the table below Especially when replacing a conventional re...

Страница 3: ...rts to fail or the unit to leak water Area filled with mineral oil or containing a large amount of splashed oil or steam It will deteriorate plastic parts causing the parts to fail or the unit to leak water Area that generates substances that adversely affect the equipment such as sulfuric gas chlorine gas acid or alkali It will cause the copper pipes and brazed joints to corrode which can cause r...

Страница 4: ...r cover 2 Bend the end of the cable as shown in the figure 3 Connect the end of the connection cable fully into the terminal block 4 Fasten the sheath with a cable clamp 5 Install the connector cover Cable clamp Connection cable N L 3 2 1 1 2 3 4 Outdoor unit terminal block Indoor unit terminal block Connection cable Earth screw Earth screw Power supply cable N L 3 2 1 25mm 12mm 5mm 5mm 12mm 20mm ...

Страница 5: ...lowly loosen the valve stem of the 3 way valve When the compound pressure gauge reading reaches 0 1 0 2 MPa retighten the valve stem and disconnect the charge hose from the 3 way valve charging port If the stem of the 3 way valve is opened fully before the charge hose is disconnect ed it may be difficult to disconnect the charge hose 10 Fully open the valve stems of the 2 way valve and 3 way valve...