ERROR CONTENTS
(indoor unit)
CAUTION
Supply power to the crankcase heater for at least
12 hours before the start of operation in winter.
(1) Stop the air conditioner operation.
(2) Press the master control button and the fan control button
simultaneously for 2 seconds or more to start the test run.
Test run display
(3) Press the start/stop button to stop the test run.
[SELF-DIAGNOSIS]
When the error indication "E:EE" is displayed, follow the follow-
ing items to perform the self-diagnosis. "E:EE" indicates an error
has occurred.
REMOTE CONTROLLER DISPLAY
(1) Stop the air conditioner operation.
(2) Press the set temperature buttons
simultaneously for 5
seconds or more to start the self-diagnosis.
Refer to the following tables for the description of each error
code.
SU MO TU WE TH FR SA
Unit number (usually 0)
Error code
(3) Press the set temperature buttons
simultaneously for 5
seconds or more to stop the self-diagnosis.
Error code
Error contents
Room temperature sensor open
Room temperature sensor short-circuited
Indoor heat exchanger temperature sensor open
Indoor heat exchanger temperature sensor
short-circuited
Outdoor heat exchanger temperature sensor
Power source connection error
Float switch operated
Outdoor temperature sensor
Discharge pipe temperature sensor
Outdoor high pressure abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal
Compressor temperature sensor
Pressure switch error
IPM error
CT error
Active filter module (AFM) error
Compressor does not operate
Outdoor unit fan error
Communication error
(inverter
multicontroller)
2 way valve sensor error
Expansion valve error
Connection indoor unit error
01
00
02
03
04
05
06
08
09
0A
0c
0E
11
12
13
14
15
16
17
18
19
1A
1b
1c
1d
1E
1F
Communication error
(Indoor unit
remote controller)
Communication error
(Indoor unit
outdoor unit)
2006.08.21
12
Содержание AOY30LNAWL
Страница 4: ... Unit mm OUTDOOR UNIT 77 900 830 21 9 400 330 31 12 196 147 170 99 370 650 Air Flow 2006 08 21 3 ...
Страница 16: ...56 55 108 41 150 67 138 164 INDOOR UNIT 2006 08 21 15 ...
Страница 17: ...816 817 287 236 553 288 287 875 INDOOR UNIT 2006 08 21 16 ...
Страница 18: ...6 11 7 5 2 4 3 1 OUTDOOR UNIT 2006 08 21 17 ...
Страница 19: ...9 8 10 13 15 OUTDOOR UNIT 2006 08 21 18 ...
Страница 20: ...24 21 27 25 12 28 17 18 26 20 19 29 23 22 26 OUTDOOR UNIT 2006 08 21 19 ...
Страница 26: ...0608G3120 ...