2
2003.11.26
HI-S PEED
(r.p.m.)
42 - 42
COOL 42 - 42 HEAT 42 - 42
INDOOR U NIT
M ED-S PEED (r.p.m.)
40 - 40
COOL 40 - 40 HEAT 40 - 40
LO-S PEED
(r.p.m.)
39 - 39
COOL 39 - 39 HEAT 34 - 34
S UPER QUIET (r.p.m.)
37 - 37
COOL 37 - 37 HEAT 32 - 32
OU TDOOR U NIT
(r.p.m.)
47 - 48
COOL 47 - 48 HEAT 49 - 49
N OIS E LE V E L
Note : Noise was measured in accordance with JIS standards, Japan.
B etween 7.5 m and 15 m, when using a connection pipe other than that in the table,
charge additional refrigerant with 20 g /1 m as the criteria.
A DDIT ION A L R E FR IG E R A N T CHA R G E
R efrigerant suitable for a piping length of 7.5 m is charged in the outdoor unit at the factory.
W hen the piping is longer than 7.5 m, additional charging is necessary.
For the additional amount, see the table below.
PIPE LENG TH
7.5 m
10 m
15 m
ADDITIONAL R EFR IG ER ANT
None
50 g
150 g
The maximum length of the piping is 15 m. If the units are further apart than this,
correct operation can not be guaranteed.