9
2003.11.26
Troubleshooting
When an error occurs, "Large division indication" is indicated first.
Secondly, "Small division indication" is indicated by pushing "Test" button of remote controller.
check table
Operation lamp
: Red lamp
Timer lamp
: Green lamp
Error contents
Error contents
thermistor error
RED lamp
(2 times) thermistor error (room temp.)
RED lamp
Green lamp
Green lamp
(2 times)
thermistor error (heat exchanger)
RED lamp
Green lamp
(3 times)
control unit error
RED lamp
(4 times) MANUAL AUTO button error
RED lamp
(indoor unit )
Green lamp
Green lamp
(2 times)
power source Hz decision error
RED lamp
Green lamp
(4 times)
fan motor error
RED lamp
(6 times) lock error
RED lamp
(indoor unit)
Green lamp
Green lamp
(2 times)
rpm error
RED lamp
Green lamp
(3 times)
: 0.5s ON/OFF repeated
: 0.1s ON/OFF repeated
LED indication
LED indication
Small division indication
Large division indication
ERROR DISPLAY