background image

9-4. Details of function

¢

Control input function

When function setting is “Operation/Stop” mode 1

– In the case of “Edge” input:

Function

setting

Rotary SW on External

input and output PCB

External input

Input signal

Command

46-00

1

External input and

output PCB

CN313

Off → On

Operation

On → Off

Stop

Operation

Stop

Remote controller

On

Off

Indoor unit

On

CN313

– In the case of “Pulse” input:

Function

setting

Rotary SW on External

input and output PCB

External input

Input signal

Command

46-00

1

External input and

output PCB

CN313

Pulse

Operation

CN314

Pulse

Stop

On

On

Off

Operation

Stop

Remote controller

On

Off

Indoor unit

CN313

CN314

NOTES:

• The last command has priority.
• The indoor units within the same remote controller group operates in the same mode.

- 25 -

9-4. Details of function

9. External input and output

WALL MOUNTED

ASUG09-15LZAS

WALL MOUNTED

ASUG09-15LZAS

Содержание AOUG09LZAS1

Страница 1: ...AIR CONDITIONER Wall mounted type DESIGN TECHNICAL MANUAL INDOOR ASUG09LZAS ASUG12LZAS ASUG15LZAS OUTDOOR AOUG09LZAS1 AOUG12LZAS1 AOUG15LZAS1 DR_AS116EF_02 2020 02 06 ...

Страница 2: ...please check with our authorized dealer Trademarks FGLair is trademark of Fujitsu General Limited in the United States other countries or both Google Play is trademark of Google Inc App Store is a service mark of Apple Inc registered in the U S and other countries Copyright 2019 Fujitsu General Limited All rights reserved ...

Страница 3: ...low 15 7 Operation noise sound pressure 18 7 1 Noise level curve 18 7 2 Sound level check point 19 8 Safety devices 20 9 External input and output 21 9 1 External input 22 9 2 External output 23 9 3 Combination of external input and output 24 9 4 Details of function 25 10 Remote controller 38 10 1 Wireless remote controller 38 11 Function settings 40 11 1 Function settings by using remote controll...

Страница 4: ... and AOUG15LZAS1 60 6 Capacity compensation rate for pipe length and height difference 61 6 1 Models AOUG09LZAS1 and AOUG12LZAS1 61 6 2 Model AOUG15LZAS1 62 7 Additional charge calculation 63 7 1 Models AOUG09LZAS1 and AOUG12LZAS1 63 7 2 Model AOUG15LZAS1 63 8 Airflow 64 8 1 Model AOUG09LZAS1 64 8 2 Model AOUG12LZAS1 64 8 3 Model AOUG15LZAS1 65 9 Operation noise sound pressure 66 9 1 Noise level c...

Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE ASUG09LZAS ASUG12LZAS ASUG15LZAS ...

Страница 6: ...Airflow rate Cooling HIGH CFM m3 h 542 920 542 920 583 990 MED 406 690 406 690 459 780 LOW 312 530 312 530 312 530 QUIET 206 350 206 350 241 410 Heating HIGH 542 920 542 920 600 1 020 MED 406 690 406 690 459 780 LOW 312 530 312 530 312 530 QUIET 206 350 206 350 241 410 Type Q ty Crossflow fan 1 Motor output W 59 Sound pressure level 3 Cooling HIGH dB A 43 43 45 MED 37 37 40 LOW 31 31 32 QUIET 23 2...

Страница 7: ... 8 33 CDB 15 FWB 9 44 CWB Pipe length 25 ft 7 5 m Height difference 0 ft 0 m Between outdoor unit and indoor unit Protective function might work when using it outside the operation range 2 Maximum current is maximum value when operated within the operation range 3 Sound pressure level Measured values in manufacturer s anechoic chamber Because of the surrounding sound environment the sound levels m...

Страница 8: ...eless router complies with the network security standards listed above refer to the operation manual Smartphone or Tablet PC App compliant operating system iOS Check the latest version of supported OS at Google Play store or App Store Android mobile application Mobile app is available on Google Play store or on App Store After installation of mobile app user registration is required For user regis...

Страница 9: ...2 1 POWERFUL operation setting 1 1 ECONOMY operation setting Additional function MIN HEAT operation setting 1 1 Room temperature indication Human sensor for energy saving setting 1 1 Outdoor unit low noise operation setting 1 1 App function Air conditioner error e mail notification 1 Not operable when wired remote controller is connected 2 Configurable functions of the weekly timer differs on wire...

Страница 10: ... of indoor unit 1 7 16 37 1 7 16 37 15 3 4 400 3 9 16 90 16 1 4 413 3 1 16 77 2 7 8 73 16 7 16 417 2 3 8 61 16 7 8 429 4 1 2 115 2 13 16 72 for pipe inlet Ø 2 9 16 65 for pipe inlet Ø 2 9 16 65 6 3 1 Models ASUG09LZAS ASUG12LZAS and ASUG15LZAS 3 Dimensions WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 11: ...y Unit in mm Wall hook bracket Outline of the indoor unit 2 50 or more 3 71 or more 2 40 or more 3 70 or more 5 117 or more 60 1 500 or more 71 1 800 or more 7 160 or more 7 3 1 Models ASUG09LZAS ASUG12LZAS and ASUG15LZAS 3 Dimensions WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 12: ...4 Wiring diagrams 4 1 Models ASUG09LZAS ASUG12LZAS and ASUG15LZAS 8 4 1 Models ASUG09LZAS ASUG12LZAS and ASUG15LZAS 4 Wiring diagrams WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 13: ...9 00 8 15 0 50 9 55 8 12 0 51 10 06 8 63 0 51 104 6 00 5 67 0 45 6 68 6 16 0 46 7 36 6 71 0 46 7 60 7 26 0 46 8 05 7 22 0 47 8 52 7 70 0 47 115 5 52 5 33 0 45 6 17 5 71 0 46 6 78 6 22 0 46 6 99 6 74 0 46 7 43 6 71 0 47 7 84 7 15 0 47 AFR m3 h 920 Indoor temperature CDB 17 8 21 1 23 9 26 7 29 4 32 2 CWB 12 2 15 6 17 2 19 4 21 7 22 8 Outdoor temperature CDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC...

Страница 14: ... 74 2 50 0 74 2 90 2 49 0 74 3 07 2 65 0 75 Model ASUG15LZAS AFR CFM 583 Indoor temperature FDB 64 70 75 80 85 90 FWB 54 60 63 67 71 73 Outdoor temperature FDB TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW 14 12 72 9 80 0 36 14 18 10 92 0 36 15 63 12 04 0 38 16 10 12 40 0 37 17 04 13 13 0 37 18 02 13 88 0 38 23 12 53 9 62 0 39 13 95 10 ...

Страница 15: ... 10 0 8 3 7 48 1 84 7 30 1 88 7 13 1 91 6 77 1 99 15 0 10 0 7 75 1 63 7 57 1 67 7 38 1 70 7 02 1 77 Model ASUG12LZAS AFR CFM 542 Indoor temperature FDB 60 65 70 75 Outdoor temperature FDB FWB TC IP TC IP TC IP TC IP kBtu h kW kBtu h kW kBtu h kW kBtu h kW 5 7 15 8 2 01 15 4 2 05 15 0 2 09 14 3 2 17 5 3 17 4 2 02 17 0 2 06 16 6 2 10 15 8 2 19 14 12 18 3 1 98 17 8 2 03 17 4 2 07 16 5 2 15 23 19 20 0...

Страница 16: ...23 6 2 13 59 50 27 2 1 75 26 5 1 79 25 9 1 82 24 6 1 89 AFR m3 h 1 020 Indoor temperature CDB 15 6 18 3 21 1 23 9 Outdoor temperature CDB CWB TC IP TC IP TC IP TC IP kW kW kW kW 20 6 21 7 5 73 2 63 5 60 2 69 5 46 2 74 5 19 2 85 15 0 16 1 6 46 2 64 6 31 2 70 6 15 2 75 5 84 2 86 10 0 11 1 6 65 2 53 6 49 2 58 6 33 2 63 6 02 2 74 5 0 7 2 6 84 2 41 6 68 2 46 6 52 2 51 6 19 2 61 0 0 2 2 7 04 2 30 6 87 2...

Страница 17: ...7 3 0 3 7 10 ft ft 0 3 7 10 13 16 20 23 26 3 2 1 0 1 2 3 Unit ft s m s m m 0 1 2 3 4 5 6 7 8 9 30 7 2 0 7 2 0 3 1 0 3 1 0 2 0 5 2 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 7 2 0 2 0 5 3 1 0 3 2 1 0 Unit ft s m s m m 0 1 2 3 4 5 6 7 8 10 7 3 0 ft ft 0 3 7 10 13 16 20 23 26 9 30 Side view Vertical airflow direction louver Down Horizontal airflow di...

Страница 18: ...6 20 23 26 3 2 1 0 1 2 3 Unit ft s m s m m 0 1 2 3 4 5 6 7 8 9 30 7 2 0 7 2 0 3 1 0 3 1 0 2 0 5 2 0 5 Side view Vertical airflow direction louver Up Horizontal airflow direction louver Center 7 2 0 2 0 5 3 1 0 3 2 1 0 Unit ft s m s m m 0 1 2 3 4 5 6 7 8 10 7 3 0 ft ft 0 3 7 10 13 16 20 23 26 9 30 Side view Vertical airflow direction louver Down Horizontal airflow direction louver Center 7 2 0 2 0 ...

Страница 19: ... 192 CFM 406 LOW m3 h 530 l s 147 CFM 312 QUIET m3 h 350 l s 97 CFM 206 Heating Fan speed Airflow HIGH m3 h 920 l s 256 CFM 542 MED m3 h 690 l s 192 CFM 406 LOW m3 h 530 l s 147 CFM 312 QUIET m3 h 350 l s 97 CFM 206 15 6 2 Airflow 6 Fan performance WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 20: ...CFM 406 LOW m3 h 530 l s 147 CFM 312 QUIET m3 h 350 l s 97 CFM 206 Heating Fan speed Airflow HIGH m3 h 920 l s 256 CFM 542 MED m3 h 690 l s 192 CFM 406 LOW m3 h 530 l s 147 CFM 312 QUIET m3 h 350 l s 97 CFM 206 16 6 2 Airflow 6 Fan performance WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 21: ...M 459 LOW m3 h 530 l s 147 CFM 312 QUIET m3 h 410 l s 114 CFM 241 Heating Fan speed Airflow HIGH m3 h 1 020 l s 283 CFM 600 MED m3 h 780 l s 217 CFM 459 LOW m3 h 530 l s 147 CFM 312 QUIET m3 h 410 l s 114 CFM 241 17 6 2 Airflow 6 Fan performance WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 22: ...000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Model ASUG15LZAS Cooling Octave band sound pressure level dB 0 dB 0 0002 µbar Octave band center frequency Hz 80 70 60 50 40 30 20 10 0 63 125 250 500 1 000 2 000 4 000 8 000 NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 HIGH QUIET Heating Octave band sound pressure level dB 0 dB 0 0002 µbar Octave...

Страница 23: ...1 m Microphone Microphone NOTE Detailed shape of the actual indoor unit might be slightly different from the one illustrated above 19 7 2 Sound level check point 7 Operation noise sound pressure WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 24: ...15LZAS Circuit protection Current fuse PCB 250 V 3 15 A Fan motor protection Thermal protector program Activate 257 18 F 125 10 C Fan motor stop Reset 212 18 F 100 10 C Fan motor restart PCB Printed Circuit Board 20 8 Safety devices WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 25: ...utput Connector Input select Input signal External input and output UTY XCSXZ2 Operation Stop CN313 CN314 Dry contact Apply voltage Edge Pulse Forced stop Forced thermostat off CN313 Edge Operation status CN310 Error status CN311 Indoor unit fan operation status CN312 External heater output 21 9 External input and output WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 26: ... the application Both types of connec tors cannot be used simultaneously Dry contact In case of internal power supply set the slide switch of SW301 to NON VOL side 1 2 3 Input 1 PCB Connected unit 1 2 3 Input 2 Connector CN313 Connector CN314 1 The switches can be used on the following condition DC 12 V to 24 V 1 mA to 15 mA Apply voltage In case of external power supply set the slide switch of SW...

Страница 27: ...on External input and output PCB is set to 1 1 2 Connector CN310 LED 1 Operation status PCB Resistor Connected unit 1 2 Connector CN311 LED 2 Error status Resistor 1 2 Connector CN312 LED 3 Indoor unit fan operation status Resistor When connecting with a device equipped with a power supply Example Rotary SW on External input and output PCB is set to 1 1 2 Connected device 1 Connector CN310 PCB Con...

Страница 28: ... CN312 1 Operation Stop Error status Indoor unit fan operation status 2 Error status Indoor unit fan operation status External heater output 3 9 A Setting prohibited B Operation Stop Indoor unit fan operation status External heater output C Operation Stop Error status External heater output D Operation Stop Indoor unit fan operation status Error status NOTE Input of Operation Stop depends on the s...

Страница 29: ...Off Indoor unit On CN313 In the case of Pulse input Function setting Rotary SW on External input and output PCB External input Input signal Command 46 00 1 External input and output PCB CN313 Pulse Operation CN314 Pulse Stop On On Off Operation Stop Remote controller On Off Indoor unit CN313 CN314 NOTES The last command has priority The indoor units within the same remote controller group operates...

Страница 30: ...and output PCB External input Input signal Command 46 02 1 External input and output PCB CN313 Pulse Forced stop CN314 Pulse Normal On Off Operation Stop Remote controller On Off Forced stop Normal CN313 CN314 On On On Indoorunit NOTES When the forced stop is triggered indoor unit stops and Operation Stop operation by the re mote controller is restricted When forced stop function is used with form...

Страница 31: ...Pulse input Function setting Rotary SW on External input and output PCB External input Input signal Command 46 03 1 External input and output PCB CN313 Pulse Operation CN314 Pulse Stop R C disabled On On Off Operation Stop Remote controller On Off Indoor unit CN313 CN314 R C disabled Off On NOTE When Operation Stop mode 2 function is used with forming a remote controller group connect the same equ...

Страница 32: ...ernal input Input signal Command 2 B C External input and output PCB CN313 Off On Thermostat off On Off Normal operation On Off On Off Compressor Room temp Set temp Input 28 9 4 Details of function 9 External input and output WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 33: ... Normal The output is ON when an error is generated for the indoor unit Error Normal On Off CN311 312 Indoor unit Indoor unit fan operation status Rotary SW on External input and output PCB External output Output signal Command 1 External input and output PCB CN312 Off On Fan run On Off Fan stop 2 B D CN311 Off On Fan run On Off Fan stop Output signal Condition On The indoor unit fan is operating ...

Страница 34: ...l input and output PCB External output Output signal Command 2 B C External input and output PCB CN312 Off On Heater on On Off Heater off 30 9 4 Details of function 9 External input and output WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 35: ...e or invalidate of the setting are acceptable 1 External device means Hot water Electrical heater etc 2 Sensor activation Setting change from the factory setting is required Indoor unit fan setting will be on for safety reason without sensor activation of wired remote controller Installation configuration of individual connection External heating device is installed individually No use of indoor u...

Страница 36: ...12 C signal output is on and room temperature Tr increases above 69 8 F 21 C signal output is off and room temperature Tr decreases below 66 2 F 19 C signal output is on and room temperature Tr decreases below 50 F 10 C signal output is off Auxiliary heater control 2 Operation Condition Heater on Heater is on as shown in following diagram of heating temperature Heater off Heater is off as shown in...

Страница 37: ...y function number 62 Operating temperature switching of external heaters All control temperatures will shift by adjusting Thon Tr Room temperature Ts Set temperature Thon Heater on temperature Off On Tr Ts Tr Ts Thon 0 9 F 0 5 C Tr Ts 0 9 F 0 5 C Operation status On 0 9 F 0 5 C 0 9 F 0 5 C On 12 V On Off Off 0 V Off Heating operation Heater Fan Air conditioner Room temperature Set temp 3 min or mo...

Страница 38: ...nction number 62 Operating temperature switching of external heaters All control temperatures will shift by adjusting Thon Outdoor temperature zone boundary A and B Adjustable individually by function setting number 66 and 67 External heater output Tr Room temperature Ts Set temperature Thon Heater on temperature Off On Tr Ts 0 9 F 0 5 C Tr Ts Tr Ts Thon 0 9 F 0 5 C Outdoor temperature zone Heat p...

Страница 39: ...ination zone The outdoor temperature zone transition from one to another will stay in that zone for minimum of 30 min 46 4 F 8 C 42 8 F 6 C 0 4 F 18 C 4 F 20 C NOTE In following operations compressor will be on in heat pump prohibition zone Other than heating Test run 35 9 4 Details of function 9 External input and output WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 40: ...at off Temperature of heater on Thon Adjustable by function number 62 Operating temperature switching of external heaters All control temperatures will shift by adjusting Thon Outdoor temperature zone boundary A Adjustable by function setting number 66 External heater output Tr Room temperature Ts Set temperature Thon Heater on temperature Off On Tr Ts 0 9 F 0 5 C Tr Ts Tr Ts Thon 0 9 F 0 5 C Outd...

Страница 41: ...ne The outdoor temperature zone transition from one to another will stay in that zone for minimum of 30 min 46 4 F 8 C 42 8 F 6 C 0 4 F 18 C 4 F 20 C NOTE In following operations compressor will be on in heat pump prohibition zone Other than heating Test run 37 9 4 Details of function 9 External input and output WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 42: ...by type of the indoor unit For details refer to the operation manual Display panel Mode indicator Clock and Timer indicator SEND indicator Temperature indicator Fan speed indicator Swing indicator Transmit indicator ENERGY SAVING mode indicator LOW NOISE mode indicator Turns on when the SENSOR button is operated Ü To facilitate explanation the accompanying illustration has been drawn to show all p...

Страница 43: ... 124 without batteries Holder Unit in mm 1 15 16 48 5 3 16 5 5 1 1 16 26 2 2 3 4 69 3 1 4 6 5 Front View Side View Bottom View Ø 1 8 Ø3 5 Hole 5 7 8 150 4 3 16 106 8 Hole 1 8 3 5 2 R Size H W D in mm 5 7 8 2 3 4 1 1 16 150 69 3 26 2 Weight oz g 1 27 39 10 1 Wireless remote controller 10 Remote controller WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 44: ...d numbers or setting values are selected When optional wired remote controller is used refer to the installation manual enclosed with the remote controller Entering function setting mode While pressing the POWERFUL button and TEMP button simulta neously press the RESET button to enter the function setting mode Function number Setting value Selecting the function number and setting value 1 Press th...

Страница 45: ...you do not know the air conditioner custom code setting try each of the custom codes until you find the code that operates the air conditioner 41 11 1 Function settings by using remote controller 11 Function settings WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 46: ... A 14 67 Outdoor temperature zone boundary temperature B 15 95 Heat insulation condition building insulation 1 Remote controller address setting NOTE Because this setting is normally done automatically when 2 wire type wired remote con troller is installed setting is unnecessary Multiple indoor units can be operated by using one wired remote controller Set the unit number of each indoor unit Funct...

Страница 47: ... the room temp sensor Correction temp value Example of correction When the temperature of the room temp sensor is 78 F and the setting value is 03 2 F the corrected temp will be 80 F 78 F 2 F The temperature correction values show the difference from the Standard setting 00 manufactur er s recommended value When Function 95 01 High insulation is set the Standard setting 00 will be the same as No c...

Страница 48: ...ling More heating 11 2 F 1 0 C 12 3 F 1 5 C 13 4 F 2 0 C 14 5 F 2 5 C 15 6 F 3 0 C 16 7 F 3 5 C 17 8 F 4 0 C 5 Auto restart Enables or disables automatic restart after a power interruption Function number Setting value Setting description Factory setting 40 00 Enable 01 Disable NOTE Auto restart is an emergency function such as for power outage etc Do not attempt to use this function in normal ope...

Страница 49: ...cription Factory setting 48 00 Both 01 Wired remote controller 10 Indoor unit fan control for energy saving for cooling Enables or disables the power saving function by controlling the indoor unit fan rotation when the outdoor unit is stopped during cooling operation Function number Setting value Setting description Factory setting 49 00 Disable 01 Enable 02 Remote controller 00 When the outdoor u...

Страница 50: ...ting description Factory setting Heater On Heater Off 62 00 5 4 F 3 C 1 8 F 1 C 01 3 6 F 2 C 1 8 F 1 C 02 3 6 F 2 C 1 8 F 1 C 03 5 4 F 3 C 1 8 F 1 C 04 7 2 F 4 C 1 8 F 1 C 05 9 0 F 5 C 1 8 F 1 C 13 Outdoor temperature zone boundary temperature A Setting required if changing of the outdoor temperature setting for heat pump prohibition zone is re quired when auxiliary heater control by outdoor tempe...

Страница 51: ...on 00 allows system to rapidly respond to the cooling or heating load changes High insulation 01 is when the heat insulation structure of the building is high and does not re quire system to rapidly respond to cooling or heating load changes When High insulation 01 is selected Overheating overcooling is prevented at the start up All room temperature control settings Function 30 31 35 and 36 will r...

Страница 52: ...STOP button until only the clock is displayed on the remote controller display 2 Press the MODE button for at least 5 seconds to display the cur rent custom code Initially set to 3 Press the TEMP buttons to change the custom code be tween Match the code on the display to the air con ditioner custom code Initially set to 4 Press the MODE button again to return to the clock display The custom code w...

Страница 53: ...least 5 seconds to display the current temperature unit Factory setting F 2 Press the TEMP buttons to switch the temperature unit between F and C 3 With either of pressing the START STOP button or no additional button operation for 30 sec onds in step 2 the temperature unit currently selected will be set 49 11 3 Switching the temperature unit of remote controller 11 Function settings WALL MOUNTED ...

Страница 54: ...manual 1 Tapping screw large 5 Installation manual 1 Tapping screw small 2 Remote controller 1 Battery 2 Remote controller holder 1 Filter holder 2 Cloth tape 1 Air cleaning filters 1 Wall hook bracket 1 50 12 Accessories WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 55: ... 10 00AM Room Temp Cool Heat Simple remote controller UTY RSRY Compact remote controller concentrates on the basic functions such as Start Stop fan control temperature setting and operation mode Wire type Non polar 2 wire Optional communication kit is necessary for installation Simple remote controller UTY RHRY Compact remote controller concentrates on the basic functions such as Start Stop fan co...

Страница 56: ...ernal input and output PCB UTY XCSXZ2 Use to connect with external devices and air conditioner PCB Optional External connect kit is necessary for installation Communication kit UTY TWRXZ2 Use to connect Non polar 2 core wired remote controller 52 13 2 Others 13 Optional parts WALL MOUNTED ASUG09 15LZAS WALL MOUNTED ASUG09 15LZAS ...

Страница 57: ...Part 2 OUTDOOR UNIT SINGLE TYPE AOUG09LZAS1 AOUG12LZAS1 AOUG15LZAS1 ...

Страница 58: ... 16 632 799 290 Gross 27 1 4 37 14 3 4 692 940 375 Weight Net lb kg 84 38 86 39 Gross 95 43 Connection pipe Size Liquid in mm Ø 1 4 Ø 6 35 Gas Ø 3 8 Ø 9 52 Ø 1 2 Ø 12 7 Method Flare Pre charge length ft m 49 15 Max length 66 20 Max height difference 49 15 Operation range Cooling F C 14 to 115 10 to 46 Heating 5 to 75 21 to 24 Drain hose Material LDPE Tip diameter in mm Ø 1 2 Ø 13 0 I D Ø 5 8 to 11...

Страница 59: ...4 5 16 109 13 7 8 353 24 7 8 632 13 16 20 13 330 Pitch of bolts for installation Pitch of bolts for installation 4 M10 hole Unit in mm Side view Valve part 4 3 4 120 4 1 4 184 7 1 16 180 Bottom view Airflow Drain port Ø1 5 8 42 1 7 16 37 15 11 16 399 Hole Hole Hole 55 2 1 Models AOUG09LZAS1 AOUG12LZAS1 and AOUG15LZAS1 2 Dimensions OUTDOOR UNIT AOUG09 15LZAS1 OUTDOOR UNIT AOUG09 15LZAS1 ...

Страница 60: ...per space is open Unit in mm Obstacles at rear only Obstacles at rear and sides 4 100 or more 10 250 or more 4 100 or more 4 100 or more Obstacles at front Obstacles at front and rear 24 600 or more 24 600 or more 4 100 or more When an obstruction in the upper space Unit in mm Obstacles at rear and above Obstacles at rear sides and above 4 100 or more Max 7 200 24 600 or more 24 600 or more 4 100 ...

Страница 61: ... When an obstruction in the upper space When the upper space is open Unit in mm Obstacles at rear only Obstacles at front only 10 250 or more 8 200 or more 10 250 or more 40 1 000 or more Obstacles at front and rear 10 250 or more 8 200 or more 40 1 000 or more When an obstruction in the upper space Unit in mm Obstacles at rear and above 10 250 or more 10 250 or more 60 1 500 or more 60 1 500 or m...

Страница 62: ... unit in two stage where the drain water could freeze Otherwise the drainage from the upper unit may form ice and cause a malfunction of the lower unit When the outdoor temperature is 32 F 0 C or less do not use the accessory drain pipe and drain cap If the drain pipe and drain cap are used the drain water in the pipe may freeze in extremely cold climate For reverse cycle model only In area with h...

Страница 63: ...ling Heating ThD ThR ThO ThHO Muffler Accumulator ThPI ThC Thermistor Discharge temperature Thermistor Outdoor temperature Thermistor Heat exchanger out temperature ThD Thermistor Compressor temperature ThC ThO ThHO Thermistor Room temperature Thermistor Pipe temperature ThR ThPI 59 4 1 Models AOUG09LZAS1 AOUG12LZAS1 and AOUG15LZAS1 4 Refrigerant circuit OUTDOOR UNIT AOUG09 15LZAS1 OUTDOOR UNIT AO...

Страница 64: ...5 Wiring diagrams 5 1 Models AOUG09LZAS1 AOUG12LZAS1 and AOUG15LZAS1 60 5 1 Models AOUG09LZAS1 AOUG12LZAS1 and AOUG15LZAS1 5 Wiring diagrams OUTDOOR UNIT AOUG09 15LZAS1 OUTDOOR UNIT AOUG09 15LZAS1 ...

Страница 65: ... 992 0 964 0 899 0 895 0 0 1 025 1 000 0 971 0 906 0 902 Indoor unit is lower than outdoor unit 2 5 16 1 025 1 000 0 971 0 906 0 902 7 5 25 1 000 0 971 0 906 0 902 10 33 0 971 0 906 0 902 15 49 0 906 0 902 HEATING Pipe length m 5 7 5 10 15 20 ft 16 25 33 49 66 Height difference H Indoor unit is higher than outdoor unit 1 15 49 0 933 0 925 10 33 0 981 0 933 0 925 7 5 25 1 000 0 981 0 933 0 925 5 16...

Страница 66: ... 982 7 5 25 1 000 0 995 0 983 0 982 10 33 0 995 0 983 0 982 15 49 0 983 0 982 HEATING Pipe length m 5 7 5 10 15 20 ft 16 25 33 49 66 Height difference H Indoor unit is higher than outdoor unit 1 15 49 0 994 0 979 10 33 1 012 0 994 0 979 7 5 25 1 000 1 012 0 994 0 979 5 16 0 969 1 000 1 012 0 994 0 979 0 0 0 969 1 000 1 012 0 994 0 979 Indoor unit is lower than outdoor unit 2 5 16 0 964 0 995 1 007...

Страница 67: ...0 g m m 15 or less 20 Max Additional charge oz 0 3 5 g 0 100 7 2 Model AOUG15LZAS1 Refrigerant type R410A Refrigerant amount lb oz 2 lb 16 oz g 1 350 Refrigerant charge Total pipe length ft 49 or less 66 Max 0 22 oz ft 20 g m m 15 or less 20 Max Additional charge oz 0 3 5 g 0 100 63 7 1 Models AOUG09LZAS1 and AOUG12LZAS1 7 Additional charge calculation OUTDOOR UNIT AOUG09 15LZAS1 OUTDOOR UNIT AOUG...

Страница 68: ...s 514 CFM 1 089 Heating Airflow m3 h 1 850 l s 514 CFM 1 089 8 2 Model AOUG12LZAS1 Cooling Airflow m3 h 1 990 l s 553 CFM 1 171 Heating Airflow m3 h 1 850 l s 514 CFM 1 089 64 8 1 Model AOUG09LZAS1 8 Airflow OUTDOOR UNIT AOUG09 15LZAS1 OUTDOOR UNIT AOUG09 15LZAS1 ...

Страница 69: ...8 3 Model AOUG15LZAS1 Cooling Airflow m3 h 2 070 l s 575 CFM 1 218 Heating Airflow m3 h 2 290 l s 636 CFM 1 348 65 8 3 Model AOUG15LZAS1 8 Airflow OUTDOOR UNIT AOUG09 15LZAS1 OUTDOOR UNIT AOUG09 15LZAS1 ...

Страница 70: ...cy Hz NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Model AOUG12LZAS1 Cooling 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0 dB 0 0002 μbar Octave band center frequency Hz NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 Heating 0 10 20 30 40 50 60 70 80 63 125 250 500 1 000 2 000 4 000 8 000 Octave band s...

Страница 71: ...00 1 000 2 000 4 000 8 000 Octave band sound pressure level dB 0 dB 0 0002 μbar Octave band center frequency Hz NC 65 NC 60 NC 55 NC 50 NC 45 NC 40 NC 35 NC 30 NC 25 NC 20 NC 15 9 2 Sound level check point 40 in 1 m Microphone Microphone Rear Airflow Rear view Side view NOTE Detailed shape of the actual outdoor unit might be slightly different from the one illustrated above 67 9 1 Noise level curv...

Страница 72: ...imum Circuit Ampacity Calculation based on UL60335 2 40 2 Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005 As the regulations of wire size and circuit breaker differ in each country or region select appropriate de vices complied to the regional standard 3 Maximum Circuit Breaker 4 Limit voltage drop to less than 2 If voltage drop is 2 or more increase cable condu...

Страница 73: ... restart Compressor protection Thermal protection program Compressor temp Activate 226 F 108 C Compressor stop Reset After 3 minutes and 176 F 80 C or less Compressor restart Thermal protection program Discharge temp Activate 230 F 110 C Compressor stop Reset After 7 minutes Compressor restart Thermal protection program Outdoor temp Only in COOL and DRY mode Activate 5 F 15 C Compressor stop Reset...

Страница 74: ...12 Accessories Part name Exterior Q ty Part name Exterior Q ty Installation manual 1 Cable tie 2 Drain pipe 1 Drain cap 5 70 12 Accessories OUTDOOR UNIT AOUG09 15LZAS1 OUTDOOR UNIT AOUG09 15LZAS1 ...

Отзывы: